EEWORLDEEWORLDEEWORLD

Part Number

Search

LP202428

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector    terminals   
File Size2MB,6 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

LP202428 Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

LP202428 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberLP2
Installation typeBOARD
Number of layers1
Rows1
Number of channels28
Rated current30 A
Rated voltage150 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
MAGNUM
®
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
A20510807WR
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
.375” or 3/8” (9.52 mm)
LP202110
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc plated philslot
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature
: 105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL/CSA; IEC Compliance;
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
CB20210507
A2000 & LP2000 Series
.375
(9.53)
.15
(3.8)
dia.
.65
(16.5)
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.38
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
C
Mount End
Barrier End
Base & Rail Mount
Connectors
.76 (19.3)
.40
(10.2)
.565 (14.35)
on LP2000
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB2000 Series
.19
(4.8)
dia.
Power Distribution Blocks
.375
(9.53)
.70
(17.8)
.32
(8.1)
Mount End
C
Barrier End
.60
(15.2)
WIRE MANAGEMENT PRODUCTS
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
6
How long does it take to learn FPGA from scratch and be able to do simple programming?
The project requires me to learn FPGA. I have been exposed to Verilog in school before. I have no memory of it. I have been using C since I started working. I have learned Java and web programming for...
ienglgge FPGA/CPLD
Moderator, please help me find out why the application written through IAP cannot run
Help me seeIAP.rar (383.54 KB)Downloads:9 2010-7-19 10:45IO.rar (373.27 KB)Downloads:2 2010-7-19 10:45...
zbashore stm32/stm8
How to use PT2262 and 72 pairs in wireless?
The carrier frequency is required to be less than 30M...
os_mcu_i RF/Wirelessly
Questions about 125KHZ RFID
The 125KHZ RFID reader I made can read everything fine when the crystal frequency is 11.0592MHz, but when I increase the crystal frequency to 18.432MHz, it can no longer read. I really want to ask for...
李俊锋 51mcu
ucos simple multitasking, failed to execute
[i=s] This post was last edited by lw3968 on 2014-9-25 21:08 [/i] [size=5] I recently learned ucos and made a slight change to the code in the book, but there was no multi-tasking (confused): The code...
lw3968 Real-time operating system RTOS
How to configure the timer to trigger AD conversion in 28377
I am going to use 28377 to write a timer 0 to trigger an AD conversion in the ADCA module, and set the ADCINT1 flag to 1 after the soc0 conversion is completed; however, the program I wrote can enter ...
gezheng Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1721  693  1527  549  169  35  14  31  12  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号