EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375C02W-49-1D

Description
Mains Power Connector, 2A, 125/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375C02W-49-1D Overview

Mains Power Connector, 2A, 125/250VAC, Male, Socket

HGN-375C02W-49-1D Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
Base Number Matches1
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
Texas Instruments - Using an Op Amp as a Comparator - Is It Possible?
[i=s]This post was last edited by dontium on 2015-1-23 12:47[/i] [color=#000000][font=宋体][size=12pt]Many people occasionally use op amps as comparators. Generally speaking, this works when you just ne...
德州仪器 Analogue and Mixed Signal
After 220VAC is converted to 15VDC and a load is added, the output voltage is incorrect. What component problem could this be?
Using DM0265R, the 15V output is correct when no load is applied, but after adding load (a motor), the 15V output becomes more than 3V. The problem is that some boards are good, while others are fault...
ldsheng Power technology
MCU selection
For the selection of MCU , SCT12 2052/4052 can be used for learning , which is easy to program. If you want to make a micro-power-saving sparrow type, you can choose the MSP430 series....
bjwl_6338 DIY/Open Source Hardware
Director Tony Testa teaches you how to design products for Wi-Fi 6
[i=s]This post was last edited by alan000345 on 2019-11-28 09:21[/i]Do you know how to design applications for Wi-Fi 6?Experts who support Wi-Fi point out that the launch of the Wi-Fi 6 standard will ...
alan000345 RF/Wirelessly
Group G Code
[i=s] This post was last edited by paulhyde on 2014-9-15 03:27 [/i] I can't understand the code I bought on Taobao. Please share it with me....
奋斗了 Electronics Design Contest
C language topic - standard library
[b]1 Trigonometric functions[/b] double sin (double); double cos (double); double tan (double); [b]2 Inverse trigonometric functions[/b] double asin (double); result is between [-PI/2, PI/2] double ac...
wonderto Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2307  1538  660  1461  1696  47  31  14  30  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号