EEWORLDEEWORLDEEWORLD

Part Number

Search

6135C146F080C0.0310

Description
Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size717KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

6135C146F080C0.0310 Overview

Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

6135C146F080C0.0310 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings10/15A, 250VAC
Manufacturer's serial number6135
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules without line filter
www.schurter.com/PG05
IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole
6135
C14
70° C
Description
- Panel Mount:
Snap-in version from front side
- 2 Functions:
Appliance Inlet, Protection class I, Circuit breaker type TA35, 2-pole
- Quick connect terminal 6.3 x 0.8 mm
Characteristics
- Unwired
- Switch non-illuminated or illuminated
Thermal overload protection
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
Approvals
- VDE Certificate Number: 40023066
- UL File Number: E96454
- Pre-wired version
- Quick connect terminals 4.8 x 0.8 mm
- Protection class II, 70°C
References
Weblinks
Alternative: version for 16 A (20 A)
6136
Substitute for type
7764
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Mounting instruction, Detailed request for
product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 60 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Snap-in1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
C14 acc. to IEC 60320
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or
non-illuminated.
Conditional short circuit Inc:
2000 A
Circuit Breakers
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Connectors
1
oledb problem, urgent!
Hey guys, why does the program hang inside the IDBInitialize::Uninitialize function when I call it, and not complete the function? According to the instructions on MSDN, I released all the pointers, b...
jansionchang Embedded System
Serial Communication Programming Encyclopedia.pdf
Serial Communication Programming...
江汉大学南瓜 51mcu
Quick Start Guide for SI4463 Module with WDS
[i=s]This post was last edited by Chengdu Yibite on 2021-5-13 11:04[/i]1. Introduction Wireless Development Suite (WDS) is a computer terminal software provided by Silicon Labs for configuration and d...
成都亿佰特 RF/Wirelessly
STM32F407VET6 PWM mutual influence problem
Now the PWM wave comes out.But when it was added to the large program, problems arose. Large program code:I added a timer 4, but the result was wrong. Originally there was only this sentence TIM1_PWM_...
chenbingjy stm32/stm8
Development of an Airborne Three-Phase AC Stabilized Power Supply
Abstract: The development of an airborne three-phase AC stabilized power supply is introduced. The power supply circuit is analyzed, calculated and simulated by computer. High-frequency pulse width mo...
zbz0529 Power technology
Problems with I2C communication of MSP430F2XX series microcontrollers
In the I2C module of USCI, UCB0I2CSA is the Slave Address. The general I2C communication process is the start address + data + (CRC). The master transmission mode response signal can be sent without s...
jeremy9007 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1258  430  1053  1959  1194  26  9  22  40  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号