EEWORLDEEWORLDEEWORLD

Part Number

Search

800-007-06C7-10GY

Description
Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size160KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

800-007-06C7-10GY Overview

Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Plug,

800-007-06C7-10GY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceANODIZED BLACK
Shell materialALUMINUM ALLOY
Housing size7
Termination typeCRIMP
Total number of contacts10
Base Number Matches1
A
B
C
Series 800 Plug Connector
D
E
F
G
H
J
K
L
800-009
Knurled Round
Plug with
Accessory
Thread
M
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Plug Connectors
Compact Size
saves space and
weight. Smaller than other Series 80
plugs, these Series 800 plugs are
suitable for hostile environments and
are watertight when mated.
Two Shell Styles:
Integral platform for
direct shield attachment using
BAND-
IT
®
termination system, or accessory
thread for attaching a strain relief.
Crimp, Rear Release
contact system,
now with #12 and #16 M39029 coaxial
or power contacts.
Two Coupling Nut Styles:
Hex nut
or round knurled nut. Either style is
available with optional wave spring
which helps to prevent the nut from
backing off.
HOW TO ORDER
Sample Part Number
800-006
Series
-06
Shell Style
-06
Standard
Coupling Nut
M
Shell Material / Finish
C
7-10
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes to
specify these contacts:
Z
Shell Key
Position
N
Normal
800-006
Hex Plug with
Banding Platform
-16
Coupling Nut
with Anti-
Decoupling
Wave Spring
800-007
Hex Plug with
Accessory
Thread
5-3
Aluminum / Black Anodize
6-1
M
6-4
Aluminum / Electroless
6-7
Nickel
7-1
NF
7-10
Aluminum / Cadmium with
8-13
Olive Drab Chromate
9-4
ZN
9-19
Aluminum / Zinc-Nickel with
10-26
Olive Drab Chromate
12-2
ZNU
12-37
Aluminum / Zinc-Nickel with
Black Chromate
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Z
Pos. Z
Z1
Stainless Steel / Passivated
Special contacts for
#26 to #30 AWG are
also available. Use the
#23 contacts are packaged following contact codes to
specify these contacts:
with connectors. #16 and #12
contacts must be ordered
G
separately.
Pin
800-008
Knurled Round
Plug with Band
Platform
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-4
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Switching Power Supply Interest Group's 10th Task
Question 09  1. In the waveform of Figure (02) in this article, that is, Figure 4.1 (d) of the “Switching Power Supply Design 3rd Edition”, the areas of parts A1 and A2 are equal. What does the equal ...
maychang Switching Power Supply Study Group
Principle and Application of AD698 LVDT Signal Conditioning Circuit
Abstract: This paper introduces the AD698 linear displacement differential transformer (LVDT) dedicated signal conditioning circuit . The application of AD698 can simplify the circuit design . The wor...
feifei Test/Measurement
Please help me analyze this circuit
Please help me analyze the principle of this circuit....
xiefei Power technology
When using the SPI of the XMEGA C series microcontroller, IF is always not set
Hello everyone, when I use the SPI of XMEGA C series microcontroller, the IF in the STATUS register is not set (SPI works in master mode), and the serial transmission is not completed, which causes th...
kiravsl Microchip MCU
Design of traffic light controller based on single chip microcomputer
Design of a single-chip traffic light controller 1. Design task Set up traffic lights at a crossroads and use a single-chip microcomputer to reasonably control them. Time and direction control require...
1234 MCU
Security e-commerce development has encountered "bumps" How should enterprises solve it
In early July this year, the e-commerce platform "Anfangren Mall" of Shenzhen Yutong, the first professional security e-commerce company in China, launched a small-scale investment promotion. In about...
bjjabq Industrial Control Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1532  2350  339  642  1638  31  48  7  13  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号