EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375C10Q-49-1MM4

Description
Mains Power Connector, 10A, 125/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375C10Q-49-1MM4 Overview

Mains Power Connector, 10A, 125/250VAC, Male, Socket

HGN-375C10Q-49-1MM4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE, QUICK CONNECT
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings10A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
MSP430F5529A interrupts the corresponding program exit
Hi everyone, I'm here to ask stupid questions again. Here is the interrupt response program of the ADC12 multi-channel conversion routine: #pragma vector = ADC12_VECTOR __interrupt void ADC12ISR(void)...
SYW Microcontroller MCU
【Design Tools】Xilinx FPGA Chip Architecture Analysis
Analysis of Xilinx FPGA chip architecture...
nwx8899 FPGA/CPLD
Strong pulse trigger circuit
[img]file:///E:\QQ\76369393\Image\BR4E)~J2{_H_CQ}MV[W4%1Q.jpg[/img][img=0,1]file:///E:\QQ\76369393\Image\BR4E)~J2{_H_CQ}MV[W4%1Q.jpg[/img][img=0,1]file:///E:\QQ\76369393\Image\T12[7HW0Y)]IJMC9GN}_~MM....
wmy10226 Analog electronics
What will you do when you retire?
[i=s]This post was last edited by lugl4313820 on 2022-4-28 20:14[/i]In the evening, I attended an event for retired seniors in the company. Everyone was a little excited. When I retire, what kind of i...
lugl4313820 Talking
STM Series (1): Basic Configuration of STM32/STM8 Hardware Platform
[b][b][color=rgb(31, 130, 175)][font=宋体][size=19px]Question: [/size][/font][/color][/b][/b][p=24, null, left][color=rgb(62, 62, 62)] [/color][/p][align=left][color=rgb(62, 62, 62)]This problem was rai...
月亦雪 Integrated technical exchanges
Model Identification of Several Types of Tape Players
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:58[/i]In the field of Walkman, there are many brands and models. You will benefit a lot from understanding them, so that you can know t...
lorant Mobile and portable

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2277  974  2876  1009  1236  46  20  58  21  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号