EEWORLDEEWORLDEEWORLD

Part Number

Search

FHSC-130-06.00-STL-SBR

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size372KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

FHSC-130-06.00-STL-SBR Overview

Interconnection Device, ROHS COMPLIANT

FHSC-130-06.00-STL-SBR Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
F-210-1 SUPPLEMENT
(1,27mm) .050"
FHSC SERIES
FHSC–125–15.00–SEU–TTR
FHSC–115–10.00–TTL–SED
HIGH SPEED CABLE ASSEMBLIES
SPECIFICATIONS
For complete specifications
see www.samtec.com?FHSC
Cable:
38 AWG coax
micro ribbon
Signal Routing:
50Ω Single-Ended
Overall Length:
(152mm) 6" to
(1m) 40" standard
Cable Flexing Life:
>40,000 cycles
Cable Bending Radius:
<2,5mm
Plating:
Au over 50µ" (1,27µm) Ni
Current Rating:
300 millamp max
Propagation Delay:
4.5 nsec/meter
Operating Temp Range:
-40°C to +105°C
RoHS Compliant:
Yes
-TXX Mates with:
SFM
-SXX Mates with:
TFM
Header or Socket
Termination
Uses
38 AWG
micro ribbon
coax cable
APPLICATION
SPECIFIC
• Other wire AWG
• Hot plugging
• Other lengths
• Other terminations
• Other sizes
Contact asp@samtec.com
(1,27mm)
.050"
pitch
Cable
Length
10" (254mm)
Rated @ 3dB
Insertion Loss
FHSC
175 MHz / 0.35 Gbps
Performance and complete test data
available at www.samtec.com?FHSC
or contact sig@samtec.com
Surface or
Edge Mount (socket only)
APPLICATION
(10,87)
.428
FHSC
1
NO. POSITIONS
PER ROW
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
Processing conditions will
affect mated height.
END TO END
–SM to –SM
–SM to –EM
–EM to –EM
L
(15,24) .600
(19,81) .780
(24,38) .960
05, 10, 15, 20, 25, 30
(Call for other sizes)
OAL = Wire Length +
L
Wire Length
±
(1,27) .050
= Wire Length
in Inches
(152mm) 06.00"
minimum
Specify
END ASSEMBLIES
from chart
–1
= Pin 1 to
Pin 1
–2
= Pin 1 to
Pin 2
Important Note:
For optimal performance,
at least one transmission line
must be dedicated to ground.
For more information, go to
www.samtec.com/cable_
builder/xhsc_grounding.asp
Note:
NO. OF
Contact Samtec
A
POSITIONS
for high
speed
(20,37) .802
–05
characterization.
(28,37) 1.117
–10
Note:
(32,39) 1.275
–15
Cable lengths
(43,36) 1,707
longer than
–20
40.00" (1
(52,37) 2.062
–25
meter) are not
(52,37) 2.062
–30
supported with
S.I. test data.
END
B*
Note:
(
10,24)
Verify part number with
– TXX
.403
Samtec’s Interactive
(
9,22)
Cable Builder at
–SXX
.363
www.samtec.com/
cable_builder/pitch.aspx
* Surface Mount End
Note:
This Series is non-standard,
non-returnable.
Options only.
SURFACE MOUNT
02
01
ASSEMBLY
–TTR
=Terminal,
Top,
Notch
Right
–TTL
=
Terminal,
Top,
Notch
Left
–TBR
=
Terminal,
Bottom,
Notch
Right
–TBL
=
Terminal,
Bottom,
Notch
Left
–STR
=
Socket,
Top,
Notch
Right,
–STL
=
Socket,
Top,
Notch
Left
–SBR
=
Socket,
Bottom,
Notch
Right
01
–SBL
=
Socket,
Bottom,
Notch
Left
END 1
30
30
END 2
30
30
–3
= Pin 1 to
Second
Last Pin
–4
30
30
30
30
30
30
30
30
= Pin 1 to
Last Pin
A
WIRING REQUIREMENTS
WIRING
END OPTIONS
OPTION
30
02
(7,67)
.302
30
30
30
1 or 2
EDGE MOUNT
B*
TTR, TBL, STL, SBR, SED to
TTR, TBL, STL, SBR, SEU
or
TTL, TBR, STR, SBL, SEU to
TTL, TBR, STR, SBL, SED
TTR, TBL, STL, SBR, SED to
TTL, TBR, STR, SBL, SED
or
TTL, TBR, STR, SBL, SEU to
TTR, TBL, STL, SBR, SEU
ASSEMBLY
–SEU
=
Socket,
Edge,
Notch
Up
–SED
=
Socket,
Edge,
Notch
Down
END 1
30
END 2
30
3 or 4
END NO. 1
END NO. 2
30
30
WWW.SAMTEC.COM
Application of electronic superconducting solid-state relays in constant temperature control systems
[color=rgb(96, 96, 96)][backcolor=rgb(255, 255, 255)][font=Arial, Helvetica, sans-serif][size=12px][font=宋体] In the existing constant temperature control system in my country, solid-state relays[/font...
zuoyoudianzi Industrial Control Electronics
Grounding Concepts 1
Complete Concept of Grounding 1. AC grounding: refers to only allowing AC signals to flow to the ground wire, and not allowing DC current to pass through. For example, decoupling and filter capacitors...
fighting Analog electronics
【XMC4800 Relax EtherCAT Kit Review】+Detailed tutorial for new DAVE projects
Here I use a timer, interrupt, and digital IO to create a project. 1. Open DAVE and enter the workspace. It is best to use different workspaces for different versions. 396706 396707 396708 396709 3967...
anger0925 Industrial Control Electronics
Software simulation debugging issues of CCS
I want to debug a program with software simulation. I want to see the output of the T1 PWM pin of the 2812. How can I check it? Some experts said to assign the pin value to a variable. How can I assig...
zhangyy901 DSP and ARM Processors
The main differences between routers and switches are as follows:
The main differences between routers and switches are as follows:(1) Different working levels The original switch worked at the data link layer of the OSI/RM open architecture, which is the second lay...
eeleader Industrial Control Electronics
13-TCP protocol (FIN_WAIT2)
[b]1. FIN_WAIT2 state[/b][p=26, null, left][color=rgb(79, 79, 79)][font=-apple-system, "]If you have completed the experiment in the previous article, you must have seen the FIN_WAIT2 state.[/font][/c...
兰博 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2839  602  2421  2303  2706  58  13  49  47  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号