Tantalum Surface Mount Capacitors – MIL-PRF (CWR Series)
Table 1 – T409 Series CWR09 Style MIL-PRF 55365/4, Ratings & Part Number Reference
Rated
Voltage
85ºC
VDC
4
4
4
4
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
VDC
85ºC
Rated
Cap
120Hz
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
µF
120Hz
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
(see below for
part options)
MIL-C-55365/4F
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
(See below for
part options)
DC
Leakage
µAmps +20ºC
max/5min
0.1
0.2
0.3
0.4
0.6
1.3
2.7
4.0
0.1
0.2
0.3
0.4
0.6
1.4
3.0
4.3
0.1
0.2
0.3
0.5
0.7
1.5
3.3
4.7
0.1
0.2
0.3
0.5
0.7
1.5
3.3
5.0
0.1
0.1
0.2
0.3
0.4
0.7
1.4
3.0
4.4
0.1
0.2
0.3
max/5min
µAmps +20ºC
DF
+20ºC 120Hz
% Max
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% Max
+20ºC 120Hz
ESR
+20ºC 100kHz
Ohms
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
Ohms
+20ºC 100kHz
Moisture
Sensitivity
Temp≤260ºC
J-STD-020D
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
J-STD-020D
Temp≤260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-C-55365/4F
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ± 20%, K for ± 10%, or J for ± 5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert B (0.1%/1000Hrs), C (0.01%/1000Hrs), D (0.001%/1000Hrs) or A = N/A. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates Surge current
option.
Refer to Ordering Information for additional detail.
There are not many debugging tools available for RSCV microcontrollers. For GD32VF103, only gd-link is recommended by the manufacturer. Here I would like to share with you a simple way to use the FT23...
Many battery-powered applications require a buck converter to operate at 100% duty cycle, where V IN is close to V OUT , to extend battery life when the battery voltage reaches its minimum value.
For ...
Divide the program into two projects, namely the BOOT boot program and the user program. The boot program is stored in a separate sector, and the user program is stored in another sector. After the bo...
I need to use JLINK recently, but I only have one STLINKV2, so I made a small JLINK board according to the method of the forum master [url]https://bbs.eeworld.com.cn/forum.php?mod=viewthread&tid=45841...
[i=s]This post was last edited by sylar^z on 2020-6-11 17:25[/i]The recording function of LIS25BA mainly includes the following parts. The first part is the audio acquisition function of LIS25BA, whic...
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
There are many different ways of human-computer interaction. The more common ones are listed below:
Mouse interaction: Using a mouse to operate a computer and interact was the most common human...[Details]
The intelligent driving community has its own rhythm. Some are busy pushing new versions and focusing on R&D, others are busy with publicity and promotion, and still others are immersed in mass pro...[Details]
New energy vehicles are increasingly popular with consumers due to policies and energy conservation. Once you've purchased your vehicle, maintenance is essential. However, due to the different powe...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
As the scale and business applications of national e-government networks continue to expand, the data and services transmitted over them are becoming increasingly sensitive and critical. To protect...[Details]
The digital TV set-top box consists of a tuner, QAM demodulator, TS demultiplexer, MPEG-2 decoder, PAUNTSC video encoder, embedded CPU system and peripheral interfaces, CA module, and uplink data m...[Details]
Normally, we determine our location and where we want to go by comparing our surroundings with observation and simple GPS tools. However, this kind of reasoning is very difficult for self-driving c...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
MQTT Ethernet I/O modules primarily collect I/O port information and transmit data over the network. In addition to being a TCP server, Ethernet I/O modules can also function as TCP clients. Furthe...[Details]
Common methods for troubleshooting roller press bearing wear include repair welding, thermal spraying, brush plating, and scrapping and replacement. However, these methods are often subject to asse...[Details]
The driving mode is not unfamiliar to vehicles. According to the driving mode of the vehicle, there are front-wheel drive, rear-wheel drive and even four-wheel drive. Four-wheel drive is a major se...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
As a pioneer in the new smart home concept, robot vacuums have captured a significant market share. Robot vacuums, also known as automatic sweepers, smart vacuums, or robot vacuums, are smart home ...[Details]