EEWORLDEEWORLDEEWORLD

Part Number

Search

8D0-09W35BA022

Description
MIL Series Connector, 6 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size692KB,12 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

8D0-09W35BA022 Overview

MIL Series Connector, 6 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

8D0-09W35BA022 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerEsterline Technologies Corporation
Reach Compliance Codenot_compliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-38999, EMI SHIELDED, POLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Environmental characteristicsENVIRONMENT/FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceCADMIUM PLATED
Shell materialALUMINUM ALLOY
Housing size9
Termination typeCRIMP
Total number of contacts6
Base Number Matches1
8D Series
D38999 Aluminum Series
Connector part numbers
Basic Series
8D
0
-
1
1
W
35
P
N
Shell style:
0:
Square flange receptacle
1:
In line receptacle
7:
Jam nut receptacle
5: Plug with RFI shielding
Also available:
.
Square flange receptacle with clinch nuts (see page 80)
.
Jam nut receptacle with double flange (see page 83)
Type:
None:
Connectors with standard crimp contacts.
L: Receptacle with long PC tail (male and female size #22D, #20).
C: Receptacle with short PC tail (male and female #22D, #20, #16).
S: Receptacle with specific PC tail (male et female #22D)
W: Receptacle with male contacts #22D for wire wrap (3 wraps)
T:
Receptacle with male contacts #20 for wire wrap (2 wraps)
P:
Receptacle with solder cup - only available for Reinforced sealing Series (see
page 75) - male and female size #22D; male #16 & #1
2; female #16 & #1
2
and male female #20 please consult us
Shell size: 09, 1 , 1 15, 1 1 21 23, 25
1 3,
7, 9, ,
Plating:
W:
Olive drab cadmium
F: Nickel
ZC:
Green zinc cobalt
Z: Black zinc nickel
Contact layout:
See pages 1 to 16
3
Contact type:
P:
Pin
A:
Connector supplied less pin contact or with specific contacts (connector marking: A + orientation)
S:
Socket
B:
Connector supplied less socket contact or with specific contacts (connector marking: B + orientation)
Orientation: N, A, B, C, D, E
(see page 64)
Specification:
046:
Tinned straight PC tail
251:
Connector provided with power contacts (layouts with contact #8)
022: Fuel tank
Special custom:
None:
Standard plastic cap
M:
Antistatic plastic cap
L: For P or S contact type only, connectors delivered without contacts, connectors marking P or S plus orientation
-
-
L
22
In PADS95, how to add suffixes to the reference numbers of components in batches?
See the attached picture. Now I want to add the suffix A to the reference numbers of all components (e.g., change R2 to R2_A, change C1 to C1_A, etc.). How can I modify this in batches in pads95? Than...
yhye2world PCB Design
How to generate .r43 library files
I want to make my own C function into a .r43 library file, but I don't know how to use it for MSP430 microcontroller programming...
climbar Embedded System
SHLoadImageFile failed to load local ico image
I want to load an ico image from a file. I used the SHLoadImageFile function. GetlastErr is 6 and it always fails to load. I also used LoadImage and it reported error 1814. Now I don't know what to do...
nywl Embedded System
About the calculation of msp430g2553
[align=left][color=rgb(85, 85, 85)][font="][size=14px]This is a very simple code. It is to separate the numbers of each digit in f. Why is the result I get wrong with this method? I think the method i...
pcb研发中心主任 Microcontroller MCU
Lack of thermal analysis puts your design efforts at risk
Remember when thermal analysis meant pulling back prototypes and figuring out if you needed to add two extra heat sinks and a fan? Try that approach now and you’ll find yourself in a quagmire with no ...
征服 PCB Design
Switching power supply testing "Five rules"
[b]Repeated short circuit test[/b] Test description: Under various input and output conditions, the module output is short-circuited, and the module should be able to achieve protection or retraction....
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1617  1237  534  1176  647  33  25  11  24  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号