SDR250AS12-F

Description
AC-DC Power Supplies
File Size12MB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet View All

SDR250AS12-F Overview

AC-DC Power Supplies

AC-DC
250 Watts
SDR Series
3.2”x 5”Footprint
Fits 1U Applications
Low Leakage Current
Up to 600 W Peak Power
Single & Dual Outputs
xppower.com
Top Fan & Convection-cooled Versions
3 Year Warranty
Specification
Input
• 90-132 VAC/180-264 VAC,
auto ranging
Input Frequency
• 47-63 Hz
Input Current
• 6 A at 115 VAC, 3 A at 230 VAC
Inrush Current
• Max 70 A at 230 VAC, 35 A at 115 VAC,
cold start at 25 °C
Power Factor
• EN61000-3-2, class A
Earth Leakage Current
• <500 µA at 264 VAC/50 Hz
Input Protection
• Internal T8A/250 V fuse in line
Input Voltage
General
Efficiency
• Single output models: 3.3 V & 5 V models
70%, 12 V models 80%, all other models
>83% at 230 V & full load. Dual output
models: >70% at 230 V & full load
• 3000 VAC Input to Output
1500 VAC Input to Ground
100 VDC Output to Ground
• 29 kHz typical
• 10.4 W/in
3
• Power Good TTL HIGH within
100-500 ms and LOW ≤1 ms before loss
of regulation
• 150 kHrs typical to MIL-HDBK-217F
at 25 °C, GB
Isolation
Switching Frequency
Power Density
Signals
Output
• See tables
• ±5% on V1 (V2 of dual output models will
track by same % of adjustment)
Initial Set Accuracy
• ±1%
Minimum Load
• 1% on single output models,
10% on both outputs for dual models
Start Up Delay
• 1.5 s max at 120 VAC
Start Up Rise Time
• 50 ms typical
Hold Up Time
• 20 ms min at 80% of full load
Line Regulation
• ±0.5%
Load Regulation
• ±1% 1-100% load for single outputs
±3% V1, ±7% V2 for dual outputs
(except 0312 & 0512 models, ±10%
regulation on V2)
Over/Undershoot
• 5% max
Transient Response
• 5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (see note 3)
Overvoltage Protection
• <130% Vnom on output V1,
recycle input to reset
Overtemperature
• Measured internally with auto recovery
Protection
Overload Protection
• 110-140%
Short Circuit Protection
• Trip & restart (hiccup mode),
auto recovery
Remote On/Off
• Requires a low signal to inhibit output
(hiccup mode)
Fan Supply
• 12 VDC, 300 mA, not available on
‘-F’ version with built-in fan
Output Voltage
Output Voltage Trim
MTBF
Environmental
Operating Temperature
• 0 °C to +70 °C, derate at 2.5%/ °C from
+50 °C to +70 °C for single output &
forced air cooled dual output models.
For convection cooled dual output
models, (see note 7)
Storage Temperature
• -20 °C to +85 °C
Operating Humidity
• 5-90%, non-condensing
Storage Humidity
• 5-90%, non-condensing
Cooling
• ‘-F’ version has built-in fan, others require
16 CFM to meet forced air ratings
Operating Altitude
• 3000 m
Vibration
• 5-50 Hz, acceleration 7.35 m/s
2
on
X, Y and Z axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
EN55022 level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 3V Perf Criteria A
• EN61000-4-11 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• UL60950-1, CSA C22.2 No. 950,
EN60950-1

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 621  2718  162  1858  2213  13  55  4  38  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号