EEWORLDEEWORLDEEWORLD

Part Number

Search

5424.2253.253

Description
Mains Power Connector, 2A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size403KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5424.2253.253 Overview

Mains Power Connector, 2A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT

5424.2253.253 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderFEMALE AND MALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings2A, 250VAC
Manufacturer's serial number54
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts6
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54
Standard- or Medical-Filter
Snap-In Version
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
Description
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fu-
seholder for fuse-links 5␠x␠20␠mm 1␠ or 2␠pole, Line filter in standard
and medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Characteristics
Approvals
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
- VDE Certificate Number: 101307
- UL File Number: E72928
Other versions on request
References
Weblinks
- Line switch with other rocker marking
Alternative: version without line filter
Felcom 64
Alternative: Standard version
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.
5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC 60320,
F acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
10 A, Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, UL 1283,
CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Connectors
1
Infineon Brushless Motor
[size=5][b]Discussion based on the course Infineon's new 12V brushless DC motor demonstration system introduction [url=https://training.eeworld.com.cn/course/1965]https://training.eeworld.com.cn/cours...
jh2014cj Industrial Control Electronics
Bearded Man
The new internet celebrity, the bearded man, has received over 130,000 hits on one post , (PS) there are over 700 pictures, this is the original photo...
gaoyanmei Talking
Multi-core DSP application market
[size=3][color=#252525]3G Mobile Communications[/color] [color=#252525] One of the most important application areas of multi-core DSP is 3G digital mobile communications. This includes applications in...
Jacktang DSP and ARM Processors
Car maintenance is not just a fantasy. Don't be impatient when replacing parts.
Just like an old policeman can tell who has "three hands" on a bus at a glance, an experienced repair shop clerk can also tell whether you are a rookie from your words and deeds. Mr. Liu bought his ca...
村口的大爷 Automotive Electronics
filesys.exe Errors
OEMEnumExtensionDRAM:No Extended RAM, RAM size is 128 MB Sp=ffffc7cc Data Abort: Thread=87f6c8a4 Proc=81e9e950 'filesys.exe' AKY=00000003 PC=81b38454(NK.EXE+0x00038454) RA=00000001(???+0x00000001) BVA...
jincheng702 Embedded System
Simulation and Calculation in PCB Circuit Design
There are many different types of simulation software on the market, all of which are helpful to PCB designers. Each tool has its own capabilities and limitations, and understanding their basic charac...
btty038 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1102  2901  1869  2252  2405  23  59  38  46  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号