EEWORLDEEWORLDEEWORLD

Part Number

Search

LK2660-7ED4TB2

Description
AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size1MB,26 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LK2660-7ED4TB2 Overview

AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE

LK2660-7ED4TB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Other features24V ADDITIONAL OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage310 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage24.14 V
Minimum output voltage23.86 V
Nominal output voltage24 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
Cassette Style
AC-DC Converters
K Series
150 Watt AC-DC (DC-DC) Converters
for 400 Hz Mains
Input voltage range from 85...255 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
• Input frequency range 47...440 Hz
• No PFC
Extremely wide input voltage range
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K series of AC-DC (DC-DC) converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include wide input frequency
range (no PFC), high efficiency, high reliability, low output
voltage noise and excellent dynamic response to load/line
changes.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Certain types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
All outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal ap-
plied to the connector pin 18 (i). If the inhibit function is not
used pin 18 must be connected to pin 14 to enable the out-
puts.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) und UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds the
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
For applications with requirements for com-
pliance with IEC/EN 61000-3-2 (harmonic distortion)
please use our LK 4000 and LK 5000 series.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 20
Accessories .................................................................... 26
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 5
Auxiliary Functions ......................................................... 10
Edition 5/5.2000
1/26
51 Minimum System
I soldered a 51 minimum system myself. The program downloaded and downloaded by the chip on the development board can be used. But when it is placed on the one I made, there is no delay effect. There ...
xionglan 51mcu
Help: ad9244 keeps smoking~~
At first, AD9244 worked fine, but after a while, it started to smoke. What's going on? I made the same board twice, in the same PCB processing factory. The first time it was fine, but the second time ...
john_wang Analog electronics
Problems with building long-distance networks with low-power nodes
It is now possible to connect low-power nodes to the Internet using a variety of wireless technologies.Among all wireless technologies, using the Sub-1 GHz band for communication can achieve the longe...
Aguilera RF/Wirelessly
Raw OS is a simulation environment based on vc++
Raw OS is a simulation environment based on vc++...
凌海滨 Embedded System
The feasibility of parallel connection of operational amplifiers
Is it possible to connect op amps in parallel to double the output current? Every once in a while, I see questions like this on the E2E forum. Although we'll reply in the affirmative, it's enough to s...
maylove Analogue and Mixed Signal
Code for "MCU C Language Programming and Examples"
[i=s] This post was last edited by paulhyde on 2014-9-15 09:27 [/i] I hope it will be helpful to your study~~~...
xianghong123 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2643  1398  1519  2459  1887  54  29  31  50  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号