Part Number

Search

FLR300-B1C80SB3

Description
Multi-Delay Relay, DPDT, Momentary, 32VDC (Coil), 2A (Contact), 28VDC (Contact), 80s, AC/DC Output, Socket Mount,
CategoryMechanical and electronic products    relay   
File Size492KB,8 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

FLR300-B1C80SB3 Overview

Multi-Delay Relay, DPDT, Momentary, 32VDC (Coil), 2A (Contact), 28VDC (Contact), 80s, AC/DC Output, Socket Mount,

FLR300-B1C80SB3 Parametric

Parameter NameAttribute value
MakerEsterline Technologies Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPANEL MOUNTABLE
body width13.3 mm
body height28.6 mm
Body length or diameter26 mm
Maximum coil voltage (DC)32 V
Contact (AC) maximum rated R load.3A@115VAC
Maximum contact current (AC)0.3 A
Maximum contact current (DC)2 A
Contact (DC) maximum rated R load2A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay80 s
JESD-609 codee3
Installation featuresSOCKET MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
physical size26mm x 13.3mm x 28.6mm
Relay actionMOMENTARY
Relay functionDPDT
Relay typeMULTI-DELAY RELAY
sealHERMETICALLY SEALED
surface mountNO
Terminal surfaceTIN
Termination typeSNAP-ON
FLR300
ENGINEERING DATA SHEET
TIME DELAY RELAY
2 PDT, 2 AMP
Time delay relay (on operate, on release or repeat cycle timer)
Fixed or adjustable timing delay
Contact arrangement
Power supply
2 PDT
Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions of case
2 Amps / 28 Vdc
< 40 grams
44mm x 28.6mm x 13.3mm max
Tin plated hermetically sealed metal can.
APPLICABLE SOCKETS:
S300
S302
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
100,000 cycles
100,000 cycles
500,000 cycles
100 cycles
Contact rating per
pole and load type
resistive load
inductive load (L/R=5ms)
low level (30µA/30mV max)
resistive overload
Load Current in Amps
@28VdC
2
0.75
-
4
@115Vac/60-400Hz
0.3
-
-
-
NUMBERING SYSTEM
FLR300 - B
4
A
0.1s
A
1
Basic series designation___________________|
|
|
|
|
|
|
1-Mounting Styles (A,B,C,D,J)______________________|
|
|
|
|
|
2-Terminal Types (1,2,4)_______________________________|
|
|
|
|
3-Types Of Operation (A,B,C)__ ____________________________|
|
|
|
4-Time range (1,2,3,4) or fixed time in s _______________________|
|
|
5-Temperature Range (A,B) ____________________________________________|
|
6-Accuracy (1,2,3) ________________________________________________________|
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 3/06
- 57 -
Page 1 of 4
Decoupling Technology
Attached is the technical document "Decoupling Technology" from Analog. Highlights: 1. In addition to the ESL and ESR we usually see, the equivalent circuit model of the capacitor also adds the insula...
nathanzhang Analog electronics
Antenna far-field pattern measurement steps example [E]
1. Pattern measurement:a. The anechoic chamber is a far-field measurement system with size of7m*3m*3m. The quiet zone region is 30cm x 30cm x 30cm at center ofthe rotator.b. The probing antenna is the...
fly RF/Wirelessly
How to calibrate 430 using IAR
The manual says that the maximum frequency of g2553 is 26mhz, so how to set its frequency? BCSCTL1 = CALBC1_16MHZ; DCOCTL = CALDCO_16MHZ; I use the above code, why does it compile incorrectly? Please ...
无酒亦醉 Microcontroller MCU
No points for now, this post will add points, please ask: How can I install the contents of NETCFv35.wce.armv4.cab in PB? Instead of installing it on the device
The management method of NETCFv35.wce.armv4.cab is to install it on the device, but this method is not advisable for large-scale production. We want to install NETCFv35.wce.armv4.cab directly in PB, s...
WGGIJLCGEQ ARM Technology
Can this circuit run?
D8 in the figure realizes half-wave rectification. Can the solid-state relay also perform zero-crossing detection?...
gsy MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1240  1079  946  33  1256  25  22  20  1  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号