Part Number

Search

BZG05C22-TR3/6

Description
DIODE 22 V, 3 W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE, DO-214AC, ROHS COMPLIANT, PACKAGE-2, Voltage Regulator Diode
CategoryDiscrete semiconductor    diode   
File Size66KB,5 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

BZG05C22-TR3/6 Overview

DIODE 22 V, 3 W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE, DO-214AC, ROHS COMPLIANT, PACKAGE-2, Voltage Regulator Diode

BZG05C22-TR3/6 Parametric

Parameter NameAttribute value
MakerVishay
Parts packaging codeDO-214AC
package instructionR-PDSO-C2
Contacts2
Reach Compliance Codeunknown
ECCN codeEAR99
ConfigurationSINGLE
Diode component materialsSILICON
Diode typeZENER DIODE
JEDEC-95 codeDO-214AC
JESD-30 codeR-PDSO-C2
Number of components1
Number of terminals2
Maximum operating temperature150 °C
Minimum operating temperature-65 °C
Package body materialPLASTIC/EPOXY
Package shapeRECTANGULAR
Package formSMALL OUTLINE
polarityUNIDIRECTIONAL
Maximum power dissipation3 W
Nominal reference voltage22 V
surface mountYES
technologyZENER
Terminal formC BEND
Terminal locationDUAL
Maximum voltage tolerance6%
Working test current10 mA
BZG05C-Series
Vishay Semiconductors
Zener Diodes
Features
High reliability
Voltage range 3.3 V to 100 V
Fits onto 5 mm SMD footpads
Wave and reflow solderable
AEC-101 qualified
Compliant to RoHS directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
15811
Applications
• Voltage stabilization
Mechanical Data
Case:
DO-214AC
Weight:
approx. 77 mg
Packaging codes/options:
TR/1.5K 7" reel
TR3/6K 13" reel 6K/box
Absolute Maximum Ratings
T
amb
= 25 °C, unless otherwise specified
Parameter
Power dissipation
Non repetitive peak surge
power dissipation
Junction temperature
Storage temperature range
Test condition
R
thJA
< 30 K/W, T
amb
= 60 °C
R
thJA
< 100 K/W, T
amb
= 25 °C
t
p
= 100 µs sq.pulse, T
j
= 25 °C
prior to surge
Symbol
P
diss
P
diss
P
ZSM
T
j
T
stg
Value
3
1.25
60
150
- 65 to + 150
Unit
W
W
W
°C
°C
Thermal Characteristics
T
amb
= 25 °C, unless otherwise specified
Parameter
Junction lead
Mounted on epoxy-glass hard
tissue, fig. 1a
Junction ambient
Mounted on epoxy-glass hard
tissue, fig. 1b
Mounted on Al-oxid-ceramic
(Al
2
O
3
), fig. 1b
Test condition
Symbol
R
thJL
R
thJA
R
thJA
R
thJA
Value
30
150
125
100
Unit
K/W
K/W
K/W
K/W
Electrical Characteristics
T
amb
= 25 °C, unless otherwise specified
Parameter
Forward voltage
Test condition
I
F
= 0.2 A
Symbol
V
F
Min.
Typ.
Max.
1.2
Unit
V
Document Number
85595
Rev. 2.0, 24-Aug-10
For technical questions within your region, please contact one of the following:
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
www.vishay.com
1
EMC conducted emission receiver coupling method
ESCI cannot input DC level. The receiver manual will indicate that for DC-coupling, the max. DC voltage is 0 V. Is the EMC conducted emission test voltage AC or DC? If it is AC, what is the frequency?...
嗯哼哼 Test/Measurement
Recommended Classic Materials on Software Testing (XVIII) --- Full Software Testing
[align=center][size=5][font=宋体]Recommendation of Classic Materials on Software Testing (18)[/font][font=Times New Roman]---[/font][/size][font=Helvetica, Tahoma, Arial, sans-serif][size=5][color=#6666...
tiankai001 Download Centre
[Keysight Technologies Thanksgiving Month Essay Contest] Testing life started with Keysight oscilloscopes
Unfortunately, as a hardware development engineer, I never systematically tested a single board in the first three years of my development career. After I said goodbye to my old employer, I started a ...
651076842 Test/Measurement
How to judge whether the serial port data has been sent
In the 430 serial port, there is an R/D control line. When receiving data from the host computer, I don't know whether my own data has been sent. When can I set the R/D bit low to receive data? It see...
jgj Microcontroller MCU
It’s late at night, is there anyone still awake?
[font=Helvetica, Arial, sans-serif][color=#000000][size=12px]It’s late at night, everyone is quiet, and the heart is tired. Is there anyone who hasn’t slept yet? [/size][/color][/font]...
科技变革 Talking
Why can't the LCD display normally after initializing the clock?
I am using MSP430F149. I have never tried to initialize the clock function. A few days ago, I tried to adjust the infrared remote control decoding, but it didn't work. Later, my friend told me to try ...
jndxxhp Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 211  920  1567  2565  1507  5  19  32  52  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号