FES DC-DC Series Data Sheet
Single-Output, 300 Watts
Features
•
•
•
•
•
•
•
•
60A “full-brick”
Very high efficiency
Open-frame packaging
100°C baseplate operation
Planar magnetics
Excellent transient response
1500V isolation
Synchronous rectification
DESCRIPTION
FES single output DC/DC converters provide up to 300 watts of output power and up to 60 amperes of output current
in a full-brick package. The FES converters feature open-frame packaging, along with planar magnetics and a high
efficiency topology, to provide maximum useable power density. The FES converters use 100% surface-mount
construction and are fully compatible with production board washing processes.
Technical Specifications
Input
Voltage Range
48 VDC Nominal
Undervoltage Lockout - Turn on / Turn off
Output
Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
Remote Sense Headroom
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Current Limit Threshold Range, % of I
out
Rated
OVP Trip Range
OVP Type
Short Circuit/Over Current Protection
General
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF
†
(Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
10 ms
Positive Logic
V
in
Negative
200 or 300 kHz
1500 VDC
1050 VDC
500 VDC
0.03%/°C
-40 To +100°C
-40 To +125°C
105 To 125°C
5 g, 10 - 55 Hz
Consult Factory
UL, cUL, TUV
4.4 oz
±1%
0.2% V
out
0.2% V
out
0.5 VDC
10 % I
out
Rated
25% I
out
4% V
out
500
µs
±10%
110 - 140%
120 - 140% V
out
Nom.
Self Recovering
Shutdown/Hiccup
36 - 75 VDC
34 / 32 VDC
Efficiency vs. Load (48V Input)
95
90
85
EFFICIENCY %
80
FES200ZE-A
75
EFF. (36V)
70
65
60
10
20
30
40
50
60
70
80
90
100
LOAD %
EFF. (48V)
EFF. (75V)
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
REV. NOV 05, 2003
Page 1 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
Lucent-Compatible Trim
Trim
Enable
Trim and Enable
SUFFIX
N
T
1
2
3
APPLICABLE SERIES
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
IAS, LES
IAD, IAS, LES, SMS
IAS, LES
REMARKS
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Pin Length and Heat Sink Options
0.110" (2.8mm) Pin Length
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heat Sink
0.24" (6.1mm) Vertical Heat Sink
0.45" (11.4mm) Horizontal Heat Sink
0.45" (11.4mm) Vertical Heat Sink
0.95" (24.1mm) Horizontal Heat Sink
0.95" (24.1mm) Vertical Heat Sink
8
9
1H
1V
2H
2V
3H
3V
All Leaded Models
All Leaded Models
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Standard Pin Length is 0.180" (4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heat sink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. NOV 05, 2003
Page 3 of 3