EEWORLDEEWORLDEEWORLD

Part Number

Search

FDED124MK06-16P

Description
Circular Connector, 6 Contact(s), Nickel Aluminum Bronze, Plug,
CategoryThe connector    The connector   
File Size301KB,10 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

FDED124MK06-16P Overview

Circular Connector, 6 Contact(s), Nickel Aluminum Bronze, Plug,

FDED124MK06-16P Parametric

Parameter NameAttribute value
MakerEsterline Technologies Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED, PRESSURE: MATED 100 BARS
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGOLD OVER NICKEL
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsFLUID RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsWATERPROOF
Shell materialNICKEL ALUMINUM BRONZE
Housing size24
Total number of contacts6
M Series
Applications
Submarine : Sonars, degaussing, bulkhead
Subsea defense : mines, TAS
Underwater instrumentation : Cameras,
hydrophones, diving
Water pollution control : Pumps, valves
Offshore and oceanography : ROV,
subsea control, platform
Description
• Rugged screw coupling connectors in high
corrosion resistant shells which are made
in nickel aluminum bronze alloy. The design
provides a very high reliability with dry mate
sealing down to 2.000 meters immersion
(deeper depth with special backshells). The M
marine connector series is approved by
VERITAS and LLOYD’S Register of shipping.
Standard
Proprietary product line
Mechanical
Pressures
Test
pressure
Operating
pressure
Test
pressure
Operating
pressure
Insert in Teflon
®
Mated
Unmated
-
-
Insert in Kel’f
®
Mated
Unmated
200 bars
100 bars
Size
9M
-
-
100 bars
50 bars
200 bars
60 bars
200 bars
120 bars
Other Sizes
10, 14, 20, 24
100 bars
30 bars
100 bars
60 bars
Connectors double watertightness can withstand higher pressures than those above (test pressure : 300 bars mated connectors).
Note 1 :
For long unmated immersion use watertight caps.
Note 2 :
Please consult us about higher operating pressure than those above.
Shells :
Nickel aluminum bronze :
Cu A1 9 Ni 3 Fe 2, Scoop-Proof
Inserts :
Teflon
®
= PTFE
Polytetrafluorethylene.
or Kel’f
®
= PCTFE
Polymonochlorotrifluorethylene
®
Trade marks of Dupont de Nemours Inc.
Types of contacts :
Solder unremovable
except power contacts (sizes 2 and 6).
Plating of contacts:
Gold on nickel
Watertight washers :
Neoprene
Polarization :
With 5 keys
O-Rings :
Nitrile elastomer
Endurance :
500 cycles mating/unmating
Free-Fall :
Connecting plug or plug harness
< 1,5 m
Electrical features
Service rating at sea level test voltage :
• Voltage rating 1 - 1 500 Vrms 50 Hz
• Voltage rating 2 - 2 300 Vrms 50 Hz
• Voltage rating 3 - 15 000 Vrms 50 Hz
Operation voltage :
• Voltage rating 1 - 600 Vrms 50 Hz
• Voltage rating 2 - 1 000 Vrms 50 Hz
• Voltage rating 3 - 7 000 Vrms 50 Hz
Dielectric resistance :
5000 megohms at
20°C and 60 % relative humidity
Grounding resistance :
(receptacle and
plug assembled)
10 mΩ at 20 °C and 60 %
relative humidity
Environmental
Temperature range :
-20°C +70°C -68°F
+158°F
Marine environment :
30 years ageing
Vibrations :
From 0,1Hz to 1 Hz : amplitude = 25 mm
From 1Hz to 5 Hz : acceleration = 0,1 g
From 5Hz to 22Hz : amplitude = 1 mm
From 22Hz to 50Hz : acceleration = 2 g
Duration 1 hour on each axis
Shocks :
Static acceleration of 120 g on
each axis
Fluids resistance :
oil, alcohol, petrol, diesel
fuel, sea water
Various gases :
natural, butane, propane,
freon
Various acids
241
Weird 12864 proteus simulation
Without further ado, here is the entire program: I used Proteus to simulate the function and it made me depressed. I don't know what went wrong. #include#define DataPort P2 //Data port sbit E = P1^0; ...
bsliu2007 Embedded System
What are the components of the single chip microcomputer data acquisition system?
The data acquisition system generally consists of signal conditioning circuit, multi-channel switching circuit, sampling and holding circuit, analog-to-digital conversion, and basic single-chip microc...
Aguilera Microcontroller MCU
Just chat
I just took the low-level test and got 60 points, just enough to pass, haha. . ....
shelion Microcontroller MCU
Stray test line loss problem?
[color=#333333]Is there a problem with the line loss in stray test? Sometimes the measured value is a range, how to determine the line loss? [/color]...
gurou1 RF/Wirelessly
IO simulates serial port, the program runs a little unstable, I hope the expert can give me some advice
/***************************************************Program function: IO port simulates serial port. The clock is 30K and the baud rate is 9600.Sometimes it works stably, and sometimes it's all garble...
hider Microcontroller MCU
I would like to ask about the resistance of dynamic display.
I am not very good at this, so I can only draw some intuitive pictures to illustrate the problem. The following picture is my understanding. The current flows from +5V to P0 port. How big should the c...
zxpla MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2007  1395  2888  2559  312  41  29  59  52  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号