Part Number

Search

BK/ABC-1-1/2V

Description
Electric Fuse, Fast Blow, 1.5A, 250VAC, 125VDC, 100A (IR), Through Hole
CategoryCircuit protection    Circuit protection   
File Size114KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/ABC-1-1/2V Overview

Electric Fuse, Fast Blow, 1.5A, 250VAC, 125VDC, 100A (IR), Through Hole

BK/ABC-1-1/2V Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height32.82 mm
Body length or diameter6.76 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal2 J
Manufacturer's serial numberABC
Installation featuresTHROUGH HOLE
method of packingBOX
physical size6.76mm x 32.82mm
Rated breaking capacity100 A
Rated current1.5 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapePIN WIRE
1/4" x 1-1/4" Fuses
ABC Series, Fast Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
RoHS
2002/95/EC
Agency Information
• UL Listed Guide & File numbers (ABC 1/4 - 15A):
JDYX & E19180.
• UL Recognition Guide & File numbers (ABC 18 - 30A):
JDYX2 & E19180.
• CSA Certification Record No: 053787 C 000 &
Class No: 1422 01 & 1422 30.
Environmental Data
• Shock: 1/4A and 1/2A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 207,
(HI Shock)
• Vibration: 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions
(
mm
in
)
Drawing Not to Scale
SPECIFICATIONS
Product
Code
ABC-1/4
ABC-1/2
ABC-3/4
ABC-1
ABC-1-1/2
ABC-2
ABC-2-1/2
ABC-3
ABC-4
ABC-5
ABC-6
ABC-7
ABC-8
ABC-10
ABC-12
ABC-15
ABC-20
ABC-25
ABC-30
Voltage
Rating
AC
DC
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
125V
125V
125V
125V
AC Interrupting
Rating
250V
125V
35A
10000A
35A
10000A
35A
10000A
35A
10000A
100A
10000A
100A
10000A
100A
10000A
100A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
750A
10000A
750A
10000A
400A
1000A
-
1000A
-
1000A
DC Interrupting
Rating
125V
75V
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
400A
1000A
400A
1000A
Typical DC Cold
Resistance**
(ohms)
3.000
0.788
0.303
0.197
0.1175
0.0755
0.05875
0.0435
0.02975
0.0286
0.02315
0.0183
0.0146
0.01205
0.0068
0.005425
0.00366
0.00263
0.002225
Typical
Melting I
2
t†
AC
0.02
0.19
0.8
1.4
2.9
4.2
8.53
19.5
29.1
16.4
31.6
73.2
111.9
215.6
129.6
200.2
550.8
839.3
1,429
Typical
Voltage
Drop‡
3.25
0.51
0.42
0.35
0.35
0.25
0.26
0.25
0.25
0.23
0.24
0.20
0.17
0.15
0.11
0.12
0.13
0.12
0.14
Traditional Ferrule Fuses - Ferrule Type
** DC Cold Resistance (Measured at
≤10%
of rated current)
† Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage. Measured at 70% to 80% power factor on AC)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
OC-80
Press circuit
Dear brothers, I am an electronics novice. I just bought a press a few days ago and want to make it fully automatic. I know nothing about circuits. I need help from everyone to draw a simple diagram. ...
jgiunbku Analog electronics
2010 Network Communication Trends: 802.11n, WiMAX, Optical Access
The three development focuses of the network communication industry in 2010 are: 802.11n becoming the mainstream WLAN standard, WiMAX, and optical access (the proportion of EPON and GPON equipment shi...
征服 FPGA/CPLD
0
...
strongli2008 Embedded System
CPLD-Logical Relationship Help, Please Help
I recently made a motor driver board, using CPLD—EPM3032. Since I have never been exposed to this field before, I used the graphic input method to write the program on the maxplus platform. Now there ...
allenwang6392 FPGA/CPLD
Application of Four-way Two-Tube Forward Series-parallel Output Method in Maglev Train DC-DC Converter
As China's maglev trains develop from experiments to industrialization, the power supply voltage of its main circuit has moved from the previous DC: 750V to a higher voltage DC: 1500V. Although high-v...
simamy Power technology
Comparison of the internal structures of TI's three major series of DSPs
1 TMSC2000 SeriesThe C2000 series DSP is one of the three major series of TI's TMS320 DSP. It includes 16-bit C24xx and 32-bit C28xx fixed-point DSPs. It is based on the 320C2XLP core, a 4-stage pipel...
Jacktang DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2353  791  825  476  2535  48  16  17  10  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号