Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size2MB,6 Pages
ManufacturerEaton
Download Datasheet Parametric View All

LP210130 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

LP210130 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberLP2
Installation typeBOARD
Number of layers1
Rows1
Number of channels30
Rated current30 A
Rated voltage150 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
MAGNUM
®
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
A20510807WR
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
.375” or 3/8” (9.52 mm)
LP202110
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc plated philslot
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature
: 105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL/CSA; IEC Compliance;
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
CB20210507
A2000 & LP2000 Series
.375
(9.53)
.15
(3.8)
dia.
.65
(16.5)
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.38
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
C
Mount End
Barrier End
Base & Rail Mount
Connectors
.76 (19.3)
.40
(10.2)
.565 (14.35)
on LP2000
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB2000 Series
.19
(4.8)
dia.
Power Distribution Blocks
.375
(9.53)
.70
(17.8)
.32
(8.1)
Mount End
C
Barrier End
.60
(15.2)
WIRE MANAGEMENT PRODUCTS
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
6
Low-power keyless entry encryption transceiver technology for car immobilizers
This article analyzes the ever-changing methods of car theft and the corresponding development of car anti-theft technology, focusing on TI's latest car anti-theft solution - the encryption technology...
frozenviolet Automotive Electronics
Steps in Printed Circuit Board PCB Layout Design
Steps of PCB layout design Before the PCB layout design begins, a complete and detailed description of the circuit is required, mainly including the following aspects: 1) Schematic diagram, including ...
ESD技术咨询 PCB Design
It is strongly recommended to delete all political or sensitive topics
When I saw the post today that supported the Japanese, my first reaction was displeasure!I'm really sorry for complaining a little.Even if some people are very philanthropic and noble, I want to suppo...
chenzhufly Talking
I2C read and write operation timing
The i2c protocol mentions three possible transmission modes: 1. The master (transmitter) sends to the slave (receiver), and the direction of transmission does not change. S-->Slave Address-->R/W-->A--...
wangencheng Embedded System
Compile error problem help
I'm learning ZLG's LM3S1138 development board and using ZLG's routines. When compiling, I get this error message. What does it mean? Fatal Error[Pe005]: could not open source file "hw_adc.h" D:\ZLG\lm...
ZHANGXUEJIE Microcontroller MCU
Why can't I debug CCS7.0 suddenly?
An error has occurred. See error log for more details. com/ti/dvt/energytrace/views/DashboardI was using 7.0and the mouse unexpectedly stopped working. After forced shutdown and restart, the above err...
Aguilera Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2079  705  377  2078  2554  42  15  8  52  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号