EEWORLDEEWORLDEEWORLD

Part Number

Search

D3899924MG35HD

Description
MIL Series Connector, 79 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size707KB,13 Pages
ManufacturerHypertronics Corporation
Download Datasheet Parametric View All

D3899924MG35HD Overview

MIL Series Connector, 79 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

D3899924MG35HD Parametric

Parameter NameAttribute value
MakerHypertronics Corporation
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999, EMI SHIELDED, POLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGOLD OVER NICKEL
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsFLUID/IMMERSION RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing sizeG
Termination typeCRIMP
Total number of contacts79
HyperRel Series
HyperRel Series
Ruggedized Connectors Intermateable
with MIL-DTL-38999 Series III
Available with metal (HRM) and composite (HRC) shells
Ruggedized socket interconnects
High shock and vibration resistance
Metal and composite shell styles
Hypertac
®
style 39029 contacts
Intermateable with industry standard Mil 38999
Series III connectors
• Cable-to-cable and panel mount styles available
• Available with high temperature hyperboloid
contact technology
HRC (HyperRel Composite): Highlights
The HyperRel HRC is a high performance composite
connector intermateable with MIL-DTL-38999 Series III
connectors. The combination of the legendary Hypertac
contact with the superior design of the composite
shell/insert, along with the respective strain reliefs, favorably
influence intra-system life-cycle performance and costs.
Shells:
The total performance of the HRC connector is
matched by the individual components within the system.
For example, the use of composite materials increases
the durability of the connector housing and coupling
mechanism to 1500 cycles.
Specifications:
EMI shielding effectiveness
Meets and exceeds the requirements of MIL-DTL-38999,
paragraph 3.3.1
Fluid immersion
Meets and exceeds the requirements of MIL-DTL-38999,
paragraph 3.33
Temperature
The metal surface will not delaminate from the composite
material even after extreme temperature excursions.
The HRC meets all requirements of MIL-DTL-38999,
paragraph 3.8
Magnetic permeability
The magnetic permeability of the fully assembled HRC
connector is less than 2.0 µ, meeting all the requirements
of MIL-DTL-38999, paragraph 3.3.4
Materials
All the materials used in the shell and inserts in the HRC
are in accordance with MIL-DTL-38999, paragraph 3.3.
The contacts are in accordance with MIL-C-39029,
paragraph 3.3
Finish
Shells: Meet the requirements of MIL-DTL-38999
Contacts: Meets the requirements of MIL-C-39029
Insulation resistance
Meets all the requirements of MIL-DTL-38999,
paragraph 3.13
Dielectric withstanding voltage
Meets all the requirements of MIL-DTL-38999,
paragraph 3.14
Contacts:
Up to 80% less mating force
50% reduction in resistance
300% increase in mating cycles
Vibration/shock proven at 2 nano seconds
Five times more contact elements than the
MIL-C-39029 (e.g. Size number 22)
• Hypertac contact life expectancy (fretting) is
100 times longer than the MIL-C-39029 contact
The HRC eliminates the largest contributing factor in
advanced systems malfunction: corrosion – the main cause
of mechanical, electrical, and electromagnetic connector
degradation. Electromotive force differentials between many
dissimilar metals found in connectors and accessories
produce galvanic action. The HRC eliminates these dissimilar
metals resulting in an interconnect system that withstands
over 2000 hours of salt spray.
Dimensions are in inches [mm]
www.hypertronics.com
2 / 37
What is the current status of driver development?
Two years ago, I wrote a network card driver. At that time, I used WIN2000, 2000DDK, VC++6.0 and DriverStudio, and XP and XPDDK. Now I want to touch on this aspect again. I wonder what development pla...
zx8227112 Embedded System
The list of outstanding netizens from July to August is announced
[size=5][color=red]The results of the outstanding netizens in the Electronic Engineering World in July and August are announced: [/color][/size] [size=5][/size] [size=5] single Lianggua[/size] [size=5...
亲善大使 Suggestions & Announcements
Sony develops 2mm camera sensor to make drones smaller
[p=30, null, center][color=rgb(51, 51, 51)][size=16px][/size][/color][/p][p=30, null, left][color=rgb(51, 51, 51)][size=16px]Wearable devices equipped with cameras will become smaller and smaller in t...
fish001 RF/Wirelessly
I have been making small cars for a month. Experts, please see what level I am at.
[media=x,500,375]http://v.youku.com/v_show/id_XNDYzNTU1NDU2.html[/media]...
石玉 MCU
DSP code optimization instructions in CCS
[size=4][color=#000000][backcolor=white]The purpose of restrict is to restrict a pointer's access to a block of memory. To put it more concretely, if a memory area is accessed through a restricted poi...
灞波儿奔 Microcontroller MCU
Ask: Three problems in programming ADC in 2812
Question 1: The header file #include DSP28_Device.h of the InitSysCtrl.c file called at runtime cannot be opened.2: In the delay (20us delay), the calculation cycle count = (((20us*1000L)/cpu_clockspe...
IceA Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 381  2217  2575  1435  1228  8  45  52  29  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号