BK1/ABC-1-1/2-RV

Description
Electric Fuse, Fast Blow, 1.5A, 250VAC, 125VDC, 100A (IR), Through Hole, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size520KB,6 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK1/ABC-1-1/2-RV Overview

Electric Fuse, Fast Blow, 1.5A, 250VAC, 125VDC, 100A (IR), Through Hole, ROHS COMPLIANT

BK1/ABC-1-1/2-RV Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height32.82 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal1 J
Installation featuresTHROUGH HOLE
method of packingBOX
physical size6.35mm x 32.82mm
Rated breaking capacity100 A
Rated current1.5 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapePIN WIRE
1
4
˝ x 1
1
4
˝ Fast-Acting Ceramic Tube Fuses
ABC Series
Description
• Fast-acting
• Optional axial leads available
1
4
˝ x 1
1
4
˝ (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Agency Information
• UL Listed: Guide JDYX & File E19180.
• UL Recognition: Guide JDYX2 & File E19180.
• CSA Certification: Class 1422-01 & 1422-03, File
53787.
Environmental Data
• Shock:
1
4
-30A – MIL-STD-202,
Method 213, Test Condition J
• Vibration:
1
4
-30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions - mm (in)
Drawing Not to Scale
38.10
(1.500)
(REF)
32.82±0.79
(1.292±0.031)
38.10
(1.500)
(REF)
6.76
(0.266)
DIA. OF LEADS
0-15 Amp: 0.81 (REF)
(0.032)
18-30 Amp: 1.02 (REF)
(0.040)
31.75±0.79
(1.250±0.031)
6.48
(0.255)
6.35±0.1
(0.250±0.0)
Specifications
Part
Number
ABC-
1
/
4
-R
ABC-
1
/
2
-R
ABC-
3
/
4
-R
ABC-1-R
ABC-1-
1
/
2
-R
ABC-2-R
ABC-2-
1
/
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Voltage
Ratings
Vac
Vdc
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
250
125
250
125
250
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
Vdc Interrupting
Ratings (amps)
125
75
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Typical DC Cold
Ω
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc I
2
t AC†
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (mV)‡
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL
UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
‡‡
X
X
‡‡
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The interrupting ratings for 25A and 30A were
measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I
2
t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
0909
BU-SB09836
Page 1 of 2
Data Sheet 2000
Use LM555 to make a high power switching power supply.
Today I saw a customer's prototype using two LM555s to make a switching power supply. The power reached 3-4KW. Does anyone have such a circuit? Such a solution is worth learning! The IR2153 I used bef...
weihuahuangy Power technology
How long will it take for the 430 to be damaged if it is powered by 5V?
When I was soldering the board today, I found that the 3.3V power chip I was using was broken and the output was 5V. After I found out, I immediately turned off the power for about 7-8 seconds. I woul...
67067710 Microcontroller MCU
Read and write serial flash using nios - M25P16
Using the spi-controller in sopc, write a data to the specified address of the flash through the following program, and then read the data from this address. The program is as follows: #include "syste...
burton FPGA/CPLD
Ultra-low power motion detection package
Ultra-low power motion detection package...
taburiss001 Microcontroller MCU
National Day distribution!
I want to give some points, but my level is too low, I can only give 100 points -- Moderator, please don't put my post in the expansion section [img]http://forum.eeworld.net/PointForum/ui/scripts/eewo...
Anna2007 Embedded System
Pull-up Resistors Summary
Pull-up resistor: 1. When the TTL circuit drives the COMS circuit, if the high level output by the TTL circuit is lower than the lowest high level of the COMS circuit (generally 3.5V), then it is nece...
liuyong1989 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 855  2076  838  698  20  18  42  17  15  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号