EEWORLDEEWORLDEEWORLD

Part Number

Search

DN000UB69V100

Description
Electric Fuse, 100A, 690VAC, 200000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size319KB,5 Pages
ManufacturerMersen
Websitehttps://www.mersen.com/

With over 135 years of experience, more than 50 industrial sites and 18 R&D centers in 35 countries, Mersen Electrical Power is a global expert in power and advanced materials for high-tech industries. They offer a broad portfolio of electrical protection and control products and provide solutions for power management applications. The Mersen team works with customers around the world to design and deliver custom solutions and essential products for the commercial, industrial, renewable energy, power electronics and electric vehicle markets. Mersen's mission is to make its customers' applications safer and more reliable.

Download Datasheet Parametric View All

DN000UB69V100 Overview

Electric Fuse, 100A, 690VAC, 200000A (IR), Inline/holder,

DN000UB69V100 Parametric

Parameter NameAttribute value
MakerMersen
Reach Compliance Codecompliant
ECCN codeEAR99
body width20 mm
body height38.5 mm
Body length or diameter48 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal690 J
Installation featuresINLINE/HOLDER
method of packingBULK
physical size48mm x 20mm x 38.5mm
Rated breaking capacity200000 A
Rated current100 A
Rated voltage (AC)690 V
GuidelineDIN 43653; UL
surface mountNO
Terminal shapeTAB/BLADE

DN000UB69V100 Preview

Download Datasheet
Semiconductor fuses
fuses
Semiconductor (AC)
Protistor
®
Square-body Fuses
PSC gR/aR sizes 000/00
gR/aR - 500 to 690 VAC DIN 000
GERMAN STANDARD
gRB - URB from 20 to 400 A
Size: 000
- EXTREMELY HIGH BREAKING CAPACITY FUSES: PROTECTION OF
POWER SEMICONDUCTORS ACCORDING TO IEC 60269-1 and 4
- 690V VOLTAGE RATING (RATING 20 TO 400 A)
- gR CLASS (gRB RATINGS 20 TO 125 A) ACCORDING TO VDE 636-23
- CLEARING ALL OVERLOADS
- IMPROVING SAFETY AND PROTECTION
- ENABLING SELECTIVE COORDINATION WITH ALL FUSES
- aR CLASS (URB RATINGS 80 TO 400 A) ACCORDING TO VDE 636-23
AND IEC 60269.4
- ALL MODELS COMPLYING WITH DIN 43653-00C ARE
WITH OR WITHOUT BLOWN FUSE INDICATION
WITH TRIP INDICATOR
- MODEL COMPLYING WITH DIN 43620 (00C) STANDARD WITH
BLOWN FUSE INDICATION - WITH TRIP INDICATOR
Main Characteristics
Voltage
rating
UN( VAC)
Class
Current
rating
IN (A)
Pre-arcing Total clearing
I
2
t @ 1 ms I
2
t @ 660V
I
2
tt (A
2
s)
I
2
tp (A
2
s)
Watts loss
0.8 IN
IN
Tested
Breaking Capacity
Estimated
Breaking Capacity
690
gRB
690
URB
500
URB
16
20
25
32
40
50
63
80
100
125
80
100
125
160
200
250
315
350
400
8,2
12
20
39
70
102
210
475
970
1900
390
690
1300
2700
5250
9900
15500
22400
33200
60
80
150
270
460
730
1500
2900
6000
11800
2500
4200
8900
16000
31500
52000
82000
110000*
160000*
-
3.8
5.0
5.5
6.6
7.7
8.8
9.9
11
11.6
11.6
12.7
14.3
17.0
19.8
24.8
31.9
31.9
36.3
5,6
7
9
10
12
14
16
18
20
21
21
23
26
31
36
45
58
58
66
200 k A
@ 690 V
300 k A
@ 690 V
200 k A
@ 690 V
300 k A
@ 690 V
120 k A
@ 500 V
* @ Un
Minimum operating voltage for blown fuse indicator: 20 V
Minimum operating voltage for trip-indicator: 20 V
SCAC
50
12/04
Touch screens are growing rapidly and their appeal is irresistible
The rapid growth of touch screens is spurring fierce competition, driving technology development, and sparking interest from OEMs. iSuppli has predicted that global shipments of major touch screen tec...
songrisi MCU
Hello, Xiangban
I see that STM32 has VFQFPN36 package, but I have never seen what VFQFPN36 package looks like. Can you give me a protel99 pcb package diagram? ? ? Thank you...
victor9911 stm32/stm8
TOP2048 programmer (new product)
TOP2048 programmer (new product) , USB interface, supports Win98/Me/2000/xp, features: small size, no external power supply, reliable connection, support 2.5V~6.5V devices, support 64M large-capacity ...
rain MCU
I was planning to make an altimeter, but it seems I won't be able to show it off in time.
I started riding bikes with everyone a while ago. After going out a few times, I suddenly wanted to make an altimeter that can use a pressure sensor, and add a temperature and humidity sensor. There i...
shub1986 Microcontroller MCU
No advertising, learn about digital oscilloscopes that can test high-speed communication signals
As electronic devices increasingly incorporate RF and digital components, test equipment is beginning to incorporate a more advanced array of measurement tools for high-speed communications signal tes...
qwqwqw2088 Test/Measurement
Funny things that happened during the physical examination
1. When doing a chest X-ray, as soon as one of my colleagues got on the X-ray machine, the doctor called several other doctors: "Come on, come on, I've been doing this for 20 years, and today I finall...
sang000 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community