EEWORLDEEWORLDEEWORLD

Part Number

Search

8575K14-16

Description
Toggle Switch, 4PDT, Momentary, 18A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded
CategoryMechanical and electronic products    switch   
File Size154KB,5 Pages
ManufacturerEaton
Download Datasheet Parametric View All

8575K14-16 Overview

Toggle Switch, 4PDT, Momentary, 18A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded

8575K14-16 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeLOCKING LEVER
body width33.5 mm
body height40.6 mm
Body length or diameter41.6 mm
Contact (AC) maximum rated R load11A@115VAC
Maximum contact current (AC)11 A
Maximum contact current (DC)18 A
Contact (DC) maximum rated R load18A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life20000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature71 °C
Minimum operating temperature-65 °C
sealENVIRONMENTALLY SEALED
surface mountNO
Switch actionMOMENTARY
switch function4PDT
Switch typeTOGGLE SWITCH
Termination typeSCREW
MILITARY—ENVIRONMENTALLY SEALED SWITCHES
Series—8573, 8574, 8575
MIL-S-3950 IWTS Lever Locks
FEATURES
SPECIFICATIONS
• Environmentally sealed
• Environmentally sealed per MIL-S-3950
• 1, 2, and 4 pole circuitry
• MS approved and QPL’d per MIL-S-3950
• 2 & 3 position with maintained and
• Thermoset molding materials meet flame
momentary action
retardant requirements
• Integrated wire termination system
• Bushing: 15/32" - 32 thread
(IWTS) for ease of wiring
• Temperature Range: -85°F to +160°F
• Terminal numbers molded into silicone
(-65°C to +71°C)
base seal
• Accepts MIL-C-39029/1-101 pin
• Life: 20,000 operations at rated load
40,000 operations mechanical life
CURRENT RATINGS
No. of Catalog
Type of
Poles Number Operation
28VDC
Lamp Resistive Inductive
Load
Load
Load
5
20
15
4
15
10
7
20
15
5
18
10
5
20
12
4
18
10
115VAC
60 or 400Hz
Lamp Resistive Inductive
Load
Load
Load
3
15
10
2
15
7
4
15
15
2
11
8
4
15
15
2
11
8
1
2
4
8573
8574
8575
Maintained
Momentary
Maintained
Momentary
Maintained
Momentary
Minimum Rating: “Intermediate Current” per MIL-S-3950
LEVER LOCK SELECTION TABLE – T er minals Accept W
Ter minals Accept W
ir e Contact Within Dimensional Limits of M39029/1-102 for -16 wire size
ir e Contact Within Dimensional Limits of M39029/1-101 for -20 wire size
8573
CIRCUIT WITH LEVER IN...
Up
Position
Center
Position
Down
Position (Keyway)
Lever
x
Lock
Bushing
Style
8574
TWO POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
8574K1-16
K27-16
K5-16
K2-16
K28-16
8574K3-16
K29-16
K30-16
K31-16
K32-16
8574K33-16
K4-16
K34-16
K10-16
K35-16
8574K9-16
K6-16
K36-16
K7-16
K16-16
8574K37-16
K38-16
K11-16
K22-16
K20-16
8574K12-16
K39-16
K14-16
K15-16
K21-16
8574K19-16
K18-16
K40-16
K41-16
K13-16
8575
FOUR POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
MS27783-21A
-21B
-21D
-21E
-21F
MS27783-21G
-21H
-21J
-21K
-21L
MS27783-21M
-21N
-21P
-22D
-22F
MS27783-22G
-23D
-23F
-23G
-24E
MS27783-24F
-24K
-24M
-25F
-26F
MS27783-27E
-27L
-27N
-28E
-29F
MS27783-30F
-31E
-31F
-31K
-31L
8575K1-16
K27-16
K5-16
K2-16
K28-16
8575K3-16
K29-16
K30-16
K31-16
K32-16
8575K33-16
K4-16
K34-16
K10-16
K35-16
8575K9-16
K6-16
K36-16
K7-16
K16-16
8575K37-16
K38-16
K11-16
K22-16
K20-16
8575K12-16
K39-16
K14-16
K15-16
K21-16
8575K19-16
K18-16
K40-16
K41-16
K13-16
ONE POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
*
*
*
ON§
OFF§
ON
A
ON
OFF§
ON
B
ON§
OFF
ON
D
ON
OFF§
ON
E
ON§
OFF
ON
F
ON
OFF
ON
G
ON§
OFF§
ON
H
ON
OFF
ON
J
ON§
OFF§
ON
K
ON
OFF§
ON
L
ON§
OFF
ON
M
ON
OFF
ON
N
ON
OFF§
ON
P
ON§
NONE
OFF
D
ON§
NONE
OFF
F
ON
NONE
OFF
G
ON§
NONE
ON
D
ON§
NONE
ON
F
ON
NONE
ON
G
ON
OFF§
NONE
E
ON§
OFF
NONE
F
ON§
OFF§
NONE
K
ON§
OFF
NONE
M
ON§
OFF
NONE
F
ON§
NONE
ON
F
ON
OFF§
ON
E
ON
OFF§
ON
L
ON
OFF
ON
N
NONE
OFF§
ON
E
ON§
NONE
OFF
F
OFF§
NONE
ON
F
ON
OFF§
ON
E
ON§
OFF
ON
F
ON§
OFF§
ON
K
ON
OFF§
ON
L
Momentary contact.
§
Indicates direction against which lever is locked.
*
*
*
*
*
*
*
*
*
*
*
*
*
MS27781-21A
8573K1-16
MS27782-21A
-21B
K27-16
-21B
-21D
K5-16
-21D
-21E
K2-16
-21E
-21F
K28-16
-21F
MS27781-21G
8573K3-16
MS27782-21G
-21H
K29-16
-21H
-21J
K30-16
-21J
-21K
K31-16
-21K
-21L
K32-16
-21L
MS27781-21M
8573K33-16
MS27782-21M
-21N
K4-16
-21N
-21P
K34-16
-21P
-22D
K10-16
-22D
-22F
K35-16
-22F
MS27781-22G
8573K9-16
MS27782-22G
-23D
K6-16
-23D
-23F
K36-16
-23F
-23G
K7-16
-23G
-24E
K16-16
-24E
MS27781-24F
8573K37-16
MS27782-24F
-24K
K38-16
-24K
-24M
K11-16
-24M
-25F
K22-16
-25F
-26F
K20-16
-26F
MS27781-27E
8573K12-16
MS27782-27E
-27L
K39-16
-27L
-27N
K14-16
-27N
-28E
K15-16
-28E
-29F
K21-16
-29F
MS27781-30F
8573K19-16
MS27782-30F
-31E
K18-16
-31E
-31F
K40-16
-31F
-31K
K41-16
-31K
31L
K13-16
-31L
See page 73 for circuit diagrams.
x
Reference bushing styles on Page 42.
I made the board myself, but the touch screen doesn't respond
I imitated the development board of S3C2410a, made a baseboard according to my needs (the core board inserted on it was not made), drew the PCB, and only used the power supply, serial port and LCD scr...
liyanfang39 Embedded System
Circuit Diagram 30-Analysis of Electrical Control Circuit Principles
[i=s]This post was last edited by tiankai001 on 2018-2-11 11:07[/i] [align=left][color=rgb(34, 34, 34)][font="]The electrical control circuit is mainly composed of buttons, relays, contactors, etc. It...
tiankai001 Integrated technical exchanges
Recommend a photoelectric speed sensor
Please help me choose a speed sensor that can output counting pulses and preferably has a working voltage of 5V. Thank you very much! ! It should be selected from photoelectric sensors, a general one ...
屋檐雨 Sensor
PHYTEC's imx8mplus development board review
We received the imx8mplus development board from PHYTEC for evaluation, and last time we had it up, everything was working fine. The official website comes with a paper document for rapid development,...
yijiu98 Toshiba Photorelays TLP3547 Review
STC MCU A/D conversion program problem
I use the AD that comes with stc12c5608AD to make an AD conversion program. The specific code is as follows: void ad_cov() { P1M0=P1M0||0x20; P1M1=P1M1||0x20; //Select P1.5 as open drain. (Mode select...
63745006 Embedded System
[RVB2601 Creative Application Development] 4. Use RTC to record time
[i=s]This post was last edited by hehung on 2022-3-6 19:28[/i]PrefaceRTC is a good choice for recording time. It does not require an external clock chip and can also achieve the purpose of obtaining a...
hehung XuanTie RISC-V Activity Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 962  437  2271  1467  222  20  9  46  30  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号