EEWORLDEEWORLDEEWORLD

Part Number

Search

MMTS-23-24-C-F03.25-D

Description
Interconnection Device
CategoryThe connector    The connector   
File Size96KB,3 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

MMTS-23-24-C-F03.25-D Overview

Interconnection Device

MMTS-23-24-C-F03.25-D Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
REVISION B
DO NOT
SCALE FROM
THIS PRINT
FIG. 1
MMTD-06-20-X-X-XX.XX-S SHOWN
C1-A-DC
MMTXX-XX-XX-X-X-XX.XX-X-XXX
B
ROW OPTION
-D: DOUBLE
-S: SINGLE (SEE SHT 3, FIG. 4)
PTFE CABLE OPTION
-T: PTFE
(LEAVE BLANK FOR
STANDARD PVC INSULATION)
No OF POSITIONS
-02 THRU -25 (PER ROW)
WIRE GAUGE (AWG)
-20, -22, -24, -26, -28, -30
PTFE: -24,-28,-30
COLOR CODE
-C (SEE TABLE 2)
(LEAVE BLANK FOR
STANDARD BLACK CABLE)
(NOT AVAILABLE WITH PTFE OPTION)
PLATING SPECIFICATION
-F: FLASH SELECTIVE (USE T-1M74-XX-F)
-L: LIGHT SELECTIVE (USE T-1M74-XX-L)
-S: SELECTIVE (USE T-1M74-XX-S)
OPTION
[MUST BE USED ON -D END OPTION ONLY
& APPLIES TO END 2 HOUSING]
-TUS: TRANSFER LATCH UP, STRAIGHT
(SEE FIG.2, SHEET 2)
-TDS: TRANSFER LATCH DOWN, STRAIGHT
(SEE FIG.3, SHEET 2)
01 02
(NO OF POS X.100 [2.54])
+.070 [1.78] REF
C2-A-DC
.300 7.62 REF
'C'
"A"
IPM1-06-D
END OPTION
-S: SINGLE END
-D: DOUBLE END(MUST CHOOSE TUS OR TDS OPTIONS.)
ASSEMBLED LENGTH
SPECIFY IN INCHES [USE DWCX-XX-XX]
(SINGLE END: 03.00[76.2] INCH MINIMUM,
DOUBLE END: 03.25[82.6] INCH MINIMUM)
C3-A-DC
.690 17.53 REF
"A"
.020 0.51
REF
C4-B-GR
XX.XX
C
(SEE NOTE 10)
.035 0.89 REF
'B'
.035 0.89 REF
DETAIL 'C'
SCALE 8 : 1
DWCX-XX-XX
.004 0.10 REF
(SEE NOTE 5)
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. NOTE DELETED
3. NOTE DELETED
4. MINIMUM PULLOUT FORCE: 0.5 lbs [2.22 N].
C
5. CONTACT MUST BE INSERTED UNTIL RETENTION FEATURE LOCKS
INTO PLACE.
C
6. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING
HI-POT TEST @ 1000 VOLTS DC.
7. TINNED COPPER WIRE CONTAINS LEAD.
8. PARTS ARE TO BE LAYER PACKAGED.
9. MMTX: SEE DWL-12-XX-X-XX.XX-XX-XX FOR CRIMP DIMENSIONS.
C6-B-MM
MMTXT: SEE DWLT-12-XX-X-XX.XX-XX-XX.
10. FOR LENGTHS LESS THAN 12 IN[304.8], TOLERANCE SHALL BE ±.125[3.18].
FOR OTHER LENGTHS, TOLERANCES SHALL BE ± 2%.
DETAIL 'B'
SCALE 8 : 1
SECTION "A"-"A"
SCALE 4 : 1
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
MATERIAL:
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Ma il: info @SAMTEC.c o m
c o d e: 55322
DESCRIPTION:
DO NOT SCALE DRAWING
SHEET SCALE: 2:1
HOUSING: NYLON 6/6, COLOR: WHITE
CONTACT: PHOS BRONZE
CABLE: INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
c:\enterprisevault\DWG\MISC\MKTG\MMTXX-XX-XX-X-X-XX.XX-X-XXX-MKT.SLDDRW
.100[2.54] TERMINAL DISCRETE CABLE ASSEMBLY
DWG. NO.
MMTXX-XX-XX-X-X-XX.XX-X-XXX
BY:
D. SCHMELZ 12/04/2008
SHEET
1
OF
3
Getting Started with the FRDM-KW41Z - GPIO Input
[i=s]This post was last edited by dql2016 on 2017-5-25 16:38[/i] The KW41Z library is really confusing. I am not familiar with it. It took me a long time to finally get it OK. First, define two struct...
dql2016 NXP MCU
Permanent magnet synchronous motor starting problem
I'm using 28335 to control a permanent magnet synchronous motor. When I run build 1 and build 2, the motor starts vibrating. I'd like to ask the experts what the reason is. Is it because the initial p...
你及我上半大去 Microcontroller MCU
Double T notch filter s-domain calculation analysis (pure manual calculation, engineering version!)
[font=微软雅黑][size=3] New progress in ufun simulation: Ufun author Zhang Daxia's handwritten parchment book, purely handmade, rough art and noble virtue:victory:[/size][/font] [font=微软雅黑][size=3]{:1_102...
nmg stm32/stm8
A must-read for those who draw boards: How to design circuit boards that meet electromagnetic compatibility requirements
The importance of electromagnetic compatibility needs no further explanation. This book is a translation of the classic "Printed Circuit Board Design Techniques for EMC Compliance". It is in tradition...
shoreway PCB Design
Discussion on the use of display instruments
For example, if a display meter receives a 4-20MA current signal from a transmitter, can several meters be connected in series for display? Personally, I think that if the instrument is current driven...
eeleader Industrial Control Electronics
MM32F103 BUG reminder to avoid pitfalls
I applied for MM's F103 development board and made a J1939 module. I used the CAN pins of PA11/PA12. The relevant pin configuration in the official SDK is shown in the figurePlease shield the breakpoi...
54chenjq Motor Drive Control(Motor Control)

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 376  587  250  435  300  8  12  6  9  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号