EEWORLDEEWORLDEEWORLD

Part Number

Search

D3899920MG16JB

Description
MIL Series Connector, 16 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size707KB,13 Pages
ManufacturerHypertronics Corporation
Download Datasheet Parametric View All

D3899920MG16JB Overview

MIL Series Connector, 16 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

D3899920MG16JB Parametric

Parameter NameAttribute value
MakerHypertronics Corporation
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999, EMI SHIELDED, POLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGOLD OVER NICKEL
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsFLUID/IMMERSION RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing sizeG
Termination typeCRIMP
Total number of contacts16
HyperRel Series
HyperRel Series
Ruggedized Connectors Intermateable
with MIL-DTL-38999 Series III
Available with metal (HRM) and composite (HRC) shells
Ruggedized socket interconnects
High shock and vibration resistance
Metal and composite shell styles
Hypertac
®
style 39029 contacts
Intermateable with industry standard Mil 38999
Series III connectors
• Cable-to-cable and panel mount styles available
• Available with high temperature hyperboloid
contact technology
HRC (HyperRel Composite): Highlights
The HyperRel HRC is a high performance composite
connector intermateable with MIL-DTL-38999 Series III
connectors. The combination of the legendary Hypertac
contact with the superior design of the composite
shell/insert, along with the respective strain reliefs, favorably
influence intra-system life-cycle performance and costs.
Shells:
The total performance of the HRC connector is
matched by the individual components within the system.
For example, the use of composite materials increases
the durability of the connector housing and coupling
mechanism to 1500 cycles.
Specifications:
EMI shielding effectiveness
Meets and exceeds the requirements of MIL-DTL-38999,
paragraph 3.3.1
Fluid immersion
Meets and exceeds the requirements of MIL-DTL-38999,
paragraph 3.33
Temperature
The metal surface will not delaminate from the composite
material even after extreme temperature excursions.
The HRC meets all requirements of MIL-DTL-38999,
paragraph 3.8
Magnetic permeability
The magnetic permeability of the fully assembled HRC
connector is less than 2.0 µ, meeting all the requirements
of MIL-DTL-38999, paragraph 3.3.4
Materials
All the materials used in the shell and inserts in the HRC
are in accordance with MIL-DTL-38999, paragraph 3.3.
The contacts are in accordance with MIL-C-39029,
paragraph 3.3
Finish
Shells: Meet the requirements of MIL-DTL-38999
Contacts: Meets the requirements of MIL-C-39029
Insulation resistance
Meets all the requirements of MIL-DTL-38999,
paragraph 3.13
Dielectric withstanding voltage
Meets all the requirements of MIL-DTL-38999,
paragraph 3.14
Contacts:
Up to 80% less mating force
50% reduction in resistance
300% increase in mating cycles
Vibration/shock proven at 2 nano seconds
Five times more contact elements than the
MIL-C-39029 (e.g. Size number 22)
• Hypertac contact life expectancy (fretting) is
100 times longer than the MIL-C-39029 contact
The HRC eliminates the largest contributing factor in
advanced systems malfunction: corrosion – the main cause
of mechanical, electrical, and electromagnetic connector
degradation. Electromotive force differentials between many
dissimilar metals found in connectors and accessories
produce galvanic action. The HRC eliminates these dissimilar
metals resulting in an interconnect system that withstands
over 2000 hours of salt spray.
Dimensions are in inches [mm]
www.hypertronics.com
2 / 37
The confusion of a developer over thirty years old
I am over thirty years old and have been engaged in software development for ten years. During this period, I have experienced changes in various languages and development models. After going through ...
小威 Embedded System
How to implement analog serial communication with TI MSP430
1. Background: In many cases, due to limited hardware resources, but serial communication is needed, you can consider using an analog serial port; 2. Prerequisites: To achieve a specific bps serial po...
Aguilera Microcontroller MCU
eboot won't start? ?
OEMVerifyMemory: dwStartAddr=0x0, dwLength=0x0 Why is the length of dwLength 0? It is different from the actual downloaded value. Does anyone know why?...
fengleigood Embedded System
Graphical explanation of the use and maintenance of soldering iron tips
Central topics: How to use and maintain the soldering iron tip Solution: Cleaning before weldingProtect and reduce oxidation rate during weldingAdd a new layer of tin for protection after welding Main...
cscl Test/Measurement
ffmpeg port on at91sam9261ek
[size=4]Finally I have some free time, and suddenly I remembered a long-lost wish, which is to port ffmpeg and mame to arm or dsp platform by myself. [/size] [size=4] So I found the website of ffmpeg ...
fish001 Microcontroller MCU
What is the relationship between the data written by the microcontroller to the RXFIFO of cc2420 and the packets sent out by cc2420? Please help!
I would like to know the relationship between the data written by the microcontroller to the RXFIFO of the cc2420 through the SPI bus and the packets sent out by the cc2420. Thank you!...
yqw001 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1153  1857  1139  1661  2155  24  38  23  34  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号