EEWORLDEEWORLDEEWORLD

Part Number

Search

200E-2C-15.5L

Description
Electric Fuse, 200A, 15500VAC, 60000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size383KB,5 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

200E-2C-15.5L Overview

Electric Fuse, 200A, 15500VAC, 60000A (IR), Inline/holder

200E-2C-15.5L Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
body height479.4 mm
Body length or diameter162 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial number200E-2C-15.5
Installation featuresINLINE/HOLDER
physical size162mm x 479.4mm
Rated breaking capacity60000 A
Rated current200 A
Rated voltage (AC)15500 V
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
E Rated Medium Voltage Fuses
Current Limiting
“E” Rated fuses have time current characteristics designed
to provide current limiting protection for power transformers,
potential transformers, power centers, feeder centers, and
unit sub stations. When properly applied, they can protect
against high and low value fault currents.
NEMA Standards for “E” rated medium voltage fuses require
that fuses rated 100E or less open within 300 seconds (5
minutes) when subjected to an RMS value of 200-240% of
the fuse’s continuous current rating; and fuses with an “E”
rating larger than 100E must open within 600 seconds (10
minutes) when subjected to an rms current of 220-240% of
the fuse’s continuous current rating. These values establish
one point on the time-current curve.
Application Note:
Since these fuses are used for the protection of general
purpose circuits which may contain transformers, motors,
and other equipment producing inrush and/or overload cur-
rents, fuses should generally be rated at 140% of the normal
full load current, and circuits should be analyzed to ensure
that system load currents will not exceed the current rating
of the fuse.
CHARACTERISTICS
Voltage Rating:
2,400 volts – 38,000 volts
Current Range:
10E – 600E
OPTIONS
I
I
Hermetically Sealed for use in hazardous locations
(add “S” suffix to part number)
Clip-lock (CL) and bolt-in styles available.
3"DIA
6.38"
9.75"
Dim.A
(Clip
Center)
Dim.B
FIGURE 14
FIGURE 15
FIGURE 16
E
RATED
Catalog
Number
10E-1C-2.75
15E-1C-2.75
20E-1C-2.75
25E-1C-2.75
30E-1C-2.75
40E-1C-2.75
50E-1C-2.75
65E-1C-2.75
80E-1C-2.75
100E-1C-2.75
125E-1C-2.75
150E-1C-2.75
200E-1C-2.75
125E-2C-2.75
150E-2C-2.75
175E-2C-2.75
200E-2C-2.75
225E-2C-2.75
250E-2C-2.75
300E-2C-2.75
350E-2C-2.75
400E-2C-2.75
450E-2C-2.75
Old
Catalog
Number
LCX 10E
LCX 30E
LCX 40E
LCX 50E
LCX 65E
LCX 80E
LCX 100E
LCX 125E
LCX 150E
LCX 175E
LCX 200E
LCX 250E
LCX 300E
LCX 400E
Size
10E
15E
20E
25E
30E
40E
50E
65E
80E
100E
125E
150E
200E
125E
150E
175E
200E
225E
250E
300E
350E
400E
450E
Dim. A
(inches)
Dim. B
(inches)
Max
Interrupting
Rating
RMS (Asym)
7"
10.875"
80,000
7"
10.875"
80,000
Figure
Number
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
2.75 Max. KV
67
I used pwm and wrote the program according to the routine, but there is a problem
TBCCR0 = 4096-1; // PWM Period TBCCTL4 = OUTMOD_7; // CCR4 reset/set TBCCR4 = 512; // CCR4 PWM duty cycle TBCCTL5 = OUTMOD_7; // CCR5 reset/set TBCCR5 = 32; // CCR5 PWM duty cycle TBCTL = TBSSEL_2 + M...
shzps Microcontroller MCU
K60 PDB KEIL Programming
1. Experts, I would like to ask, what is the so-called delay of the programmable delay module PDB? It should be different for ADC and DAC modules, right? Then for different operation modules, which st...
Monkey嘭嘭 NXP MCU
How many IRQs should be added to the registry?
#define AT91C_ID_IRQ1 ((unsigned int) 30) // Advanced Interrupt Controller (IRQ1) I use IRQ1, which is defined as up. So how much IRQ should I add to the registry? 1E or 30? I tried 1E and it didn't w...
洗了八吨水 Embedded System
Selection criteria for semiconductor diodes (cqcwc)
Selection criteria of diodes (cqcwc) Selection criteria of diodes in circuit design 1. Selection based on circuit function: Germanium detection diodes should be used for high-frequency detection circu...
fighting Analog electronics
Has anyone used AMIS-30543 to drive a stepper motor?
Is the PWM frequency of the AMIS-30543 driving the stepper motor fixed? How to detect the current? What is the function of the back EMF output pin?...
沈婷婷 Motor Drive Control(Motor Control)
Problem with Uart_GetIntNum()!
A simple program y=Uart_GetIntNum(); Uart_Printf("%d",y); For example, if I enter 233 in the hyperterminal, the return value is 2. What's going on?...
FSDAFSDAFTERT Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1662  1952  2278  891  1001  34  40  46  18  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号