EEWORLDEEWORLDEEWORLD

Part Number

Search

CECC16101-007-01-31-07-04P

Description
Power/Signal Relay,
CategoryMechanical and electronic products    relay   
File Size417KB,5 Pages
ManufacturerHi-G Relays
Download Datasheet Parametric View All

CECC16101-007-01-31-07-04P Overview

Power/Signal Relay,

CECC16101-007-01-31-07-04P Parametric

Parameter NameAttribute value
MakerHi-G Relays
Reach Compliance Codeunknown
ECCN codeEAR99
Manufacturer's serial number2K-6600
Relay typePOWER/SIGNAL RELAY
HALF SIZE CRYSTAL CAN RELAY
Series
2 AMPERE DPDT
2K-6600
Product Description
A complete series of half crystal can hermetically sealed relays manufactured and qualified to the referenced CECC specifications. The
leading relay design in military and commercial application is represented in Hi-G 2K-6600 series relay. The product advanced design
provides superior performance in the environmental and operational requirements of today’s sophisticated equipment. Volume
production coupled with continuing qualification programs, ensure product consistency and the highest degree of reliability.
The following construction features ensure the highest reliability in extreme environments:
-
All welded relay construction
-
Cleaning and sealing techniques ensures maximum internal cleanliness
-
Low level to 2 amperes switching
-
2 form C, DPDT contacts, special metal alloy with gold plating
-
Frame, armature designs and force / mass ratio provides exceptional immunity to shock and vibration.
Series Type
-
2K-6600
2 form C, DPDT
Code
01
02
Contact Category
Light Duty Contact
0,01 mA, 5 Vdc max.
0,01 mA, 0,01 Vdc max.
Types
007, 014, 021
021
CECC 16101 – 007
16101 – 014
16101 – 021
(SEE NOTE *)
Environmental and Physical Specifications
Temperature (Ambient)
Shock
Vibration (sinusoidal)
Bump
Sealing
Weight
Finish
- 65°C to + 125°C
50 g, 11 ms., half sine wave
20 g, 10 to 2000 Hz, 1,5 amplitude peak
40 g, 6 ms.
All welded, Hermetic
0,46 oz. (13,0 grams) max.
Bright tin lead plated terminals and case
* NOTE:
- 007
- 014
- 021
ITALIAN FACTORY SPECIFICATION
GERMAN / FRENCH FACTORY SPECIFICATION
UK FACTORY SPECIFICATION
A part from the range and a few environmental tests, all specs. are identical.
Nuova Hi-G is the only company qualified to each / all country specs.
Electrical Characteristics
(over the Temperature range. Unless otherwise noted)
Coil Data
Contact Rating
(Note: All ratings with grounded
case)
See Typical Characteristics chart
Type Load
Contact Load
Low Level
10 mA / 30 mV
Resistive
2 A / 28 Vdc
Overload
4 A / 28 Vdc
Inductive
0,75 A / 28 Vdc (200 mH)
0,05
max. initial, 0,2
max. after life
Cycles min.
1.000.000
100.000
100
100.000
Contact Resistance
Operate Time
Release Time
Contact Bounce
Dielectric Strength
Insulation Resistance
Intercontact Capacitance
Sensitivity
4,0 ms. max. at 25°C
4,0 ms. max. at 25°C
2,5 ms. max. at 25°C. Series: 007, 014
3,0 msec. max. at 25°C. Series: 021
500 Vrms min., 60 Hz, all points, at sea level
1.000 M min. all points at 500 Vdc
2,5 pF typical
250 mW at pick-up, 1,0 W max., at nominal rated coil voltage, at 25 °C
High Generation S.r.l.
Tel: + 39 06 96873136
Fax: + 39 06 94443060
37
REV. 0/2012
How to update and upgrade GPS navigation electronic maps
As we all know, navigation electronic maps are the core and foundation of GPS navigation. Navigation map updates and upgrades are the lifeline of navigation maps, and even the standard for the surviva...
KG5 Automotive Electronics
【GD32L233C-START Review】Five simple temperature and humidity displays
[i=s]This post was last edited by hl23889909 on 2022-4-17 09:03[/i]OverviewThe hardware required for this demo: GD32L233C-START evaluation board, OLED display, AHT25 temperature and humidity sensor:SP...
hl23889909 GD32 MCU
HIVE-BASE+FAT?
How to implement the FAT configuration registry to achieve automatic partitioning function, because my EBOOT does not have a partitioning function, but I want to implement HIVE-BASE+FAT? Environment: ...
zhang_shuai2005 Embedded System
Datetime issues in D600
Calling Datetime.now.tostring() returns [b]2009-03-16 17:33:11 [/b] on the simulator. Connecting D600 for debugging, datetime.now returns [b]2009-03-16 Monday 17:33:11 [/b] on S900. Why is there an ex...
tmhill Embedded System
ad The mouse pointer becomes invisible when it overlaps with the grid
The pointer becomes unclear as soon as it overlaps with the grid. I have tried many methods but cannot solve the problem. Does anyone know? Thank you....
PCB我不会 PCB Design
We are "industrial control people"???
Industrial control people always live in contradiction, wandering between heaven and hell! Industrial control people are a group of people who are involved in a wide range of fields. They can be seen ...
wdxyx Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 409  2741  959  1015  1020  9  56  20  21  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号