5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 Fax 401-823-8723 Email advintcorp@aol.com Internet http://www.advintcorp.com
.100" (2.54 mm) Pitch Board to Board Interconnections
NB/LNB - Single Row
Molded Female
DRS - Dual Row
Molded Female
NA - Single Row
Molded Male
DRA - Dual Row
Molded Male
KSS - Single Row
Peel-A-Way
®
Female
DKS - Dual Row
Peel-A-Way
®
Female
NEW PHOTO
Low Profile
Board to Board
KSA - Single Row
Peel-A-Way
®
Male
DKA - Dual Row
Peel-A-Way
®
Male
Features:
!
High reliability method of
interconnecting.
!
Reliable mechanical support.
!
Complete flexibility. If the board to
board spacing you need is not shown
on pages 54 - 55 , consult factory.
Terminals and Contacts:
Terminal: Brass - Copper Alloy 360,
ASTM-B-16
Contact: Beryllium Copper - Copper
Alloy 172, ASTM-B-194
Plating:
Terminal: Gold over Nickel or
Tin-Lead over Nickel
Contact: Gold over Nickel or
Tin-Lead over Nickel
Body Material:
Molded -
Glass filled thermoplastic
Polyester (P
.B.T.) U.L. Rated 94V-O,
-60
°
C to 140
°
C (-76
°
F to 284
°
F)
High Temp Molded
- High temp. glass
filled thermoplastic, U.L. Rated 94V-O,
-60
°
C to 260
°
C (-76
°
F to 500
°
F)
Peel-A-Way
®
- Polyimide Film - Temp.
range -269
°
C to 400
°
C(-452
°
F to 752
°
F)
Page 52
How To Order
Single and Dual RowFemale
NB
010
-01
T
G
Contact Plating
G - Gold
T - Tin-Lead
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Body Type
NB/LNB - Single Row Molded
HNB/HLNB - Single Row High Temp Molded
KSS - Single Row Peel-A-Way
®
DRS - Dual Row Molded
HDRS - Dual Row High Temp Molded
DKS - Dual Row Peel-A-Way
®
Number of Pins
NB/LNB - 3 - 32, KSS - 2 - 100
DRS - 20 - 70, DKS - 4 - 200
How To Order
Single and Dual Row Male
NA
Body Type
NA - Single Row Molded
HNA - Single Row High Temp Molded
KSA - Single Row Peel-A-Way
®
DRA - Dual Row Molded
HDRA - Dual Row High Temp Molded
DKA - Dual Row Peel-A-Way
®
010
-68
T
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Number of Pins
NA/HNA - 3 - 32, KSA - 2 - 100
DRA/HDRA - 20 - 70, DKA - 4 - 200
Peel-A-Way® covered by patent rights issued and or pending.
inch/(mm)
Quick turn delivery available on standard terminal types.
.
5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 •Fax 401-823-8723 •Email advintcorp@aol.com •Internet http://www.advintcorp.com
®
®
ADVANCED
Board to Board Interconnections
INTERCONNECTIONS
.100" (2.54 mm) Pitch Board to Board Interconnections
Male Terminal Information
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.070
(2.16)
.030
(.76)
.125
(3.18)
.125
(3.18)
.018 Dia.
(.46) Typ. 2
.018 Dia.
(.46) Typ. 2
Type -79
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
Type -80
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.085
(2.16)
.125
(3.18)
Type -81
Type -444
.018 Dia.
(.46)
.125
(3.18)
.052
(1.32)
.103
(2.62)
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46) Typ. 2
Type -68
.018 Dia.
(.46)
.125
(3.18)
.100
(2.54)
Type -43
.018 Dia.
(.46)
.125
(3.18)
Type -399
.018 Dia.
(.46)
.125
(3.18)
Type -185
.018 Dia.
(.46)
.125
(3.18)
.210
(5.33)
.335
(8.51)
.100
(2.54)
.100
(2.54)
.379
(9.63)
.100
(2.54)
.500
(12.70)
Board to Board
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Type -42
.018 Dia.
(.46)
.125
(3.18)
Type -398
.018 Dia.
(.46)
.125
(3.18)
Type -403
.018 Dia.
(.46)
.125
(3.18)
Type -71
.018 Dia.
(.46)
.125
(3.18)
.585
(14.86)
.100
(2.54)
.100
(2.54)
.679
(17.25)
.100
(2.54)
.750
(19.06)
.100
(2.54)
.835
(21.21)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Female Terminal Information
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -210
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -85
Type -299*
.050(1.27) Molded Insulator Thickness
.072 Dia.
(1.83)
Type -49*
.072 Dia.
(1.83)
.015
(.38)
.083
(2.11)
.155
(3.94)
.031
(.79)
.095
(2.41)
.155
(3.94)
.082
(2.08)
.095
(2.41)
.028 Dia.
(.71)
.034 Dia.
(.86)
.038 Dia.
(.97)
.025 Dia.
(.64)
Type -04*
.072 Dia.
(1.83)
Type -51*
.072 Dia.
(1.83)
Type -01
Molded Body Only
.072 Dia.
(1.83)
Peel-A-Way® Only
.072 Dia.
(1.83)
Type -33
.120
(3.05)
.130
(3.30)
.165
(4.19)
.165
(4.19)
.110
(2.79)
.028 Dia.
(.71)
.020 Dia.
(.51)
.110
(2.79)
.125
(3.18)
.020 Dia.
(.51)
.125
(3.18)
.020 Dia.
(.51)
inch/(mm)
* These terminal types are available in either molded or Peel-A-Way®.
Peel-A-Way® covered by patent rights issued and or pending.
I am using DSP: DM642, programming in C, platform CCS3.1, computer simulation. The program can run on TC, but when I run it on CCS, it prompts: Trouble running Target CPU: Memory Map Error: WRITE acce...
I work in a small company and now develop PDA data collection related programs. The company is small, the technology is weak, the work is complicated, and it is difficult to develop~, but I have to fa...
It's a long story. I need a hard drive recently. Since it's for NAS, I naturally choose a red disk. Red disk is specially designed for NAS. It has low power consumption and low noise. It can run 7*24....
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
With the rapid development of urban economy, elevators are increasingly used as a vertical transportation tool. However, elevator fault detection and maintenance, especially the role of elevator remot...[Details]
0 Introduction
With the development of society, people pay more and more attention to security work. Monitoring products have been used in various fields instead of being used only in importan...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
LED is the abbreviation of light emitting diode, which is an electric light source made of semiconductor technology. The core part of LED is a chip composed of P-type semiconductor and N-type semi...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Nippon Electric Works and Volvo Technology Japan have developed a wireless power supply system for electric vehicles (EVs). Using this system, the two companies have successfully conducted an exper...[Details]