EEWORLDEEWORLDEEWORLD

Part Number

Search

803-014-DD2NF12-3PX-72

Description
Interconnection Device,
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-014-DD2NF12-3PX-72 Overview

Interconnection Device,

803-014-DD2NF12-3PX-72 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerGlenair
Reach Compliance Codenot_compliant
Connector typeINTERCONNECTION DEVICE
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
【Course Recommendation】+NFC Demonstration and Q&A
[align=left]【Course Recommendation】[font=Times New Roman]+NFC[/font][font=宋体]Demonstration and Q&A[/font][/align][align=left] [/align][align=left]This is a story caused by a baby[font=宋体]fever. The An...
lark100 Wireless Connectivity
Popular Science Sharing - Detailed Explanation of the Working Principles of Starlink Satellites (Episode 5)
How does Starlink communicate with satellites? How does it continuously track satellites? What are the principles behind this?...
zzzy11 RF/Wirelessly
[CC1352P Evaluation] Continue to tinker with SDK examples
[i=s]This post was last edited by cruelfox on 2019-6-4 21:35[/i]  I just downloaded and installed simplelink CC13x2 SDK 2.30 version, and decided not to use CCS for the time being, and just use the co...
cruelfox RF/Wirelessly
Let everyone know my dynamics
I have now settled in EEWORLD. I promised everyone that I would participate in some forum activities and contribute some information. I will, but I am a little busy recently. Let everyone know my dyna...
liang030704 MCU
The system partition is too small, resulting in a prompt that the file system loading failed! Why?
[align=left][color=#454545][font=tahoma, helvetica, arial][48.463757] init (1): /proc/1/oom_adj is deprecated, please use /proc/1/oom_score_adj instead. [ 48.473176] init: cannot find '/system/bin/ser...
gooogleman Embedded System
msp430f149 stack overflow problem
Hello everyone, when I compile a code, a stack overflow warning appears. Theoretically, my data segment is: map file 6 152 bytes of CODE memory 1 268 bytes of DATA memory (+ 56 absolute ) 463 bytes of...
huangxwcz Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 990  1057  1271  1212  1685  20  22  26  25  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号