EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-30V9999

Description
Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil
File Size74KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100-30V9999 Overview

Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil

Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
PRODUCTS UNLIMITED
Model 98 - 3100
series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
16 oz. (455 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
3
Line
Voltage
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
125
100
Resistive
Amps
Rating
30
30
30
35
35
35
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
1.5
3
-
2
-
5
-
-
2
-
5
-
-
3
-
7.5
-
-
Three
Phase
-
7.5
7.5
-
7.5
10
15
20
-
10
10
15
20
-
10
10
20
25
25
3
30
3
240/277
480
600
180
150
120
40
40
40
40
3
240/277
480
600
240
200
160
50
50
50
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
18
6 -15
60
53
6.0
5
7
120
88
20 - 70
60
53
6.0
5
180
208/240
177
40 - 140
60
53
6.0
5
720
277
220
65 - 185
60
53
6.0
5
950
480
384
150 - 270
65
53
6.0
5
3100
Dimensions are shown for
832
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Unboxing record of the new IoT player mPower1203
The mPower1203 I just bought has arrived. Here are some pictures and text to record the unboxing process:The packaging box is quite nice, relatively simple, and the large Egteks logo is quite conspicu...
静若止水99 Mobile and portable
[Question Discussion] How to fake AiYan's pocket experiment kit
AiYan recently released a pocket experiment kit based on 430F5529 and TM4C123. Today I’ll show you some big pictures. 1. First, let me show you an advertisement picture . Currently, I can only touch t...
sunduoze Microcontroller MCU
What's the name of this connector?
[i=s]This post was last edited by cl17726 on 2015-7-2 15:07[/i]Where can I buy it? You can just plug it into USB A or a mobile phone. I don't know the internal structure. I saw it on JD.com. If I post...
cl17726 PCB Design
How can I detect the speed of my arm swinging from left to right?
You want to control the actuator to perform corresponding actions according to the speed of the arm swinging from left to right.At first, I thought of using infrared light to set up two detection poin...
gsy MCU
Ask a few system APIs
WINCE5.0 EVC4 development has several small functions to ask for advice: 1 Set the backlight time. 2 Set the system to standby mode. Thank you...
52FY Embedded System
4. Differential and Integral Circuits
1. The function of the circuit, the difference and similarity with the filter. 2. Analyze the voltage change process of the differential and integral circuits, and draw the voltage change waveform. 3....
wang27349715 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 550  533  1232  2585  1973  12  11  25  53  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号