EEWORLDEEWORLDEEWORLD

Part Number

Search

38-D144D5000

Description
Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil
File Size231KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

38-D144D5000 Overview

Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil

Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
Where can I download free WinCE source code?
I tried several web pages but to no avail. Thanks!...
vviking Embedded System
stm8l-discovery download and debugging issues
The debug mode cannot be started. What is going on? The JP1 jumper cap is connected to on, and both ST-LINK jumpers are also connected. The error message is as follows: Tue May 01 14:38:43 2012: Faile...
emily83_zheng stm32/stm8
【AT-START-F425 Review】 2. Development Environment Construction and Demo Examples
AT-START-F425 provides MDK Keil pack and corresponding Fireware, so development is relatively easy;After installing the pack package, you can see it in the keil option Open the official demo programFi...
kit7828 Domestic Chip Exchange
Is anyone familiar with lithium battery protection IC? If I want to verify these parameters, is there a special instrument? It shouldn't be...
Is anyone familiar with lithium battery protection IC? If you want to verify these parameters, are there special instruments? It shouldn't be verified with an oscilloscope, multimeter, or constant tem...
QWE4562009 Test/Measurement
About WINCE compilation problem
During the compiling process of wince, I only saw that many LIB files were generated, such as netui.lib, but how did it generate DLL files from these LIB files in the end? For example, netui.dll....
liplip Embedded System
Semiconductor material bottleneck
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:59[/i]The bottleneck of semiconductor supporting materials needs to be broken through 2006-7-6  The Semiconductor Equipment and Materia...
ehk Mobile and portable

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1998  2191  1032  2256  635  41  45  21  46  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号