Part Number

Search

38-M144J1000

Description
Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil
File Size231KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

38-M144J1000 Overview

Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil

Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
EEWORLD University ---- Introduction to MSP430FR2311
MSP430FR2311 Introduction : https://training.eeworld.com.cn/course/3864...
hi5 Microcontroller MCU
EDA Software Information
[i=s] This post was last edited by paulhyde on 2014-9-15 09:09 [/i] EDA software information...
renchunyan Electronics Design Contest
Help: 430 and temperature and humidity sensor SHT10
Hello brothers, I recently used 430F149 to connect the temperature and humidity sensor SHT10 to measure temperature and humidity, but I can't read the data. Please help me look at the program. DATA: P...
lovablehua Microcontroller MCU
Detailed explanation of AVR microcontroller ATMEGA88PA-MU
The main features of ATmega88PA-MU are as follows:High performance, low power 8-bit AVR microprocessor Advanced RISC architecture131 instructions – most instructions execute in a single clock cycle 32...
estgdan Microchip MCU
【R7F0C809】Smart alarm clock
[i=s]This post was last edited by tianyingkeji on 2015-11-22 23:48[/i] Communication protocol:Source code:Introduction video: [media=x,500,375]http://v.youku.com/v_show/id_XMTM5MzQ5MDc1Ng==.html[/medi...
tianyingkeji Renesas Electronics MCUs
Please help me, the problem cannot be solved!
Problem description: 1. At the high level of the 4-channel control signal, disconnect S1 and S2, close S3, and charge capacitor C2. 2. At the high level of the 2-channel control signal, disconnect S3 ...
panchhunhui Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2578  2652  552  1516  292  52  54  12  31  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号