EEWORLDEEWORLDEEWORLD

Part Number

Search

4-1415419-2

Description
POWER/SIGNAL RELAY, DPST, MOMENTARY, 2300mW (COIL), 16A (CONTACT), 400VDC (CONTACT), PANEL MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size255KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

4-1415419-2 Overview

POWER/SIGNAL RELAY, DPST, MOMENTARY, 2300mW (COIL), 16A (CONTACT), 400VDC (CONTACT), PANEL MOUNT

4-1415419-2 Parametric

Parameter NameAttribute value
Maximum operating temperature85 Cel
Minimum operating temperature-20 Cel
stateACTIVE
sealRT1
Coil power2300 mW
Relay actionMOMENTARY
Relay functionDPST
Coil resistance4500 ohm
Electrical life250000 Cycle(s)
Manufacturer Series0419
Maximum AC coil current0.0100 A
Maximum AC coil voltage230 V
Maximum AC contact current16 A
Maximum DC contact current16 A
Maximum AC contact voltage250 V
Maximum DC contact voltage400 V
width25 mm
high58.8 mm
length or diameter47.6 mm
Installation featuresPANEL MOUNT
operating hours23 ms
Relay typePOWER/SIGNAL RELAY
release time20 ms
General Purpose Relays
SCHRACK
Rast 5 Power Relay 419 11 (EA/..)
n
n
n
n
n
n
n
2 pole 16 A
Safety mains insulation
Quick connect terminals 6.3 x 0.8 mm
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Snap or screw mounting
Product in accordance to IEC60335-1
Applications
Industrial and domestic appliances, heating controls,
absolute safe power supply disconnection
F0255-CI
Approvals
V
REG.-Nr. 5064 ÜG,
Z
E214024
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Contact gap
Rated frequency of operation with / without load
Contact ratings
Type
Contact
IEC 61810
0419 .. 03
2 NO
0419 .. 04
2 NO
0419 .. 03
2 NO
0419 .. 12 & 13 2 NO
0419 .. 12 & 13 2 NO
0419 .. 12 & 13 2 NO
Load
16 A,
12 A,
20 A,
16 A,
12 A,
20 A,
250 VAC,
250 VAC,
250 VAC,
250 VAC,
400 VAC,
250 VAC,
cosϕ=1
cosϕ=1
cosϕ=1
cosϕ=1
cosϕ=1
cosϕ=1
2 NO
bifurcated contacts
full disconnection
250 / 400 VAC
16 A
25 A
AgCu3
> 3 mm
15 / 600 min
-1
Ambient
temp. [°C]
85°C
85°C
85°C
85°C
85°C
85°C
Cycles
250x10
3
250x10
3
6x10
3
250x10
3
250x10
3
6x10
3
Coil data
Rated coil voltage range DC coil
AC coil
Operative range to IEC 61810 DC coil / AC coil
6...60 VDC
24...400 VAC
1/2
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
10
6
3.5
0.4
50+10%
720
11
10
6.0
0.7
150+10%
667
12
12
7.5
0.9
200+10%
720
13
24
15.0
1.8
800+10%
720
Coil versions, AC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VAC
VAC
VAC
Ohm
VA
01
200.50 / 60 Hz
160.0
15.0
4050+10%
2.2
03 220..240.50 / 60 Hz 187.0
16.0
4500+10%
2.2
04 100..120.50 / 60 Hz
80.0
7.0
850+10%
2.2
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
Oscilloscope is fun, it’s more than just waveform display!
Q: What is an oscilloscope used for? A: Isn't it just to display the waveform? To use some professional terms: The main function of an oscilloscope is to measure the shape of an alternating current or...
okhxyyo Integrated technical exchanges
Feiling FETT507-C core board 4-way AHD camera implementation solution
This article explains the application of transplanting Huawei-ME909S-4G module to the domestic A40i development board . This article is mainly applicable to the Feiling OKA40i platform Linux 3.10.65 o...
小螃蟹呀 ARM Technology
Asynchronous Circuit Design Design Principles - System Perspective
Can anyone share the PDF of Asynchronous Circuit Design Principles - System Perspective?...
1206901571 FPGA/CPLD
DSP ccs2 C5000 compiles SUBC instruction to implement division
Solve y=(ax^2-bx+c)/(dx+e) by programming, and put the quotient and remainder in the data memory 1000H and 1001H units respectively. (1) Given a=8, b=6, c=10, d=7, e=9, x=5, find y. (2) Given a=0.9, b...
Aguilera DSP and ARM Processors
Embedded multi-core and virtualization development direction
Multi-core is a hot topic now. Even our company's servers have dual-core CPUs, but the running speed is not as good as that of single-core CPUs. Is 1+1<1? The problem is that the multi-core function i...
gauson Embedded System
TI Current Sense Amplifier Selection Questions
[align=left][color=#000][font=Arial, Helvetica, sans-serif][size=12px]I want to detect the input voltage of 36V and the maximum current of 10A. Which current detection amplifier should I choose? Do yo...
dianhang Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2265  1320  1135  135  1551  46  27  23  3  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号