EEWORLDEEWORLDEEWORLD

Part Number

Search

CB-1043B-39

Description
OFF-DELAY RELAY, DPDT, MOMENTARY, 3000mW (COIL), 10A (CONTACT), 30VDC (CONTACT), 0.1-10s, SOCKET MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size45KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

CB-1043B-39 Online Shopping

Suppliers Part Number Price MOQ In stock  
CB-1043B-39 - - View Buy Now

CB-1043B-39 Overview

OFF-DELAY RELAY, DPDT, MOMENTARY, 3000mW (COIL), 10A (CONTACT), 30VDC (CONTACT), 0.1-10s, SOCKET MOUNT

CB-1043B-39 Parametric

Parameter NameAttribute value
Minimum operating temperature-10 Cel
Maximum operating temperature55 Cel
stateActive
Relay typeOFF-DELAY RELAY
Minimum adjustable delay0.1000 s
Maximum adjustable delay10 s
width45.2 mm
high74.6 mm
length or diameter61.1 mm
Maximum AC coil current0.0250 A
coil_input_supply_typeAC
coil_power__mw_3000
Maximum AC coil voltage120 V
contact_ac_max_rating_r_load10A@240VAC
Maximum AC contact current10 A
Maximum DC contact current10 A
contact_dc_max_rating_r_load10A@30VDC
contact_output_supply_typeAC/DC
Maximum AC contact voltage240 V
Maximum DC contact voltage30 V
Electrical life100000 Cycle(s)
Manufacturer SeriesCB
Installation featuresSOCKET MOUNT
Dimensions61.1mm X 45.2mm X 74.6mm
eference_standardCSA; UL
Relay actionMOMENTARY
Relay functionDPDT
Terminal typeSNAP-ON
Catalog 1308242
Issued 3-03
P&B
CB
series
CMOS IC Time Delay Relay
Choice of timing modes
– Delay on operate
– Delay on release
– Interval on with or without control switch
Knob adjustable
10A output relay with SPDT or DPDT contacts
Various models time from 0.1 sec. to 100 min.
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Timing Modes
Delay on operate
– Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
INPUT
VOLTAGE
ON
OFF
TIME
Contact Data @ 25
°
C
Arrangements:
2 Form C (DPDT), except 8-pin delay on release model
has 1 Form C (SPDT).
Material:
Silver-cadmium oxide alloy.
Rating:
10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
1/3 HP @ 120VAC.
Expected Mechanical Life:
10 million operations.
Expected Electrical Life:
100,000 operations, min., at rated load.
N.O. RELAY ON
CONTACTS OFF
Delay on release
– Input voltage must be applied continuously to operate
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
CONTROL
SWITCH
ON
OFF
TIME
Initial Dielectric Strength
Between Open Contacts:
500V rms, 60 Hz.
Between All Other Conductors:
500V rms, 60 Hz.
N.O. RELAY ON
CONTACTS OFF
Interval on (without control switch)
– The relay energizes and timing
begins when input voltage is applied. At the end of the time delay period
the relay will de-energize. Reset is accomplished by removing, then
reapplying, the input voltage.
INPUT
VOLTAGE
ON
OFF
Input Data @ 25
°
C
Voltage:
24 and 120VAC, and 12 and 24VDC.
Power Requirement: AC Types:
Typically less than 3 VA.
DC Types:
Typically less than 3 W.
Transient Protection:
Yes.
Reverse Voltage Protection:
Yes.
Input Voltages & Limits @ 25
°
C
N.O. RELAY ON
CONTACTS OFF
TIME
Voltage
Type
AC
DC
Nominal
Voltage
24
120
12
24
Minimum
Voltage
20
105
11
20
Maximum
Voltage
28
130
13
32
Interval on (with control switch)
– Input voltage must be applied
continuously to operate the internal relay. The relay energizes and timing
begins when the external switch is closed. At the end of the time delay
period the relay will de-energize. Reset is accomplished by opening and
reclosing the control switch.
CONTROL
SWITCH
ON
OFF
Note:
DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
N.O. RELAY ON
CONTACTS OFF
TIME
Environmental Data
Temperature Range: Storage:
-55°C to +85°C.
Operating:
-10°C to +55°C.
Timing Specifications
Timing Ranges:
From 0.1 to 1.0 sec. through 10 to 100 min.
Timing Adjustment:
Knob adjustable.
Tolerance (for AC units add
±
1/2 cycle 60 Hz.):
Knob Adj. Types:
–0, +30% of max. specified at high end of timing range;
min. specified, or less, at low end.
Fixed Types:
±
10%.
Res. Adj. Types:
±
10% at high end of timing range; min. specified, or less,
at low end.
Delta Time (for AC units add
±
1 cycle 60 Hz.):
±
10%.
Repeatability (for AC units add
±
1 cycle 60 Hz.):
±
2%.
Release Time:
60 ms, typ.; 100 ms, max.
Recycle Time:
60 ms, typ.; 100 ms, max.
Dimensions are shown for
Mechanical Data
Termination:
8- or 11-pin octal style plug.
Enclosure:
White plastic case. Knob adjustable types have dial scale for
reference only.
Sockets:
Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight:
6 oz. (170g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1228
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2883  1685  2453  2668  114  59  34  50  54  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号