EEWORLDEEWORLDEEWORLD

Part Number

Search

3EK1

Description
120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size472KB,4 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

3EK1 Online Shopping

Suppliers Part Number Price MOQ In stock  
3EK1 - - View Buy Now

3EK1 Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

3EK1 Parametric

Parameter NameAttribute value
working frequency50/60 HZ
stateTRANSFERRED
Installation typePanel mounting
DimensionsL85.1XB71.4XH29.5 (mm)/L3.35XB2.81XH1.16 (inch)
Manufacturer SeriesK
high capacity2250 V
filter typeSingle Phase EMI Filter
Rated current10 A
Rated voltage120 V
Maximum leakage current0.2100 mA
Maximum insertion loss frequency45 dB
Minimum insertion loss frequency8 dB
CORCOM Product Guide
General Purpose RFI Power Line Filters — Ideal for High Impedance Load
K Series
VK6
VK7/EK7
UL Recognized
CSA Certified
VDE Approved
VK1/EK1
VK3/EK3
K Series
The K series RFI power line filters are general purpose
common-mode and differential-mode filters. They are
effective in the control of line-to-line as well as line-to-
ground RFI interference. The K series RFI filters are
particularly suited in applications where pulsed, continuous
and/or intermittent RFI interference is present. The EK
models meet the very low leakage current requirements of
VDE portable equipment, and (120 Volt) UL544 non-patient
medical equipment.
Specifications
Maximum leakage current,each line-to-ground
VK Models
@ 120 VAC 60 Hz:
.5 mA
@ 250 VAC 50 Hz:
1.0 mA
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage (max.):
Minimum insertion loss in dB:
EK Models
.21 mA
.36 mA
2250 VDC
1450 VDC
50/60 Hz
250 VAC
Electrical Schematics
LINE
LOAD
Line-to-ground in 50 ohm circuit
Current
Rating
.15
Frequency-MHz
.5
1
5
10
30
19
19
22
29
19
38
28
28
28
35
25
50
42
42
32
45
38
50
45
45
39
45
40
30
50
50
50
35
50
45
30VK6C Model
(Inductor in Ground Line)
LINE
LOAD
VK Models
1A, 3A
15
2A, 5A, 10A
6
20A, 30A, 40A
6
60A
6
EK Models
1A, 3A
15
2A, 5A, 10A, 20A 8
60VK6 Model
LINE
LOAD
Resistor location for reference only.
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating
.15
.5
1
5
10
VK, EK Models
1A, 3A
48
55
50
30
30
50
2A, 5A, 10A
50
30
30
6
6
20A
VK Models
30A, 40A
2
40
60
65
57
60A
13
49
67
57
53
EK Models
30
50
30
6
6
30A
30
35
30
30
55
53
30
.
74
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
RTOS on G2553
I want to ask the master to transplant small rtos to g2553. If 51 can be used, 2553 can definitely be used. Thank you~...
zdd563 Microcontroller MCU
Classic Transformer Design Notes
Very classic...
tonytong Power technology
EEWORLD University Hall ---- Computer Control Technology Harbin Institute of Technology Guo Ben
Computer Control Technology Harbin Institute of Technology Guo Ben : https://training.eeworld.com.cn/course/5652ContentsChapter 1 Introduction1.1Overview of Computer Control Systems1.2Types of Compute...
木犯001号 Industrial Control Electronics
The first operation of the microcontroller is very slow.
The microcontroller uses stc12c5a60s2. It is very slow when it is first run. It takes about 40 to 50 seconds to send data. Can someone help me find out what went wrong?...
朱友军 51mcu
Repost an ADC grounding question and answer. It is very similar to ADI's idea.
[i=s]This post was last edited by dontium on 2015-1-23 13:35[/i]Q: I have read your data sheets and application notes and attended your technical seminars, but I am still a little confused about how t...
ch0721 Analogue and Mixed Signal
TI's high-performance power solution for Altera Arria II G using DC/DC converters
Note: These reference designs detail design considerations for power solutions using DC/DC converters targeting the Arria II GX....
莫妮卡 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 120  1468  16  2699  1667  3  30  1  55  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号