120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size393KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

3EQ8M Online Shopping

Suppliers Part Number Price MOQ In stock  
3EQ8M - - View Buy Now

3EQ8M Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

3EQ8M Parametric

Parameter NameAttribute value
working frequency50/60 HZ
stateACTIVE
Installation typePANEL MOUNT
DimensionsL153.2XB52.6XH57.9 (mm)/L6.03XB2.07XH2.28 (inch)
Manufacturer SeriesQ
high capacity2250 V
filter typeSINGLE PHASE EMI FILTER
Rated current20 A
Rated voltage120 V
Maximum leakage current0.7300 mA
Maximum insertion loss frequency70 dB
Minimum insertion loss frequency6 dB
CORCOM Product Guide
Highest Performance RFI Filters for Switching Power Supply
Emissions down to 10 kHz
Q Series
Q8-6A
UL Recognized
CSA Certified
VDE Approved
Q1
Q3
Q Series
This series of RFI power line filters has been developed
specifically for switching power supplies and is designed to
be all the power line filtering needed to control conducted
emissions
all the way down to 10kHz.
High attenuation is
provided for both common mode and differential mode
interference throughout the frequency range with no
degradation of performance due to the large peak currents
drawn by switching power supplies.
These filters are an ideal choice for applications that must
meet emission limits below 150kHz, as well as the
mandated limits above 150kHz. In most cases they will
bring such equipment into compliance with the B-level
limits of CISPR 22. They are also well suited for bringing
ISM equipment (such as ultrasonic cleaners) into
compliance with the limits of FCC Part 18, from 10kHz to
30MHz.
The EQ models meet the very low leakage current
requirements VDE portable equipment, and (120 Volt)
UL544 non-patient medical equipment. The VQ models
offer higher common mode performance at the expense of
higher leakage current, but still meet the leakage current
limits of UL, CSA, and VDE non-portable equipment.
Specifications
Maximum leakage current,each line-to-ground
VQ Models
@ 120 VAC 60 Hz (3A, 20A):
.73 mA
@ 120 VAC 60 Hz (6A):
@ 250 VAC 50 Hz (3A, 20A):
1.27 mA
@ 250 VAC 50 Hz (6A):
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage (max.):
Rated current:
3VQ/3EQ
6EQ
20EQ1/20VQ1
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
3VQ
3EQ
6EQ
20EQ1
20VQ1
LOAD
EQ Models
.22 mA
.29 mA
.38 mA
.51 mA
2250 VDC
1450 VDC
50/60 Hz
250 VAC
3A
6A
20A
.01
22
22
26
6
6
Frequency–MHz
.02 .05 .15 .5
1
5
27
27
31
10
3
37
36
20
8
17
50
47
68
39
52
55
47
72
60
65
55
43
72
65
70
55
45
65
65
70
10
50
45
65
65
70
30
55
45
65
55
70
Electrical Schematics
3EQ & 3VQ Models
LINE
Line-to-line in 50 ohm circuit
Current
Rating
3VQ
3EQ
6EQ
20EQ1
20VQ1
.01
1
1
6
15
15
Frequency–MHz
.02 .05 .15 .5
1
5
17
17
10
20
20
42
42
43
20
20
65
65
70
46
46
75
75
75
65
65
75
75
75
70
70
60
65
65
65
65
10
65
65
55
60
60
30
65
60
55
60
60
6EQ & 20EQ Models
LINE
LOAD
Line Cord
Resistor location for reference only.
Line Cord No. GA400: 7 1/2 foot, 3-conductor line cord
to mate with Q8 models.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
82
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Relationship between output voltage holding time and capacitor capacity
[color=#000][font=Arial, 宋体, Helvetica, sans-serif][size=12px]The output voltage holding time refers to the time the output voltage is held after the input of the power supply circuit is stopped. The ...
wstt Power technology
Question: What is the most common and simple solution for MP3?
I recently read some information about MP3 on the Internet. The VS10 series solution is quite common. You put songs into a memory card. Then use a single-chip microcomputer to read it out and encode i...
youluo Integrated technical exchanges
Convert an input sine wave signal into a triangular wave with the peak value, frequency and phase unchanged.
How to do this, I have no idea, can someone give me some ideas- -! :loveliness:...
278023330 Microcontroller MCU
It is recommended to change the default language of the code inserted when posting to C language
The forum has been very powerful recently. Finally, we can format the inserted code. The code sent out by using code formatting looks good, and it is also much more convenient to post (in the past, we...
littleshrimp Suggestions & Announcements
How to increase the energy of LC resonant circuit?
I want to increase the energy of the LC resonant circuit. Is there any way to do it? I would like to ask my friends if there is any way to increase the energy of the resonant circuit?...
量子阱 Analog electronics
Timer A cannot capture the 1 Hz frequency, how to deal with it?
I use msp430f5529 to set the capture mode, capture square waves, and calculate the frequency, but I can't capture the 1HZ frequency. What should I do? Please give me some advice...
jianhong0425 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1335  1339  1502  980  2175  27  31  20  44  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号