EEWORLDEEWORLDEEWORLD

Part Number

Search

V23057-B2013-A402

Description
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.075A (COIL), 6VDC (COIL), 500mW (COIL), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size187KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

V23057-B2013-A402 Overview

POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.075A (COIL), 6VDC (COIL), 500mW (COIL), THROUGH HOLE-STRAIGHT MOUNT

V23057-B2013-A402 Parametric

Parameter NameAttribute value
Maximum operating temperature70 Cel
Minimum operating temperature-40 Cel
stateACTIVE
sealRT3
Coil power500 mW
Relay actionMOMENTARY
Relay functionSPDT
Coil resistance80 ohm
terminal coatingNOT SPECIFIED
Manufacturer SeriesV23057
Maximum DC coil current0.0750 A
Maximum DC coil voltage6 V
Maximum AC contact current8 A
Maximum AC contact voltage250 V
DC coil operating voltage4 V
DC coil release voltage0.6000 V
width25 mm
high10.8 mm
length or diameter28 mm
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours10 ms
Relay typePOWER/SIGNAL RELAY
release time6 ms
Terminal typeSOLDER
General Purpose Relays
Power PCB Relay Card E
I
I
I
I
I
I
1 pole 8 A, 1 CO or 1 NO contact
4 kV coil-contact
Vertical and horizontal version
Version with bifurcated contacts
Wash tight
RoHS compliant (Directive 2002/95/EC)
as per product date code 0426
Applications
I/O modules, heating control, timers
F0151-B
Approvals
V
REG.-Nr.
of
5146,
Z
on request
E214024
Technical data approved types
Contact data
Contact configuration
1CO or 1NO
Contact set
single cont.
single cont.
twin contact
Type of interruption
micro disconnection
Rated current
8A
5A
5A
Rated voltage / max.switching voltage AC
240/400 VAC
Maximum breaking capacity AC
2000 VA
1250 VA
1250 VA
Limiting making capacity, max 4 s, duty factor 10%
15 A
Contact material
AgCdO; AgNi20 AgNi0,15
AgNi0,15
Mechanical endurance
20x10
6
cycles
Rated frequency of operation with / without load
6 / 1200 min
-1
Contact
Type
-A102
-A102
-A402
ratings
Load
4 A, 30 VDC, resistive
1 A, 24 VDC, inductiv L/R=40ms
1 A, 230 VAC, cosϕ=0.4
Cycles
2x10
6
2x10
5
5x10
5
Coil data
Rated coil voltage range DC coil
Coil power DC coil
6...60 VDC
450...500 mW
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
001
6
4.0
0.6
80+10%
450
002
12
8.0
1.2
330+10%
436
006
24
16.0
2.4
1200+15%
480
013
48
32.0
4.8
4700+15%
490
023
60
40.0
6.0
7200+15%
500
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
Help: How to package the image as a whole
Dear experts, I have a question: Assuming that the application is finally compiled and linked to generate the app.bin.gz file, the file will be directly burned into the root directory of the flash. In...
ailikelhl Embedded System
Confusion in SPI communication
In the SPI communication between the simulated microcontroller and 25AA040, the timing of 25AA040 reading bytes is output on the falling edge of the clock, but in the program, the clock line is first ...
逆时针302 51mcu
[SAMR21 New Gameplay] Summary
[i=s]This post was last edited by dcexpert on 2019-10-18 11:36[/i]Different from the traditional development method, it does not require IDE and compiler. It uses Python and graphical programming to d...
dcexpert MicroPython Open Source section
STC built-in ad conversion problem
In my STC built-in AD, ADC_FLAG is set to 1, but the data I send out through the serial port is always FF. I don't know why, even if my voltage is only 2V. I am confused....
zxhnet Embedded System
Talk about the pressure faced by test engineers
Test engineers, here’s a question: In the past five years, what changes have taken place in your work tasks and intensity? Where does the pressure manifest itself? What are your expectations for futur...
思潇 Test/Measurement
【TI's First Low Power Design Competition】Energia Installation
[i=s]This post was last edited by ddllxxrr on 2014-10-17 09:05[/i] I downloaded Energia a long time ago, but I was busy with other things these two days and didn't unzip it. I thought it should be ver...
ddllxxrr Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2558  747  1391  2534  944  52  16  29  20  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号