DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
CategoryPower/power management    The power supply circuit   
File Size137KB,3 Pages
ManufacturerRECOM
Environmental Compliance
Download Datasheet Parametric View All

RK-1209S/H Overview

DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4

RK-1209S/H Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerRECOM
Parts packaging codeMODULE
package instructionSIP, SIP4/7,.2
Contacts7/4
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC UNREGULATED POWER SUPPLY MODULE
Maximum input voltage13.2 V
Minimum input voltage10.8 V
Nominal input voltage12 V
JESD-30 codeR-PSIP-T7
length19.65 mm
Maximum load regulation10%
Number of functions1
Output times1
Number of terminals7
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum output current0.111 A
Maximum output voltage9.45 V
Minimum output voltage8.55 V
Nominal output voltage9 V
Package body materialPLASTIC/EPOXY
encapsulated codeSIP
Encapsulate equivalent codeSIP4/7,.2
Package shapeRECTANGULAR
Package formIN-LINE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
Maximum seat height10.45 mm
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal formTHROUGH-HOLE
Terminal pitch2.54 mm
Terminal locationSINGLE
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output1 W
Fine-tuning/adjustable outputNO
width7.05 mm
Features
Unregulated
Converter
Description
3kVDC or 4kVDC Isolation
Optional Continuous Short Circuit Protected
Custom Solutions Available
UL94V-0 Package Material
Efficiency to 84 %
Suitable for IGBT Applications
ECONOLINE
DC/DC-Converter
with 3 year Warranty
The RK and RH Series DC/DC-Converter complements Recom’s industrial range of converters
with very high isolations of 3KV and 4kVDC. The extended operating temperature range
covering –40°C to +90°C is a standard feature. The converters are EN-60601-1 certified,
making them suitable for medical as well as IGBT driver applications.
Selection Guide
Part
Number
SIP 7
RK-xx05S*
RK-xx09S*
RK-xx12S*
RK-xx15S*
RH-xx05D*
RH-xx09D*
RH-xx12D*
RH-xx15D*
(4kV)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
Input
Voltage
(VDC)
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
Output
Voltage
(VDC)
5
9
12
15
±5
±9
±12
±15
Output
Current
(mA)
200
111
84
66
±100
±56
±42
±33
Efficiency
(%)
70-78
70-80
78-82
80-82
74-78
76-79
78-84
80-84
Max
Capacitive
Load
(1)
1000µF
1000µF
470µF
470µF
±470µF
±470µF
±220µF
±220µF
1 Watt
SIP7
Single
&
Dual
Output
RH-xx1509D* (H)
5, 12, 24
+15/-9
+33/-56
70-81 +220/-470µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RK-0505S/P, RK-0505S/HP
2011/65/EU
6/6
RoHS
E-358085
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
5V output type
9V, 12V, 15V, 24V output types
RH-xx1509D
Single output types
Dual output types
RK types
RH types
RK-xx1509D
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage
Isolation Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection, without derating)
Storage Temperature Range
Relative Humidity
H-Suffix
H-Suffix
(tested for 1 second)
(rated for 1 minute***)
(tested for 1 second)
(rated for 1 minute***)
RK types
RH types
±10%
±5%
1.2%/1% of Vin typ.
15% max.
10% max.
10% max.
100mVp-p max.
±75mVp-p max.
EN-60950-1 Certified
IEC/EN-60601-1 Certified**
UL-60950-1 Certified**
** +15/-9 Version excluded
RK_RH
Derating-Graph
(Ambient Temperature)
100
80
50kHz min. / 100kHz typ. / 105kHz max.
57kHz min. / 100kHz typ. / 105kHz max.
50kHz min. / 88kHz typ.
70% min. / 80% typ.
Specifications valid for 10% minimum load only.
3000VDC
Output Power (%)
1500VAC / 60Hz
4000VDC
2000VAC / 60Hz
20pF min. / 75pF max.
20pF min. / 65pF max.
15 GΩ min.
1 Second
Continuous
-40°C to +90°C (see Graph)
-55°C to +125°C
95% RH
continued on next page
60
40
20
0
Safe Operating Area
90 100
95
Operating Temperature °C
-40
0
50
150
***Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 0/2015
E-57

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2664  2501  1068  282  2563  54  51  22  6  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号