3.5 kV
Kilovac HC-1
Kilovac HC-3
No Load Switching
Make & Break Load Switching
Features:
HC-1
Widely used for RF applications
Vacuum dielectric for low leakage current
applications
Copper contacts for high current capability
Not designed for power switching
Meets requirements of MIL-R-83725
QPL version available, M83725/5-001
HC-3
Tungsten contacts for long life when power
switching
Vacuum dielectric for power switching low
current loads
Kilovac HC-5
Make Only Load Switching
Features:
Gas-filled for make only power switching
SF-6 gas filled for capacitive discharge
applications
Part Number
Contact Arrangement ..........................................................
PRODUCT SPECIFICATIONS
HC-1
Unit
SPDT
C
kV Peak
kV Peak
COIL DATA
HC-3
SPDT
C
5
3.5
-
-
-
18
-
-
-
500
-
-
0.02
6
6
50
55-2000
-55 to +125
2
1
HC-5
SPDT
C
5
3.5
-
-
-
8
-
-
-
500
-
-
0.50*
6
6
50
55-2000
-55 to +125
1
1
Nominal, Volts dc
Pickup, Volts dc, Maximum
Drop-Out, Volts dc
Coil Resistance (Ohms ±10%)
12
8
.5 - 5
80
26.5
16
335
115
80
6000
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ...................................................
Rated Operating Voltage .....................................................
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum ...............................
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance ............................................................
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 Gs Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 10
6
) ....................................
Weight, Nominal ..................................................................
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
1 - 10 5 - 50
5
3.5
2.5
2
1.5
Ratings listed are for 25°C, sea level conditions
PART NUMBER SELECTION
Sample Part No.
HC -
Model
1
3
5
Coil Voltage
Blank = 26.5Vdc
/12Vdc = 12Vdc
/115Vdc = 115Vdc
1
/12Vdc
Amps
25
14
9
7
500
pF
2
2.5
Ohms
ms
ms
G's Peak
Hz
o
0.01
6
6
50
55-2000
-55 to +125
2
1
C
cycles
oz
25
CII Technologies
/ P.O. Box 4422 / Santa Barbara, CA 93140 /
ph
805.684.4560 /
fax
805.684.9679
/
e-mail
info@kilovac.com /
website
www.ciitech.com