2410 Series - 5-Pin Multi-Stage Protector (MSP垄莽)
File Size157KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet View All

2410-39-G-BC-T Overview

2410 Series - 5-Pin Multi-Stage Protector (MSP垄莽)

Features
Patented Multi-stage protection (MSP
®
)
Balanced TRIGARD
®
Meets test requirements of Telcordia
Patented Switch-Grade Fail-Short Device
Quick response and high energy handling
Ideal for high-speed networks in high
exposure environments
Listed per UL 497 (File: 53117)
GR 974, GR1361, SBC SR 5165 and
RUS PE-80
Telcordia Analysis report DA-1547
Solid brass, gold-plated pins
Test point access option
Sealed option for harsh environments
2410 Series - 5-Pin Multi-Stage Protector (MSP
®
)
Bourns
®
5-Pin Multi-Stage Protector (MSP
®
) is the latest generation telecommunications protector for high performance and long life
in overvoltage protection of copper pair voice-band and high-speed data circuits. Bourns MSP
®
combines the advantages of gas tube
and solid state protection while integrating three advanced technologies: a proprietary high-efficiency gas discharge tube,
precision matched metal oxide varistors and a patented Switch-Grade Fail-Short mechanism. The Switch-Grade Fail-Short
mechanism ensures superior thermal protection with fast acting, highly reliable response to thermal overload conditions. This
combined technology provides lower capacitance, higher reliability and longer life than competitive hybrid technologies.
Bourns
®
2410 can be used universally for POTS and high speed data, e.g. ISDN, ADSL, ADSL2+, VDSL, VDSL2, other xDSL
protocols and high speed Ethernet. Bourns
®
MSP
®
technology provides unparalleled overvoltage protection with low loss on paired
copper communications circuits. The 2410 series is the most economical, reliable and effective choice for overvoltage protection of
copper pair circuits.
Characteristics
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
DC Breakdown ............................................................................................................................................... 300-400 V
AC Breakdown @ 60 Hz ................................................................................................................................ 300-400 V
Impulse Breakdown
100 V/μs .................................................................................................................................................... 600 V
1000 V/μs .................................................................................................................................................. 650 V
Insulation Resistance @ 100 Vdc .................................................................................................................. >1 GΩ
Insertion Loss @ 100 MHz ............................................................................................................................. <0.4 dB
1
Return Loss @ 100 MHz ................................................................................................................................ >14 dB
1
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. 10 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz ................................................................................................ 20 pF typical
Impulse Reset
5
52 V, 260 mA ............................................................................................................................................. <10 ms
135 V, 200 mA ........................................................................................................................................... <10 ms
150 V, 200 mA ........................................................................................................................................... <150 ms
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
10 to 100 A, 10/1000 μs ............................................................................................................................ >3000 operations
2
300 A, 10/1000 μs ..................................................................................................................................... >1000 operations
2
500 A, 10/1000 μs ..................................................................................................................................... >1000 operations
4
2,000 A, 10/250 μs .................................................................................................................................... >100 operations
2
5,000 A, 20/100 μs .................................................................................................................................... >10 operations
2
20,000 A, 8/20 μs ...................................................................................................................................... >10 operations
4
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
0.5 A rms continuous ................................................................................................................................. >30 seconds
1 A rms, 1 second, 600 ft. cable ................................................................................................................ >60 seconds
1 A rms, 1 second, 1 mile cable ................................................................................................................. >60 operations
10 A rms, 1 second .................................................................................................................................... >5 operations
65 A rms, 11 cycles .................................................................................................................................... >1 operation
3
120 A rms, 0.1 second ............................................................................................................................... 1 operation
High Current Capability and Thermal Operation (Tip and Ring to Ground,
Vented or Non-Vented Gas Tube) .................................................................................................................. >30 A rms, simultaneously
Storage and Operating Temperature .............................................................................................................. -55 to +85 °C
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.
Telcordia Technical Analysis Report DA-1547.
Notes:
1
Tested according to Category 5 requirements
2
Exceeds Telcordia (Bellcore) GR 1361
3
Surpasses Telcordia GR 974
4
RUS (REA) PE-80
5
Network applied
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
It's the weekend, get ready for a big win
I'm usually too busy to have time... I finally made it to the weekend, I'm so excited... I'm ready to attack the hygrometer and win the battle! O(∩_∩)O Hahaha~:sexy:...
drjloveyou DIY/Open Source Hardware
Learn about the car laptop power supply circuit
[font=Verdana][color=black]It can be used for notebook power supply, car equipment, etc., so I share it with you here. This power supply has two batches, with different input voltages of 12V and 24V, ...
qwqwqw2088 Analogue and Mixed Signal
Part-time MCU, DSP, ARM, FPGA, CPLD chip program cracking
I am good at cracking MCU, DSP, ARM, FPGA, CPLD programs and copying circuit boards, drawing schematics and PCBs, and the success rate of cracking is very high. At the same time, I also undertake the ...
morning30 ARM Technology
Design of ultrasonic distance measuring sensor system
Working principle of 51 MCU timer interrupt Working principle of ultrasonic sensor, timing diagram, distance calculation Relationship between ultrasonic sound speed and temperature Display distance th...
工业电子77 51mcu
Does anyone have the package of MC1319?
Same topic, thank you very much... My email address issageknight@126.com...
fastwind2000 NXP MCU
Which domestic oscilloscope is better?
There are too many domestic digital oscilloscopes now. Which brand is better?...
ailibieku Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1545  301  1447  597  1376  32  7  30  13  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号