EEWORLDEEWORLDEEWORLD

Part Number

Search

RTS-2412/H3

Description
Analog Circuit
CategoryAnalog mixed-signal IC    The signal circuit   
File Size179KB,4 Pages
ManufacturerRECOM
Download Datasheet Parametric View All

RTS-2412/H3 Overview

Analog Circuit

RTS-2412/H3 Parametric

Parameter NameAttribute value
MakerRECOM
package instruction,
Reach Compliance Codeunknown
Features
Unregulated
Converters
Description
1kVDC and 3kVDC Isolation Options
Approved for Medical Applications
Suitable for Automated Assembly
High Power Density
Optional Continuous Short Circuit Protection
Efficiency to 8 5 %
ECONOLINE
DC/DC-Converter
Compared to standard 2 Watt packages, space savings of 80% and 77% respectively are achieved by these RTS & RTD
2 Watts SMD-Miniature DC/DC Converters. They have been specifically designed for applications where board space is
at a premium since these 2 Watt converters have only a slightly larger foot print than conventional 1 Watt converters.
With efficiencies up to 85%, external cooling is not needed, as the full output power is available over the operating
temperature range -40°C to +85°C. All converters have an I/O-Isolation of 1kVDC, or optionally 3kV, making them
suitable for many industrial and medical applications.
Selection Guide
Part
Number
SMD
RTS**-xx3.3
RTS**-xx05
RTS**-xx09
RTS**-xx12
RTS**-xx15
RTS**-xx24
RTD**-xx05
RTD**-xx09
RTD**-xx12
RTD**-xx15
Input
Voltage
(VDC)
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
9
12
15
24
±5
±9
±12
±15
Output
Current
(mA)
606
400
222
167
133
83
±200
±111
±83
±66
Efficiency
(%)
70-75
80-85
80-85
80-85
80-85
80-85
70-75
75-78
75-83
75-85
2 Watt
SMD
Single
&
Dual Output
(3kV)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
EN-60950-1 Certified
(All Suffixes)
EN-60601-1 Certified
(Suffix H3)
RTD**-xx24 (H)
5, 12, 15, 24
±24
±42
78-85
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RTS-0505/P, RTD-0505/HP
* add suffix -R for tape&reel packing e.g.
RTS-0505-R
. For more details see Tapes Section.
RTS-RTD
Case and Pinning Options (note restrictions on /H option)
RTS** : ** without marking denotes 5 pins out of 8 fitted (includes /H option)
** with marking 8 denotes 8 pins out of 8 fitted (/H option not available)
RTD** : ** without marking denotes 6 pins out of 10 fitted (includes /H option)
** with marking 10 denotes with 10 pins out of 10 fitted (/H option not available)
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
No Load Power Consumption
RTS typ.
RTD typ.
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
±10%
±5%
1.2%/1% of Vin max.
20% max.
15% max.
10% max.
150mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
70% min. / 80% typ.
124mW min. / 186mW typ. / 350mW max.
159mW min. / 192mW typ. / 350mW max.
cont.
www.recom-international.com
REV:0/2009
E-39
Refer to Application Notes
Can vxworks compile a dynamic library, that is, can it generate a .so file?
Can vxworks compile a dynamic library, that is, can it generate a .so file? I am using two compilation environments, tornado2.2 and Wind River. Previously, we compiled libraries by writing static libr...
zyjnh005 Real-time operating system RTOS
Strain Gauges
A dynamic force is loaded on one end of the cantilever beam, and a strain gauge is used to measure the strain of the cantilever beam. To ensure that the strain gauge can work normally, what is the max...
a问问 Sensor
Discussion on AC and DC conversion issues
I hope all the power experts will think about the four basic power conversion problems: DC to DC, AC to DC, DC to AC, and AC to AC, including how to convert, what devices or components to use for conv...
piggyfeng Power technology
51 MCU floating point calculation error problem
I would like to ask, after using stc89c52 to do floating point calculations, there is sometimes an error of 0.01 when taking 2 decimal places. What is the accuracy of floating point calculations of si...
zzxuzz 51mcu
MSP430F5529 Power Management Module
Power management and monitoring is a very complex part that is difficult to master. It not only involves the selection of source mode, but also involves complex interrupts and how to handle interrupts...
Jacktang Microcontroller MCU
I want an expert to help me write an intelligent light-controlled street lamp system based on 51 single-chip microcomputer
RT, it would be better if there is a circuit diagram, thanks in advance. . If you have any, please send them to tianya3849@163.com :Cry:...
tianya3849 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1059  1168  399  2850  1830  22  24  9  58  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号