Part Number

Search

F.MA.01A.04.GA

Description
Mains Power Connector, 1A, 250VAC, Male
CategoryThe connector    The connector   
File Size123KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MA.01A.04.GA Overview

Mains Power Connector, 1A, 250VAC, Male

F.MA.01A.04.GA Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
Other featuresSTANDARD: IEC 60320
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceNO
MIL complianceNO
Power Connector Ratings1A, 250VAC
Manufacturer's serial numberF.MA
OptionsGENERAL PURPOSE
Total number of contacts1
IEC Inlet Filters
With fuse holders and mains switch
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus a unipolar or bipolar
rocker switch.
Designed for use in business, consumer and medical equipment,
VDU’s, vending machines and many other general purpose
applications.
F.MA-F.MB-F.MC-F.MD
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Unipolar or bipolar rocker switch
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
1 (F.MA-F.MC) or 2 (F.MB-FMD) fuse holders for
fuses 5 x 20mm (IEC) or 6.3 x 32mm (US),
unipolar (F.MA-F.MB) or bipolar (F.MC-F.MD)
rocker switch;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 4.8 x 0.8mm for rocker switch terminals;
ground terminal connected to case.
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
07 = Fuse 5 x 20mm
14 = Fuse 6.3 x 32mm
A = 1 Fuse + unipolar rocker switch
B = 2 Fuses + unipolar rocker switch
C = 1 Fuse + bipolar rocker switch
D = 2 Fuses + bipolar rocker switch
F.MA.
F.MC.
F.MD.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MB. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MA.01A.01.07.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Rocker switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
6(4)A / 250Vac (Rated current),
50000 on-off operations;
10(4)A / 250Vac (Rated current),
10000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Leakage current (I
L
):
at 220V, 50Hz, max value
Approvals
27
[MPS Mall Big Offer Experience Season] Unboxing
MPS's main product is power management. I took advantage of the event to participate. The express delivery is really fast, and the domestic warehouse is SF Express. The packaging surprised me, it was ...
dql2016 Power technology
Problems sending custom frames over Ethernet
I want to send a custom frame directly through Ethernet. Now I encounter some problems when using muxSend function. First, cookies only need to call muxBind and get the return value? Second, I am not ...
feeler Embedded System
Share the shake stick program of MSP 430 microcontroller (install two mercury switches)
, Helvetica, SimSun, sans-serif] ................................\........\wei5.dbgdt[/font] [font=Tahoma, Helvetica, SimSun, sans-serif] ................................\........\wei5.dni[/font] [fon...
Jacktang Microcontroller MCU
Why does AD6 suddenly need to be registered?
All the students in the corridor are using my AD6. After I sent them my copy, they suddenly needed to register it. The registration machines on the Internet are all bullshit. My version is 6.8. I don'...
zxpla PCB Design
Happiness comes from contrast???
Last night I discussed with my neighbor about his review strategy. He is not good at math, so he reviewed very quickly the first time. His basic knowledge is not solid enough, he is not familiar with ...
upc_arm Talking
Configuration of TI C64X DSP interrupt vector table (hardware interrupt)
1. Write an interrupt service routine Write an ISR function c_intXX in the .c source file for interrupt processing, such as: interrupt void c_intXX (void) { …; } Note: For hardware interrupts, XX = 00...
fish001 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1432  419  1790  165  62  29  9  37  4  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号