EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MA.01A.04.GC

Description
Mains Power Connector, 1A, 250VAC, Male
CategoryThe connector    The connector   
File Size123KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MA.01A.04.GC Overview

Mains Power Connector, 1A, 250VAC, Male

F.MA.01A.04.GC Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
Other featuresSTANDARD: IEC 60320
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceNO
MIL complianceNO
Power Connector Ratings1A, 250VAC
Manufacturer's serial numberF.MA
OptionsGENERAL PURPOSE
Total number of contacts1
IEC Inlet Filters
With fuse holders and mains switch
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus a unipolar or bipolar
rocker switch.
Designed for use in business, consumer and medical equipment,
VDU’s, vending machines and many other general purpose
applications.
F.MA-F.MB-F.MC-F.MD
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Unipolar or bipolar rocker switch
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
1 (F.MA-F.MC) or 2 (F.MB-FMD) fuse holders for
fuses 5 x 20mm (IEC) or 6.3 x 32mm (US),
unipolar (F.MA-F.MB) or bipolar (F.MC-F.MD)
rocker switch;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 4.8 x 0.8mm for rocker switch terminals;
ground terminal connected to case.
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
07 = Fuse 5 x 20mm
14 = Fuse 6.3 x 32mm
A = 1 Fuse + unipolar rocker switch
B = 2 Fuses + unipolar rocker switch
C = 1 Fuse + bipolar rocker switch
D = 2 Fuses + bipolar rocker switch
F.MA.
F.MC.
F.MD.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MB. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MA.01A.01.07.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Rocker switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
6(4)A / 250Vac (Rated current),
50000 on-off operations;
10(4)A / 250Vac (Rated current),
10000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Leakage current (I
L
):
at 220V, 50Hz, max value
Approvals
27
Based on msp430g2553 breathing light program
#include void BreathLED() {P1SEL =BIT6;P1DIR = BIT6;P1OUT=0;TACTL = TASSEL_1 + MC_1;TACCTL1 =OUTMOD_3 ;TACCTL0 = CCIE;CCR0 =12000;CCR1 =327;//0% pwmTACTL |=TACLR;_EINT(); }int main( void ) {// Stop wa...
fish001 Microcontroller MCU
【Uncle T's Library】 Love Making 32 Volumes 1.67G~~~
{:1_102:}The Fall in Love with Making series of books is here~~Forum friends who like DIY, please have a look~~ [size=5][color=magenta][b]Note: There are separate volumes that must be downloaded toget...
tyw Robotics Development
Integrated network energy communication room
Southwest Communications Metropolitan Interconnect Center (IXC) and Data Center (IDC) are the first local Internet exchange centers in China, with a total investment of more than 30 million yuan. As t...
zbz0529 Power technology
What are the differences between Android 2.3.1, 2.3.4, 2.3.5, 2.3.6, and 2.3.7?
[b][color=#cc0000]RT[/color][/b] What are the differences between so many versions? I have tried the kernel and they can all share the same kernel. I feel that android2.3.7 is not that fast and is mor...
Wince.Android Embedded System
Deploy wireless IP voice transmission using Wi-Fi mesh network
Voice is the “killer app” for wireless data networks. And high-performance Wi-Fi mesh systems are the killer IP wireless networks. However, not all mesh networks are created equal. As wireless mesh ne...
xtss RF/Wirelessly
Sound Level Meter MASTECH MS6700 Disassembly Pictures and Information
Product informationDisassembly picture:Device Analysis:Data Sheet:...
littleshrimp Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1130  1028  322  1422  1671  23  21  7  29  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号