EEWORLDEEWORLDEEWORLD

Part Number

Search

RTBH361BCSADD63K6025S

Description
ROTARY CODED SWITCH-24POSITIONS, DIRECT AND COMPLEMENT, LATCHED, PANEL MOUNT-THREADED, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size357KB,6 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

RTBH361BCSADD63K6025S Overview

ROTARY CODED SWITCH-24POSITIONS, DIRECT AND COMPLEMENT, LATCHED, PANEL MOUNT-THREADED, ROHS COMPLIANT

RTBH361BCSADD63K6025S Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
body width17.78 mm
body height21.2 mm
Body length or diameter21 mm
Contact (AC) maximum rated R load.25A@20VAC
Maximum contact current (AC)0.25 A
Maximum contact voltage (AC)20 V
Electrical life25000 Cycle(s)
Graduation angle36 deg
JESD-609 codee4
Manufacturer's serial numberRTBH
Installation featuresPANEL MOUNT-THREADED
Number of positions24
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDIRECT AND COMPLEMENT
Switch typeROTARY CODED SWITCH
Terminal surfaceSilver (Ag)
Termination typeSOLDER
C&K RTBH Series
1-2 Pole Coded Rotary Switches
Features/Benefits
Totally sealed
Detent angles, 15 , 22.5 , 30 and 36
Multi pole
Coding functions
Robust construction
Specifications
CONTACT RATING: S Contact material: Switch: 250mA, 5VA
resistive load. Carry: 5 AMPS
ELECTRICAL LIFE: Up to 25,000 operations.
OPERATING TORQUE: 5Ncm±30% (with 1 module).
MECHANICAL STOP RESISTANCE: > 70 Ncm.
BUSHING MOUNTING TORQUE: 100 Ncm.
CONTACT RESISTANCE: < 100 mΩ.
INSULATION RESISTANCE: > 109
DIELECTRIC STRENGTH: 500 V rms.
Typical Applications
Telecommunications
Military
Instrumentation
Heavy-duty industrial equipment
Materials
HOUSING: PBT thermoplastic and PC thermoplastic
STATIONARY CONTACTS & TERMINALS: Nickel alloy, gold or
silver plated, insert molded in PBT thermoplastic.
ROTOR: Printed circuit, gold or silver plated.
ACTUATOR: Steel
BUSHING: Brass
HARDWARE: Stop pin and spring: Stainless steel
All models are RoHS compliant and compatible.
NOTE:
For the latest information regarding RoHS compliance, please go to:
www.ittcannon.com/rohs.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages L-27 thru L-31. For additional options not shown in catalog, consult Customer Service Center.
L
Rotary
Designation
RTBH
Indexing
15
15°
22.5
22.5°
30
30°
36
36°
Number of Switch
Functions**
1
1 Function
2
2 Functions
Switch Function
Number of Poles (first digit)
Maximum Position (second & third digit)
or code (binary code = B, complement = C,
direct +complement = BC)
Stops
B
Binary code
B
Stop with number of positions
116
22.5 index, SP, 16 positions
S
Without
112
30 index, SP, 12 positions
Mounting Style
206
DP, 6 positions
AD
Standard bushing for panel mount
C
Complement
DE
Sealed bushing for panel mount
BC
Direct + complement
Shaft Diameter
D6
6 mm (.236)
D63
6.35 mm (.250)
Option of Shaft
(NONE)
M10X5
Shaft with flat
Actuator Option Angle*
(NONE)
K0
0° angle
Actuator Length
K60
60° angle
25
25 mm (.984)
K90
90° angle
Contact Material
K120
120° angle
S
Silver plated
K180
180° angle
G
Gold plated
K270
270° angle
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
* Other angles available by request
** Several functions can be combined. For more information consult us.
L–26
www.ittcannon.com
How to output A3 schematics using smart pdf in Altium Designer?
How to output A3 schematics using smart pdf in Altium Designer?...
zsygyx PCB Design
One question to test your analog circuit level!!!
If you want to test your analog circuit skills, please go to [url=http://group.ednchina.com/332/]http://group.ednchina.com/332/[/url] and try your hand at it! Beginners can also make great progress by...
galson Test/Measurement
Program problem of analog module
有这麽一段程序, LD M800 RD3A K0 K1 D3 LD M8000 DMUL D3 D505 D10 DDIV D10 K100 D15 What does it mean to divide the value in D10 by 100? Please help!...
eeleader-mcu Industrial Control Electronics
See what others have written
Why can passive filters filter? The essence of a filter's ability to filter is to select frequencies by causing reflections and losses through the construction of specific impedance characteristics. F...
btty038 Energy Infrastructure?
0
...
shinecl Embedded System
MCU exchange group number: 46824367 Welcome to join
[i=s]This post was last edited by paulhyde on 2014-9-15 09:44[/i] Exchange technology and help newcomers. Please fill in "MCU Exchange" when applying....
救火车 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 876  116  1967  1202  1365  18  3  40  25  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号