MAX63_ _ C_ A.......................................................0°C to +70°C
MAX63_ _ E_ A....................................................-40°C to +85°C
MAX63_ _ MJA ..................................................-55°C to +125°C
Storage Temperature Range ..............................-65°C to +150°C
Lead Temperature (soldering, 10s)...................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS—MAX6325
(V
IN
= +10V, I
OUT
= 0mA, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER
Input Voltage Range
Output Voltage
Output Voltage Temperature
Coefficient (Note 1)
SYMBOL
V
IN
V
OUT
TCV
OUT
MAX6325
MAX6325C_A
MAX6325E_A
MAX6325MJA
CONDITIONS
T
A
C, E, M
+25°C
C
E
M
+25°C
8V
≤
V
IN
≤
10V
Line Regulation (Note 2)
∆V
OUT
/
∆
V
IN
10V
≤
V
IN
≤
36V
C
E
M
+25°C
C
E
M
C
Sourcing: 0mA
≤
I
OUT
≤
15mA
Load Regulation (Note 2)
∆V
OUT
/
∆I
OUT
Sinking: -15mA
≤
I
OUT
≤
0mA
E
M
C
E
M
Supply Current
Trim-Adjustment Range
Turn-On Settling Time
Output Noise Voltage (Note 3)
Temperature Hysteresis
Long-Term Stability
∆V
OUT
/t
I
IN
∆V
OUT
t
ON
e
n
(Figure 1)
To ±0.01% of final value
0.1Hz
≤
f
≤
10Hz
10Hz
≤
f
≤
1kHz
(Note 4)
+25°C
C, E, M
C, E, M
+25°C
+25°C
+25°C
+25°C
+25°C
±15
±25
5
1.5
1.3
20
30
2.8
1
1
3
1
1
10
1.8
2
MIN
8
2.499
2.500
0.5
0.75
1.0
10
TYP
MAX
36
2.501
1.0
1.5
2.5
18
30
35
45
5
7
8
10
6
7
15
6
7
30
2.7
3.0
mA
mV
µs
µVp-p
µV
RMS
ppm
ppm/
1000hr
ppm/mA
ppm/V
ppm/°C
UNITS
V
V
2
Maxim Integrated
MAX6325/MAX6341/MAX6350
1ppm/°C, Low-Noise, +2.5V/+4.096V/+5V
Voltage References
ELECTRICAL CHARACTERISTICS—MAX6341
(V
IN
= +10V, I
OUT
= 0mA, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER
Input Voltage Range
Output Voltage
Output Voltage Temperature
Coefficient (Note 1)
SYMBOL
V
IN
V
OUT
TCV
OUT
MAX6341
MAX6341C_A
MAX6341E_A
MAX6341MJA
CONDITIONS
T
A
C, E, M
+25°C
C
E
M
+25°C
8V
≤
V
IN
≤
10V
Line Regulation (Note 2)
∆V
OUT
/
∆V
IN
10V
≤
V
IN
≤
36V
C
E
M
+25°C
C
E
M
C
Sourcing: 0mA
≤
I
OUT
≤
15mA
Load Regulation (Note 2)
∆V
OUT
/
∆I
OUT
Sinking: -15mA
≤
I
OUT
≤
0mA
E
M
C
E
M
Supply Current
Trim-Adjustment Range
Turn-On Settling Time
Output Noise Voltage (Note 3)
Temperature Hysteresis
Long-Term Stability
∆V
OUT
/t
I
IN
∆V
OUT
t
ON
e
n
(Figure 1)
To ±0.01% of final value
0.1Hz
≤
f
≤
10Hz
10Hz
≤
f
≤
1kHz
(Note 4)
+25°C
C, E, M
C, E, M
+25°C
+25°C
+25°C
+25°C
+25°C
±24
±40
8
2.4
2.0
20
30
4.0
1
1
3
1
1
7
1.9
2
MIN
8
4.095
4.096
0.5
0.75
1.0
10
TYP
MAX
36
4.097
1.0
1.5
2.5
18
30
35
45
5
7
8
10
6
7
9
6
7
18
2.9
3.2
mA
mV
µs
µVp-p
µV
RMS
ppm
ppm/
1000hr
ppm/mA
ppm/V
ppm/°C
UNITS
V
V
Maxim Integrated
3
MAX6325/MAX6341/MAX6350
1ppm/°C, Low-Noise, +2.5V/+4.096V/+5V
Voltage References
ELECTRICAL CHARACTERISTICS—MAX6350
(V
IN
= +10V, I
OUT
= 0mA, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER
Input Voltage Range
Output Voltage
Output Voltage Temperature
Coefficient (Note 1)
SYMBOL
V
IN
V
OUT
TCV
OUT
MAX6350
MAX6350C_A
MAX6350E_A
MAX6350MJA
CONDITIONS
T
A
C, E, M
+25°C
C
E
M
+25°C
8V
≤
V
IN
≤
10V
Line Regulation (Note 2)
∆V
OUT
/
∆V
IN
10V
≤
V
IN
≤
36V
C
E
M
+25°C
C
E
M
C
Sourcing: 0mA
≤
I
OUT
≤
15mA
Load Regulation (Note 2)
∆V
OUT
/
∆I
OUT
Sinking: -15mA
≤
I
OUT
≤
0mA
E
M
C
E
M
Supply Current
Trim-Adjustment Range
Turn-On Settling Time
Output Noise Voltage (Note 3)
Temperature Hysteresis
Long-Term Stability
∆V
OUT
/t
I
IN
∆V
OUT
t
ON
e
n
(Figure 1)
To ±0.01% of final value
0.1Hz
≤
f
≤
10Hz
10Hz
≤
f
≤
1kHz
(Note 4)
+25°C
C, E, M
C, E, M
+25°C
+25°C
+25°C
+25°C
+25°C
±30
±50
10
3.0
2.5
20
30
5.0
1
1
2
1
1
6
2.0
2
MIN
8
4.999
5.000
0.5
0.75
1.0
10
TYP
MAX
36
5.001
1.0
1.5
2.5
18
30
35
45
5
7
8
10
6
7
9
6
7
15
3.0
3.3
mA
mV
µs
µVp-p
µV
RMS
ppm
ppm/
1000hr
ppm/mA
ppm/V
ppm/°C
UNITS
V
V
Note 1:
Temperature coefficient is measured by the box method; i.e., the maximum
∆V
OUT
is divided by
∆T
x V
OUT
.
Note 2:
Line regulation (∆V
OUT
/ (V
OUT
x
∆
VIN
)) and load regulation (∆V
OUT
/ (V
OUT
x
∆I
OUT
)) are measured with pulses and do not
include output voltage changes due to die-temperature changes.
I was in a rush to deliver goods. I didn’t have time for the sample. I just made a small batch and poured copper. I made a mistake in a hurry. The ground terminal of the Kelvin sampling was poured. Wh...