EEWORLDEEWORLDEEWORLD

Part Number

Search

800-009-06ZNU7-10GZ

Description
Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size160KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

800-009-06ZNU7-10GZ Overview

Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Plug,

800-009-06ZNU7-10GZ Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE
Shell materialALUMINUM ALLOY
Housing size7
Termination typeCRIMP
Total number of contacts10
A
B
C
Series 800 Plug Connector
D
E
F
G
H
J
K
L
800-009
Knurled Round
Plug with
Accessory
Thread
M
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Plug Connectors
Compact Size
saves space and
weight. Smaller than other Series 80
plugs, these Series 800 plugs are
suitable for hostile environments and
are watertight when mated.
Two Shell Styles:
Integral platform for
direct shield attachment using
BAND-
IT
®
termination system, or accessory
thread for attaching a strain relief.
Crimp, Rear Release
contact system,
now with #12 and #16 M39029 coaxial
or power contacts.
Two Coupling Nut Styles:
Hex nut
or round knurled nut. Either style is
available with optional wave spring
which helps to prevent the nut from
backing off.
HOW TO ORDER
Sample Part Number
800-006
Series
-06
Shell Style
-06
Standard
Coupling Nut
M
Shell Material / Finish
C
7-10
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes to
specify these contacts:
Z
Shell Key
Position
N
Normal
800-006
Hex Plug with
Banding Platform
-16
Coupling Nut
with Anti-
Decoupling
Wave Spring
800-007
Hex Plug with
Accessory
Thread
5-3
Aluminum / Black Anodize
6-1
M
6-4
Aluminum / Electroless
6-7
Nickel
7-1
NF
7-10
Aluminum / Cadmium with
8-13
Olive Drab Chromate
9-4
ZN
9-19
Aluminum / Zinc-Nickel with
10-26
Olive Drab Chromate
12-2
ZNU
12-37
Aluminum / Zinc-Nickel with
Black Chromate
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Z
Pos. Z
Z1
Stainless Steel / Passivated
Special contacts for
#26 to #30 AWG are
also available. Use the
#23 contacts are packaged following contact codes to
specify these contacts:
with connectors. #16 and #12
contacts must be ordered
G
separately.
Pin
800-008
Knurled Round
Plug with Band
Platform
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-4
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Functions of common PIC series 8-bit microcontroller chip pin symbols
Functions of common PIC series 8- bit microcontroller chip pin symbols...
rain Microchip MCU
Partial Discharge in Switching Power Supplies
Author: Wu Tangshun and Shi Sanbao, Application Engineer, Industrial Semiconductor, Infineon Technologies1. Partial discharge phenomenonThe partial discharge (PD) phenomenon usually refers to the disc...
okhxyyo Power technology
CN0218: 500 V Common Mode Voltage Current Monitor
[b][size=5]Circuit Notes (details of the design): [/size][/b] [size=4][b]Advantages and Features[/b]: [/size] 0 to 500 V common-mode voltage Single supply voltage Galvanic isolation protects the proce...
nmg ADI Reference Circuit
USB Device Driver Development Basics - Teacher Feng from Wuhan Huaqian
[media=x,500,375]http://v.youku.com/v_show/id_XNjA1Mjk1MjY4.html[/media]...
whhqhot Embedded System
What is the variable value when Keil is running?
Hello everyone: I recently used KEIL V3 to run a code. I set a breakpoint and used the Run command to run to the breakpoint. I want to see the specific values of each variable at the breakpoint. How c...
bawgijfd Embedded System
IIC problem help
When communicating with MPU6050, the error statement I2caRegs.I2CSAR = msg->SlaveAddress; is displayed during compilation: #135 expected a filed name. What should I do? Please advise...
550507666 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1058  1721  1445  1203  1373  22  35  30  25  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号