Pressure Transmitter
With Current Output (2-wire)
PT9V-2004-I2-H1141/X
■
Completely welded measuring cell
■
Compact and robust design
■
Excellent EMC properties
■
Pressure range -1…9 bar rel.
Wiring Diagram
Type designation
Ident-No.
Pressure range
Relative pressure
PT9V-2004-I2-H1141/X
6836105
Admissible overpressure
Burst pressure
Response time
Long-term stability
Power supply
Operating voltage
Current consumption
Short-circuit/reverse polarity protection
Protection type and class
Insulation voltage
Outputs
Output 1
Analog output
Current output
Load
Accuracy LHR analog output
Temperature behaviour
Medium temperature
Temperature coefficient
Ambient conditions
Ambient temperature
Storage temperature
Vibration resistance
Shock resistance
-1…9 bar rel.
-14.5…130.5 psi
-0.1…0.9 MPa
ð
30 bar
ï
60 bar
< 2 ms, typ. 1 ms
0.25% FS, , acc. to EN 60770-1
Functional principle
The pressure sensors of the PT …-2000 se-
ries operate with a fully welded metal measur-
ing cell. Depending on the sensor type used,
the processed signal is available as analog
output of either 4…20 mA (2-wire) or 0…10 V
(3-wire).
7…33 VDC
ð
23 mA
yes / yes
IP67 / III
750 VDC
Analog output
4…20 mA
ð
(Supply voltage -7)/20 kò
± 0.3 % FS BSL
-40…+135 °C
± 0.2 % of full scale/10 K
-30…++85 °C
-50…+100 °C
20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
mm acc. to IEC 68-2-6
100 g, 11 ms, half sinusoidal curve, all 6 directions,
free fall from 1 m onto concrete (6x) , according to
IEC 61508
Edition • 2018-05-22T17:18:54+02:00
Housing
Housing material
Pressure connection material
Pressure transducer material
Sealing material
Process connection
Wrench size pressure connection / coupling nut
Electrical connection
Max. tightening torque housing nut
1/2
Stainless-steel/Plastic, Stainless steel V4A (1.4404)/
Polyacrylamide 50% GF UL 94 V-0
Stainless steel V4A (1.4404)/AISI 316L
Stainless steel 1.4016 / AISI 430
FPM
G¼" male thread
SW 24
Connectors, M12 × 1
20 Nm
TURCK Inc.
ñ
3000 Campus Drive Minneapolis, MN 55441-2656
ñ
Phone: 763-553-7300
ñ
Application Support: 1-800-544-7769
ñ
Fax 763-553-0708
ñ
www.turck.com
Pressure Transmitter
With Current Output (2-wire)
PT9V-2004-I2-H1141/X
Reference conditions acc. to IEC 61298-1
Temperature
Atmospheric pressure
Humidity
Auxiliary power
MTTF
15…+25 °C
860…1060 hPa abs.
45…75 % rel.
24 VDC
1189 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-05-22T17:18:54+02:00
2/2
TURCK Inc.
ñ
3000 Campus Drive Minneapolis, MN 55441-2656
ñ
Phone: 763-553-7300
ñ
Application Support: 1-800-544-7769
ñ
Fax 763-553-0708
ñ
www.turck.com