EEWORLDEEWORLDEEWORLD

Part Number

Search

PT9V-2004-I2-H1141/X

Description
Peizoresistive Sensor,
CategoryThe sensor    Sensor/transducer   
File Size157KB,2 Pages
ManufacturerTURCK Inc.
Websitehttps://www.turck.us/
Download Datasheet Parametric View All

PT9V-2004-I2-H1141/X Overview

Peizoresistive Sensor,

PT9V-2004-I2-H1141/X Parametric

Parameter NameAttribute value
MakerTURCK Inc.
Reach Compliance Codeunknown
Other featuresIP67; REVERSE POLARITY PROTECTION; SHORT CIRCUIT PROTECTION
body height60.8 mm
Body length or diameter24 mm
shellSTAINLESS STEEL
Maximum working current23 mA
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
Output interface type2-WIRE INTERFACE
Output range4-20mA
Output typeANALOG OUTPUT
Package Shape/FormCYLINDRICAL
port type1/4G
Maximum pressure range130.5 Psi
Minimum pressure range-14.5 Psi
Pressure sensing modeRELATIVE
Response time1000 µs
Sensor/Transducer TypePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage33 V
Minimum supply voltage7 V
Termination typeCONNECTOR
Pressure Transmitter
With Current Output (2-wire)
PT9V-2004-I2-H1141/X
Completely welded measuring cell
Compact and robust design
Excellent EMC properties
Pressure range -1…9 bar rel.
Wiring Diagram
Type designation
Ident-No.
Pressure range
Relative pressure
PT9V-2004-I2-H1141/X
6836105
Admissible overpressure
Burst pressure
Response time
Long-term stability
Power supply
Operating voltage
Current consumption
Short-circuit/reverse polarity protection
Protection type and class
Insulation voltage
Outputs
Output 1
Analog output
Current output
Load
Accuracy LHR analog output
Temperature behaviour
Medium temperature
Temperature coefficient
Ambient conditions
Ambient temperature
Storage temperature
Vibration resistance
Shock resistance
-1…9 bar rel.
-14.5…130.5 psi
-0.1…0.9 MPa
ð
30 bar
ï
60 bar
< 2 ms, typ. 1 ms
0.25% FS, , acc. to EN 60770-1
Functional principle
The pressure sensors of the PT …-2000 se-
ries operate with a fully welded metal measur-
ing cell. Depending on the sensor type used,
the processed signal is available as analog
output of either 4…20 mA (2-wire) or 0…10 V
(3-wire).
7…33 VDC
ð
23 mA
yes / yes
IP67 / III
750 VDC
Analog output
4…20 mA
ð
(Supply voltage -7)/20 kò
± 0.3 % FS BSL
-40…+135 °C
± 0.2 % of full scale/10 K
-30…++85 °C
-50…+100 °C
20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
mm acc. to IEC 68-2-6
100 g, 11 ms, half sinusoidal curve, all 6 directions,
free fall from 1 m onto concrete (6x) , according to
IEC 61508
Edition • 2018-05-22T17:18:54+02:00
Housing
Housing material
Pressure connection material
Pressure transducer material
Sealing material
Process connection
Wrench size pressure connection / coupling nut
Electrical connection
Max. tightening torque housing nut
1/2
Stainless-steel/Plastic, Stainless steel V4A (1.4404)/
Polyacrylamide 50% GF UL 94 V-0
Stainless steel V4A (1.4404)/AISI 316L
Stainless steel 1.4016 / AISI 430
FPM
G¼" male thread
SW 24
Connectors, M12 × 1
20 Nm
TURCK Inc.
ñ
3000 Campus Drive Minneapolis, MN 55441-2656
ñ
Phone: 763-553-7300
ñ
Application Support: 1-800-544-7769
ñ
Fax 763-553-0708
ñ
www.turck.com
Poll: What operating system are you using now? (Thank you for participating)
[i=s] This post was last edited by lcofjp on 2017-10-15 15:39 [/i] I am currently writing a serial port application software, which is mainly for electricians. However, this software does not support ...
lcofjp Embedded System
Findfirstfile traversal file problem
I found an example online. It always has to check strcmp(fd.cFileName, ".") && strcmp(fd.cFileName, ".."). What is this used to judge?...
heeroz Embedded System
SYMBOL data collector (MC1000) crash problem
Hello everyone, my question is, why does the MC1000 program I made freeze after scanning about 10 bars? What caused the error? I'm offering RMB 200 to seek the answer. If anyone knows or can solve my ...
szgaoju Embedded System
ADS1291 is used as the ECG acquisition and conversion front end, and the data conversion problems encountered
Recently, I am working on an ECG data acquisition project, using ADS1291 as an analog-to-digital converter. During the test, I found that there is a problem with the converted data: After the analog E...
Maxweller_Wang TI Technology Forum
Today is a special day
Today is a special day. One thing is that I met an online friend of mine for 6 or 7 years (never met in person). We have been in touch on QQ before and both work in Beijing. We have always wanted to g...
wateras1 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1559  990  1586  1799  803  32  20  37  17  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号