Description
Electric Fuse, 600A, 600VAC, 10000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size273KB,4 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

NOS-600 Online Shopping

Suppliers Part Number Price MOQ In stock  
NOS-600 - - View Buy Now

NOS-600 Overview

Electric Fuse, 600A, 600VAC, 10000A (IR), Inline/holder

NOS-600 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerCooper Industries
Reach Compliance Codecompliant
body height339.85 mm
Body length or diameter79.5 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberNOS
Installation featuresINLINE/HOLDER
method of packingBOX
physical size79.5mm x 339.85mm
Rated breaking capacity10000 A
Rated current600 A
Rated voltage (AC)600 V
GuidelineCE; CSA; UL
surface mountNO
Terminal shapeTAB/BLADE
NON/NOS, 600/250Vac Class K5 & H
NON (250V)
1
8
-600A, General Purpose Fuses
Dimensions – in
All Diameters ± 0.008
2"
(0.031)
0.56" (± 0.008)
1/8 to 30A
3"
(0.031)
0.81" (± 0.008)
35 to 60A
5.88" (± 0.062)
1.06"
70 to 100A
110 to 200A
225 to 400A
7.13" (± 0.062)
1.56"
450 to 600A
8.63" (± 0.094)
2.06"
10.38" ( 0.094)
2.59"
Description:
Basic protection 250V NON Class K5 and H
general purpose, non-current-limiting, one-time fuses.
Catalog Symbol:
NON-(amp)
Ratings:
Volts — 250Vac
— 125Vdc (
1
8
-100A)
Amps —
1
8
-600A
IR — 50kA Vac RMS Sym. (
1
8
-60A)
— 10kA Vac RMS Sym. (65-600A)
— 50kA Vdc (
1
8
-60A)
— 10kA Vdc (65-100A)
Agency Information:
CE, UL Listed, Class K5 (
1
8
-60A), Std. 248-9,
Class H (65-600A), Std. 248-6 (125Vdc
1
8
-100A),
UL Guide JDDZ, File E4274
CSA Certified, Class 1421-01, File 53787 (
1
8
-12A, 65-600A)
† For CSA Certified 15-60A, see PON Data Sheet # 4126.
Features:
• Protect lighting, heating and other circuits not subject to temporary
surges and where available short-circuit currents are relatively low
• NON one-time fuses do not have any appreciable degree of time-
delay and thus should
not
be specified in circuits where large
transients or motor overloads occur. Use Bussmann advanced
protection FUSETRON™ FRN-R or ultimate protection Low-Peak™
LPN-RK dual-element, time-delay fuses.
• For general purpose circuits, size at amp rating of circuit
• For motor circuits, size at 300% to 400% according to the NEC
®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Recommended Fuse Blocks
Fuse Amps
0-30
35-60
70-100
110-200
225-400
450-600
1-Pole
H25030-1
H25060-1
HM25100-1CR
HM25200-1CR
HM25400-1CR
HM25600-1CR
Catalog Numbers (amps)
NON-
1
8
NON-
1
2
NON-
3
4
NON-
8
10
NON-1
NON-1
1
4
NON-1
1
2
NON-1
6
10
NON-2
NON-2
1
2
Amp Rating
1
8
-30
35–60
65–100
110–200
225–400
450–600
NON-3
NON-3
2
10
NON-4
NON-5
NON-6
NON-6
1
4
NON-7
NON-8
NON-9
NON-10
NON-12
NON-15
NON-20
NON-25
NON-30
NON-35
NON-40
NON-45
NON-50
NON-60
Carton Qty.
10
10
5
1
1
1
NON-65
NON-70
NON-75
NON-80
NON-90
NON-100
NON-110
NON-125
NON-150
NON-175
NON-200
NON-225
NON-250
NON-300
NON-350
NON-400
NON-450
NON-500
NON-600
2-Pole
H25030-2
H25060-2
HM25100-2CR
HM25200-2CR
HM25400-2CR
HM25600-2CR
3-Pole
H25030-3
H25060-3
HM25100-3CR
HM25200-3CR
HM25400-3CR
HM25600-3CR
For additional information on 250 volt fuse blocks, see Data
Sheet # 1112 (H250) and product brochure # 3192 (HM Se-
ries).
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
60A
100A
200A
200A
400A
Desired Fuse
(Case) Size
30A
30A
60A
60A
100A
100A
200A
Catalog Numbers
(Pairs) 250V
NO.263
NO.213
NO.216
NO.226
NO.2621
NO.2641
NO.2642
Carton Quantity and Weight
For additional information on Class K5 & H fuse reducers, see
Data Sheet # 1118.
0713
BU-SB13738
Page 1 of 4
Data Sheet # 1030
Introduce a few introductory books, scattered points~~~
I am writing drivers on a microcontroller. Last time, I encountered a problem of writing USB drivers on a PC, but I didn't understand it at all. I have some basic knowledge of VC. Now I want to learn ...
cindy99 Embedded System
Selection of automatic fire alarm wires and wiring issues
2.1 Wire selection 2.1.1 Wire model For the wires of the signal transmission line and linkage control line of the automatic fire alarm system, fire-resistant wires or cables are selected in many desig...
jek9528 Industrial Control Electronics
Help; Is there anyone who has connected a development board to an IP camera?
I am going to make a car-mounted high-definition video surveillance system recently. The camera is about 5 meters away from the cab, and the transmission line is about 7 meters long. The image resolut...
ddnerve01 Embedded System
Schematic diagram of weight scale
Does anyone have the schematic diagram and PCB package of the electronic weight scale? ? :Cry:...
鹿洋yy PCB Design
Happy Spring Festival
[b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]dcexpert[/size]. If you want to reprint or use it for commercial purposes, you must obtain the author's consent and i...
dcexpert MicroPython Open Source section
CC1310 demo RX WOR power consumption issue
I just burned the WOR program of TI CC1310 demo RX and found that the current increased to 6.5mA instantly and then dropped back down. Why does this happen?...
study-xianbing Wireless Connectivity

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2292  61  1796  699  1849  47  2  37  15  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号