EEWORLDEEWORLDEEWORLD

Part Number

Search

8504K56

Description
Toggle Switch, DP3T, Latched And Momentary, 20A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded
CategoryMechanical and electronic products    switch   
File Size157KB,4 Pages
ManufacturerEaton
Download Datasheet Parametric View All

8504K56 Overview

Toggle Switch, DP3T, Latched And Momentary, 20A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded

8504K56 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeLOCKING LEVER
body width23.11 mm
body height31.5 mm
Body length or diameter34.04 mm
Contact (AC) maximum rated R load15A@115VAC
Maximum contact current (AC)15 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life20000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature71 °C
Minimum operating temperature-65 °C
sealENVIRONMENTALLY SEALED
surface mountNO
Switch actionLATCHED AND MOMENTARY
switch functionDP3T
Switch typeTOGGLE SWITCH
Termination typeSCREW
MILITARY—ENVIRONMENTALLY SEALED SWITCHES
Series—8503, 8504, 8505
MIL-S-3950 Lever Lock Switches
FEATURES
• Environmentally sealed
• 1, 2, and 4 pole circuitry
• 2 & 3 position with maintained and
momentary action
• Locking actuator for safety
• Molded-in terminal inserts and terminal
numbers
SPECIFICATIONS
• Environmentally sealed per MIL-S-3950
• MS approved and QPL’d per MIL-S-3950
• Thermoset molding materials meet flame
retardant requirements of
• Bushing: 15/32" - 32 thread
• Temperature Range: -85°F to +160°F
(-65°C to +71°C)
• Life: 20,000 operations at rated load
40,000 operations mechanical life
CURRENT RATINGS
No. of Catalog
Type of
Poles Number Operation
28VDC
Lamp Resistive Inductive
Load
Load
Load
5
20
15
4
15
10
7
20
15
5
18
10
5
20
12
4
18
10
115VAC
60 or 400Hz
Lamp Resistive Inductive
Load
Load
Load
3
15
10
2
15
7
4
15
15
2
11
8
4
15
15
2
11
8
1
2
4
8503
8504
8505
Maintained
Momentary
Maintained
Momentary
Maintained
Momentary
Minimum Rating: “Intermediate Current” per MIL-S-3950
LEVER LOCK SELECTION T ABLE
8503
CIRCUIT WITH LEVER IN...
Up
Position
Center
Position
Down
Position (Keyway)
Lever
x
Lock
Bushing
Style
A
B
D
E
F
G
H
J
K
L
M
N
P
D
F
G
D
F
G
E
F
K
M
F
F
E
L
N
E
F
F
E
F
K
L
8504
TWO POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
MS24659-21A
-21B
-21D
-21E
-21F
MS24659-21G
-21H
-21J
-21K
-21L
MS24659-21M
-21N
-21P
-22D
-22F
MS24659-22G
-23D
-23F
-23G
-24E
MS24659-24F
-24K
-24M
-25F
-26F
MS24659-27E
-27L
-27N
-28E
-29F
MS24659-30F
-31E
-31F
-31K
-31L
8504K1
K27
K5
K2
K28
8504K3
K29
K30
K31
K32
8504K33
K4
K34
K10
K35
8504K9
K6
K36
K7
K16
8504K37
K38
K11
K22
K20
8504K12
K39
K14
K15
K21
8504K19
K18
K40
K41
K13
8505
FOUR POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
MS24660-21A
-21B
-21D
-21E
-21F
MS24660-21G
-21H
-21J
-21K
-21L
MS24660-21M
-21N
-21P
-22D
-22F
MS24660-22G
-23D
-23F
-23G
-24E
MS24660-24F
-24K
-24M
-25F
-26F
MS24660-27E
-27L
-27N
-28E
-29E
MS24660-30F
-31E
-31F
-31K
-31L
8505K1
K27
K5
K2
K28
8505K3
K29
K30
K31
K32
8505K33
K4
K34
K10
K35
8505K9
K6
K36
K7
K16
8505K37
K38
K11
K22
K20
8505K12
K39
K14
K15
K21
8505K19
K18
K40
K41
K13
ONE POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
MS24658-21A
-21B
-21D
-21E
-21F
MS24658-21G
-21H
-21J
-21K
-21L
MS24658-21M
-21N
-21P
-22D
-22F
MS24658-22G
-23D
-23F
-23G
-24E
MS24658-24F
-24K
-24M
-25F
-26F
MS24658-27E
-27L
-27N
-28E
-29F
MS24658-30F
-31E
-31F
-31K
-31L
8503K1
K27
K5
K2
K28
8503K3
K29
K30
K31
K32
8503K33
K4
K34
K10
K35
8503K9
K6
K36
K7
K16
8503K37
K38
K11
K22
K20
8503K12
K39
K14
K15
K21
8503K19
K18
K40
K41
K13
*
*
*
ON§
ON
ON§
ON
ON§
ON
ON§
ON
ON§
ON
ON§
ON
ON
ON§
ON§
ON
ON§
ON§
ON
ON
ON§
ON§
ON§
ON§
ON§
ON
ON
ON
NONE
ON§
OFF§
ON
ON§
ON§
ON
OFF§
OFF§
OFF
OFF§
OFF
OFF
OFF§
OFF
OFF§
OFF§
OFF
OFF
OFF§
NONE
NONE
NONE
NONE
NONE
NONE
OFF
OFF
OFF§
OFF
OFF
NONE
OFF§
OFF§
OFF
OFF§
NONE
NONE
OFF§
OFF
OFF§
OFF§
*
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
ON
ON
NONE
NONE
NONE
NONE
NONE
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
*
*
*
*
*
*
*
*
*
*
*
Moment ry contact.
*
Indicatesadirection against which lever is locked.
§
See page 73 for circuit diagrams.
x
Reference bushing styles on Page 34.
The baud meter of multisim shows nothing
The Bode meter does not display any graph. According to the requirements, the center frequency is 2K HZ, the bandwidth is 200HZ, and the gain is 20. No matter how I adjust it, the Bode graph is nothin...
dodwww Analogue and Mixed Signal
Book: Lao Mei's "Electronic Filter Design"
...
ddllxxrr Analog electronics
Linear optocoupler isolation amplifier
Linear optocoupler isolation amplifier...
fighting Analog electronics
Do you have enough psychological endurance?
This set of pictures is called [b] Human Ultimate Edition[/b] [size=5][color=#00ff00] If you don’t have enough psychological endurance, please don’t click randomly, otherwise if something happens, it ...
yaoyong Talking
PCB design software Protel 99 SE and AD copper-free hole and copper-free slot design
Protel 99 SE and AD copper-free hole and copper-free slot design intuitive approach 1: Picture analysis, the pad wants to be made into a copper-free hole, but the pad is needed. Ask, why does the circ...
dengguoqiang PCB Design
[TI's First Low Power Design Competition] First Test of SHARP96 Memory Screen
[i=s]This post was last edited by qiushenghua on 2014-10-14 17:13[/i] I applied for samples from TI before, and then TI shared the information with the agent Shenzhen Xinye. Their application engineer...
qiushenghua Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2654  1556  1332  748  2381  54  32  27  16  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号