78P2344JAT-IGTR

Description
PCM Transceiver, 1-Func, PQFP100, TQFP-100
CategoryWireless rf/communication    Telecom circuit   
File Size389KB,36 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

78P2344JAT-IGTR Online Shopping

Suppliers Part Number Price MOQ In stock  
78P2344JAT-IGTR - - View Buy Now

78P2344JAT-IGTR Overview

PCM Transceiver, 1-Func, PQFP100, TQFP-100

78P2344JAT-IGTR Parametric

Parameter NameAttribute value
MakerTDK Corporation
Parts packaging codeQFP
package instructionLFQFP,
Contacts100
Reach Compliance Codeunknown
JESD-30 codeS-PQFP-G100
length14 mm
Number of functions1
Number of terminals100
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package body materialPLASTIC/EPOXY
encapsulated codeLFQFP
Package shapeSQUARE
Package formFLATPACK, LOW PROFILE, FINE PITCH
Certification statusNot Qualified
Maximum seat height1.6 mm
Nominal supply voltage3.3 V
surface mountYES
Telecom integrated circuit typesPCM TRANSCEIVER
Temperature levelINDUSTRIAL
Terminal formGULL WING
Terminal pitch0.5 mm
Terminal locationQUAD
width14 mm
78P2344JAT
4-port E3/DS3/STS-1 LIU
with Jitter Attenuator
PRELIMINARY DATASHEET
JULY 2003
DESCRIPTION
The 78P2344JAT is a low-power, 4-port
DS3/E3/STS1 Line Interface Unit (LIU) with
integrated Jitter Attenuator (JAT). It includes clock
recovery and transmitter pulse shaping functions for
applications using 75-ohm coaxial cable at distances
up to 1350 feet. These applications include
DSLAMs, T1,3/E1,3 digital multiplexers, SONET
Add/Drop multiplexers, PDH equipment, DS3 to
Fiber optic and microwave modems and ATM WAN
access for routers and switches.
The receiver recovers clock and data from a B3ZS
or HDB3 coded AMI signal. It can compensate for
over 12dB of cable and 6dB of flat loss. The
transmitter generates a signal that meets the
standard pulse shape requirements.
It has a
B3ZS/HDB3 ENDEC with a receive line code
violation detector, a loop-back mode, an input
receive MUX that can select a redundant channel, a
clock polarity selection mode, and the ability to
receive a DSX3 monitor signal.
FEATURES
Transmit and receive interfaces for E3, DS3 and
STS-1 applications
Designed for use with 75 ohm coaxial cable up
to 1350 ft long end-to-end or up to 900 ft long
from a DS3 cross-connect
Receives DS3-high and DSX3 monitor signals
Local and Remote loopback
Selectable B3ZS/HDB3 ENDEC with line code
violation detector
Standards-based LOS function
Optional serial-port based mode selection and
channel status monitoring
Receiver AGC corrects for up to 6dB of flat loss
Adaptive digital clock recovery (uses line-rate
reference clock input)
Receive output clock maintains nominal line-rate
frequency at all times
Fully integrated Jitter Attenuation function
provided for all line rates (no external VCXO
required)
Jitter Attenuator configurable for transmit or
receive path
Transmit line fault monitor
Requires no external current-setting resistor or
loop filter components
Single 3.3V supply operation
Available in 100-pin Exposed Pad JEDEC LQFP
STANDARDS
Jitter Tolerance: Telcordia GR-499-CORE [DS3]
and GR-253-CORE [STS1], ITU-T G.823 [E3]
and G.824 [DS3]
Loss of Signal: ITU-T G.775
Jitter Transfer: ETSI TBR-24 1997 [E3];
Telcordia GR-499-CORE [DS3] and GR-253-
CORE [DS3/STS1]
BLOCK DIAGRAM
Controls
Flags
RLBK
LBO E3 DS3
TXEN
TPOS
TNEG
TCLK
Jitter
Attenuator
RPOS
RNEG
RCLK
B3ZS /
HDB3
Decoder
B3ZS /
HDB3
Encoder
Transmit
Monitor
TXNW
Pulse
Shaper
LOUTP
LOUTN
Attenuator
ENDEC
Data
Detector
Adaptive
Equalizer
AGC
LINP
LINN
MON
TCLKP
RCLKP
Power
Distribution
Clock
Recovery
Signal
Detector
LLBKA
LLBKB
Signals from
Adjacent Port
CS
SCK
SDI
SDO
Control
Registers
LOS
PDTX PDRX
CKREF
Each Channel
Master
Bias
Generator
CKREF
-1-
After J-LINK downloads the program, the program is gone when the power is turned off and then on again.
After J-LINK downloads the program, I unplug the J-LINK when the power is turned off, and then power it on again, but the program is gone. I have to download it again. . . If I don't unplug the J-LINK...
oneofzero stm32/stm8
The live broadcast has ended [ADI Voice Interaction System Solution]
[font=微软雅黑][size=3][b][color=#4b0082]Event details: [/color][/b][url=https://www.eeworld.com.cn/a17346]Rewarded broadcast registration [ADI Voice Interaction System Solution] [/url] [b][color=#4b0082]...
EEWORLD社区 ADI Reference Circuit
What is the relationship between the totem pole circuit and the push-pull circuit?
What is the relationship between the totem pole circuit and the push-pull circuit? It seems that the circuit form is the same. This is the first time I heard this statement, so I would like to ask you...
wstt Analog electronics
Compilation error
A simple program has a compilation error: cant open file sample.obj for input.Why?I am using 2407a and your XDSUSB emulator. I heard that I need to put a file called rts2000.lib in the program directo...
lilove751 Analogue and Mixed Signal
How can I obtain the number of bytes or frames sent or received by the network card under WinCE?
I use NDISUIO's IOCTL_NDISUIO_QUERY_OID_VALUE to read OID_GEN_DIRECTED_BTYES_RCV, but the deviceioctrol return value is 0x00000032 (request not supported)? Is there any other way to get the number of ...
h_g_y Embedded System
Did you know? Tektronix MSO6 Series oscilloscopes make it easy to characterize jitter on GHz clocks and serial buses
Easily characterize jitter on GHz clocks and serial buses with the latest Tektronix MSO6 Series oscilloscopes. Comprehensive advanced measurements make it easy to incorporate statistics into your ever...
EEWORLD社区 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2379  2795  1384  730  280  48  57  28  15  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号