EEWORLDEEWORLDEEWORLD

Part Number

Search

FS10-3600-C2-B

Description
Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT
CategoryPower management    transformer   
File Size47KB,1 Pages
ManufacturerTriad Magnetics
Websitehttps://www.triadmagnetics.com/
Environmental Compliance
Download Datasheet Parametric View All

FS10-3600-C2-B Overview

Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT

FS10-3600-C2-B Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTriad Magnetics
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Center click function 1NO
Center click function 2NO
high39.67 mm
Insulation voltage4200000 V
length66.67 mm
Installation featuresTHROUGH HOLE MOUNTED
Number of secondary windings2
Output current 13.6 A
Output current 23.6 A
Output voltage 15 V
Output voltage 25 V
method of packingBULK
physical sizeL66.67XB55.55XH39.67 (mm)
main ratingDUAL 115V
surface mountNO
Transformer typeSPLIT BOBBIN POWER TRANSFORMER
VA rating36 VA
width55.55 mm

FS10-3600-C2-B Preview

CLASS 2 TRANSFORMER
FS10-3600-C2
Description:
The FS10-3600-C2 is a series/parallel primary and dual secondary, split bobbin
design which operates with either a parallel input of 115V or a series input of 230V.
The secondaries are 5V @ 3.6A each. They can be used independently (up to
300V difference between them) or in series for double the voltage or in parallel for
double the current. The split bobbin design eliminates the need for costly
electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 36.0VA
2. Primary: Series: 230V; Parallel: 115V
3. Secondaries: 5.0V @ 3.6A each
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 4200 VRMS pri to sec
7. Hipot tested 100% at 2160 VRMS sec to sec
8. Recommended fuse (fuse on primary): For 115V - Cooper/Bussman, Type MDL,
rated 500mA, 250V. For 230V – Littlefuse, Type 313, rated 250mA, 250V
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155°C).
E
Agency File:
UL: File E65390, UL 5085-1 & 3 (1585), Class 2 Transformer
cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
TUV Certificate No.: R72120839, EN61558, Safety Isolating xfmr, general use
L
H
1
2
3
4
Dimensions:
H
W
1.562
2.187
Weight: 1.10 lbs
L
2.625
A
0.400
B
0.400
C
1.850
Units in inches.
D
0.041
E
0.020
F
0.234
D
F
A
8
Schematic:
PARALLEL
1
115V
50/60Hz
2
3
4
230V
50/60Hz
SERIES
1
2
3
4
4
1
5
5V @ 3.6A
2
3
6
7
5V @ 3.6A
8
A
5
B
C
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
1
Note:
Order and shipping documentation may have a “-B” suffix; this indicates Bulk
packaging but does not show on the actual part number marked on the transformer
.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
4
0.06" DIAMETER
HOLE
Board Layout
www.TriadMagnetics.com
Phone: (951) 277-0757
Fax: (951) 277-2757
460 Harley Knox Blvd.
Perris, CA 92571
Publish Date: December 4, 2013
[TI's first low-power design competition] MSP430FR5969 human ECG acquisition real picture
[i=s]This post was last edited by Mandy on 2015-1-2 11:27[/i] I have been quite busy recently, designing boards, adjusting circuits and writing programs. Fortunately, everything has gone smoothly. The...
Mandy Microcontroller MCU
Methods to increase the transmission distance of wireless modules
With the development of wireless data transmission, the application of wireless modules is becoming more and more extensive. Wireless modules are widely used in vehicle monitoring, remote control, tel...
成都亿佰特 Robotics Development
atj2085's sfr
Excuse me, can anyone tell me the SFR (special function register) of atj2085?...
luson Embedded System
What are the most popular automotive electronic technologies at present? ? ? ?
At present, the development direction of automotive electronic technology is towards centralized integrated control: integrating the engine management system and automatic transmission control system ...
1ying Automotive Electronics
Friends with dual-core or 4-core CPU can refer to the HFSS accelerated solution settings.
Friends with dual-core or 4-core CPU can refer to the HFSS accelerated solution settings. My friend has tried it and heard that the solving speed will really become faster! Friends with dual-core or 4...
chunhsiung RF/Wirelessly
Recruiting entrepreneurial partners for wireless communication, 2.4G, wifi module, and Bluetooth module development
Hello experts, I am a sales worker engaged in wireless communication solutions and products. I have a large number of customer resources in wireless remote control products. Based on the principle of ...
kendybusiness RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2053  868  1805  2459  514  42  18  37  50  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号