EEWORLDEEWORLDEEWORLD

Part Number

Search

RT314060

Description
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.007A (COIL), 60VDC (COIL), 420mW (COIL), 16A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size237KB,4 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

RT314060 Online Shopping

Suppliers Part Number Price MOQ In stock  
RT314060 - - View Buy Now

RT314060 Overview

POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.007A (COIL), 60VDC (COIL), 420mW (COIL), 16A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

RT314060 Parametric

Parameter NameAttribute value
Maximum operating temperature85 Cel
Minimum operating temperature-40 Cel
Processing package descriptionROHS COMPLIANT
Lead-freeYes
EU RoHS regulationsYes
China RoHS regulationsYes
stateACTIVE
sealRT2
Coil power420 mW
Relay actionMOMENTARY
Relay functionSPDT
Coil resistance8570 ohm
Electrical life6000 Cycle(s)
terminal coatingNOT SPECIFIED
Manufacturer SeriesRT1
Maximum DC coil current0.0070 A
Maximum DC coil voltage60 V
Maximum AC contact current16 A
Maximum DC contact current16 A
Maximum AC contact voltage400 V
Maximum DC contact voltage24 V
DC coil operating voltage42 V
DC coil release voltage6 V
width12.7 mm
high15.7 mm
length or diameter29 mm
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours8 ms
Relay typePOWER/SIGNAL RELAY
release time6 ms
Terminal typeSOLDER
General Purpose Relays
Power PCB Relay RT1
I
I
I
I
I
I
I
1 pole 12 / 16 A, 1 CO or 1 NO contact
DC- or AC-coil
Sensitive coil 400 mW
5 kV / 10 mm coil-contact, reinforced insulation
Ambient temperature 85°C (DC-coil)
WG version: Product in accordance to IEC60335-1
RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
Applications
F0144-B
Boiler control, timers, garage door control, POS automation,
interface modules
Approvals
V
REG.-Nr. 6106,
Z
E214025,
B
C0786,
S
0039110/01-02,
F
FI 190164 A1,
H
98.4118.01
Technical data of approved types on request
Contact data
Contact configuration
1 CO or 1 NO contact
Contact set
single contact
Type of interruption
micro disconnection
Rated current
12 A
16 A
Rated voltage / max.switching voltage AC
240/400 VAC
Limiting continuous current
UL: 20 A
Maximum breaking capacity AC
3000 VA
4000 VA
Limiting making capacity, max 4 s, df 10%
25 A
30 A
Contact material
AgNi 90/10, AgNi 90/10 gold plated
Mechanical endurance DC coil
> 30 x 10
6
cycles
AC coil
> 10 x 10
6
cycles
Rated frequency of operation with / without load
6 / 1200 min
-1
Contact
Type
RT314
RT314
RT314
RT314
RT314
RT314
RT314
RT314
RT314
RT314
RT314
ratings
Load
Cycles
16 A, 250 VAC, NO contact, 85°C, DF 10%, UL508
50x10
3
-1
16 A, 250 VAC, NC contact, 70°C, 30min
53x10
3
20 A, 250 VAC, NO contact, 85°C, UL508
6x10
3
1000 W incandescent lamp, 250 VAC
1.2x10
3
10 A, 250 VAC, cosϕ=0.6, CO contact, 70°C
200x10
3
-1
5 A / 2 A, 250 VAC, cosϕ=1, motor, NO contact, 10min , 70°C
1.1x10
6
-1
0.26 A / 0.01 A, 230 VAC, cosϕ=0.38, valve, NO contact, 25min
7.6x10
6
Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
AC15, 6 A, 250 VAC, NO and NC contact, 85°C, EN60947-5-1
DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85°C, EN60947-5-1
Coil data
Rated coil voltage range DC coil
AC coil
Coil power DC coil
AC coil
Operative range
Coil insulation system according UL1446
5...110 VDC
24...230 VAC
typ 400 mW
typ 0.75 VA
2
class F
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
If pure fuel vehicles are no longer sold in 2025, is it still necessary to buy high-priced fuel vehicles now?
A few years ago, there were rumors that the country would gradually phase out fuel vehicles by 2025. Although it was later confirmed that the rumor was false, the country could not be so radical. As v...
eric_wang Automotive Electronics
What materials are better for beginners to learn msp430?
I only have some basic knowledge of 51 and I learned it by myself but I still find it difficult to get started. Are there any good videos or books you can recommend?...
天天1 Microcontroller MCU
Ask about Linux embedded file system encryption.
Recently I encountered a problem with system encryption of a product, mainly to protect our file system. If any friends have done work in this area, please give me some advice, I would be very gratefu...
ljytl1981 Linux and Android
Liquid crystal module handling precautions and storage conditions
This content is originally created by EEWORLD forum user Rohm LCD Technology Station . If you want to reprint or use it for commercial purposes, you must obtain the author's consent and indicate the s...
罗姆液晶技术站 Integrated technical exchanges
A brief analysis of the difficulties in reliability testing of embedded system software
[size=4] At present, the reliability evaluation of embedded software mainly relies on testing, because the development environment of embedded software and the running environment of software in embed...
Jacktang DSP and ARM Processors
Understanding the configuration of C2000 series CMD files
The professional name of CMD is linker configuration file, which stores the configuration information of linker. We call it command file for short. The key is the use of two pseudo instructions, MEMOR...
Aguilera Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2546  2526  1617  2607  712  52  51  33  53  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号